Omron E2FM – Proximity Sensor with All-stainless Housing X1R/X2/X5- Series- Proximity Sensors
$ 309.81 – $ 344.77
Omron produce industrial sensors range such as fiber sensors, photoelectric sensors, displacement sensors/ measurement sensors, proximity sensors, photomicro sensors and rotary encodes.
Features
One-piece completely stainless-steel housing with a face thickness of 0.8 mm
The face thickness is approximately 4 times that of previous models (E2ES) to enable sensing in even more severe conditions than ever.
Brush Test
Continuous Impact Test
Chemical and Detergent Proof
The one-piece completely stainlesssteel housing of the sensing section withstands the following chemicals better.
• Sodium chloride
• Gasoline
• Dilute sodium hydroxide
• Dilute hydrochloric acid
• Mineral oil
• Barium hydroxide
Any many others
Note: Cannot be used for explosion-proof applications
Built-in Chip Immunity
Chip immunity performance has been provided to greatly reduce false signals caused by spatter accumulation and other causes, almost eliminating the needs for cleaning, e.g., with metal brushes.
Flush Mounting
Main Performance Comparison to Previous OMRON Products
The chemical resistance has been certified by Ecolab Europe
Lineup
Sensors
DC 2-Wire, Pre-wired Models
Size | Sensing distance | Output | Operation mode | Model | |
---|---|---|---|---|---|
Shielded | M8 | 1.5 mm | DC 2-Wire (polarity) | NO | E2FM-X1R5D1 2M * |
M12 | 2 mm | E2FM-X2D1 2M * | |||
M18 | 5 mm | E2FM-X5D1 2M * | |||
M30 | 10 mm | E2FM-X10D1 2M * |
* Fluororesin-coated models are also available. The model numbers are E2FM-QX[]D1. The cable material, however, is vinyl chloride and requires separate protection.
DC 2-wire Pre-wired Smartclick Connector Models (M12)
Size | Sensing distance | Output | Operation mode | Model | |
---|---|---|---|---|---|
Shielded | M8 | 1.5 mm | Polarity Pin allocations: 1-4 | NO | E2FM-X1R5D1-M1TGJ 0.3M |
M12 | 2 mm | Polarity Pin allocations: 1-4 | E2FM-X2D1-M1TGJ 0.3M | ||
No polarity Pin allocations: 3-4 | E2FM-X2D1-M1TGJ-T 0.3M | ||||
M18 | 5 mm | Polarity Pin allocations: 1-4 | E2FM-X5D1-M1TGJ 0.3M | ||
No polarity Pin allocations: 3-4 | E2FM-X5D1-M1TGJ-T 0.3M | ||||
M30 | 10 mm | Polarity Pin allocations: 1-4 | E2FM-X10D1-M1TGJ 0.3M | ||
No polarity Pin allocations: 3-4 | E2FM-X10D1-M1TGJ-T 0.3M |
DC 3-Wire, Pre-wired Models
Size | Sensing distance | Model | ||
---|---|---|---|---|
Output configuration: NPN NO | Output configuration: PNP NO | |||
Shielded | M8 | 1.5 mm | E2FM-X1R5C1 2M | E2FM-X1R5B1 2M |
M12 | 2 mm | E2FM-X2C1 2M | E2FM-X2B1 2M | |
M18 | 5 mm | E2FM-X5C1 2M | E2FM-X5B1 2M | |
M30 | 10 mm | E2FM-X10C1 2M | E2FM-X10B1 2M |
Note: Models with NC operation are also available. Ask your OMRON representative for details.
DC 3-Wire, M12 Connector Models
Size | Sensing distance | Model | ||
---|---|---|---|---|
Output configuration: NPN NO | Output configuration: PNP NO | |||
Shielded | M8 | 1.5 mm | E2FM-X1R5C1-M1 | E2FM-X1R5B1-M1 * |
M12 | 2 mm | E2FM-X2C1-M1 | E2FM-X2B1-M1 * | |
M18 | 5 mm | E2FM-X5C1-M1 | E2FM-X5B1-M1 * | |
M30 | 10 mm | E2FM-X10C1-M1 | E2FM-X10B1-M1 * |
Accessories (Order Separately)
Sensor I/O Connectors (M12, Sockets on One Cable End)
(Models for Connectors and with Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.)
Appearance | Cable length |
Sensor I/O Connector model number |
Applicable Proximity Sensor model number |
---|---|---|---|
Straight | 2 m | XS2F-D421-DC0-F | E2FM-X[]C1-M1 E2FM-X[]B1-M1 |
5 m | XS2F-D421-GC0-F | ||
L-shape | 2 m | XS2F-D422-DC0-F | |
5 m | XS2F-D422-GC0-F | ||
Smartclick Connector Relay Models (M12) | 2 m | XS5F-D421-D80-F | E2FM-X[]D1-M1TGJ E2FM-X[]D1-M1TGJ-T |
5 m | XS5F-D421-G80-F |
Specifications
DC 2-Wire (E2FM-X[]D[])
Size | M8 | M12 | M18 | M30 | M12 | M18 | M30 | |
---|---|---|---|---|---|---|---|---|
Shielded | Shielded | |||||||
Model | E2FM- X1R5D1-[] |
E2FM- X2D1-[] |
E2FM- X5D1-[] |
E2FM- X10D1[] |
E2FM- X2D1- M1T1GJ-T |
E2FM- X5D1- M1T1GJ-T |
E2FM- X10D1- M1T1GJ-T |
|
Sensing distance | 1.5 mm±10% | 2 mm ±10% |
5 mm ±10% |
10 mm ±10% |
2 mm±10% | 5 mm±10% | 10 mm±10% | |
Set distance | 0 to 1.05 mm | 0 to 1.4 mm |
0 to 3.5 mm |
0 to 7 mm |
0 to 1.4 mm | 0 to 3.5 mm | 0 to 7 mm | |
Differential travel | 15% max. of sensing distance | |||||||
Sensing object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Catalog.) |
|||||||
Standard sensing object | Iron, 8 × 8 × 1 mm |
Iron, 12 × 12 × 1 mm |
Iron, 30 × 30 × 1 mm |
Iron, 54 × 54 × 1 mm |
Iron, 12 × 12 × 1 mm |
Iron, 30 × 30 × 1 mm |
Iron, 54 × 54 × 1 mm |
|
Response frequency *1 |
200 Hz | 100 Hz | 100 Hz | 50 Hz | 100 Hz | 100 Hz | 50 Hz | |
Power supply voltage (operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | |||||||
Leakage current | 0.8 mA max. | |||||||
Output configuration | With polarity | No polarity | ||||||
Control output |
Switching capacity |
3 to 100 mA | ||||||
Residual voltage |
3 V max. (Load current: 100 mA max., Cable length: 2 m) |
5 V max. (Load current: 100 mA max., Cable length: 2 m) |
||||||
Indicators | Operation indicator (red LED), Setting/Operation indicator (green LED) | |||||||
Operation mode (with sensing object approaching) |
NO *2 | |||||||
Protection circuits | Surge suppressor, Load short-circuit protection | |||||||
Ambient temperature range |
Operating/Storage: -25 to 70°C (with no icing or condensation) | |||||||
Ambient humidity range |
Operating/Storage: 35% to 95% (with no condensation) | |||||||
Temperature influence | ±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C. | |||||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||||
Degree of protection | IEC 60529 IP67 | |||||||
Connection method | Unmarked: Pre-wired Models (Standard cable length: 2 m) Models ending with -M1GJ-[]: Pre-wired Connector Models (Standard cable length: 300 mm) |
|||||||
Weight (packed state) |
Pre-wired Models (2 m) |
Approx. 105 g | Approx. 190 g |
Approx. 215 g |
Approx. 295 g |
— | — | — |
Pre-wired Connector Models |
Approx. 65 g | Approx. 85 g |
Approx. 110 g |
Approx. 190 g |
Approx. 85 g | Approx. 110 g | Approx. 190 g | |
Mate- rials |
Case | Stainless steel (SUS303) | ||||||
Sensing surface (thickness) |
Stainless steel (SUS303) | |||||||
(0.4 mm) | (0.8 mm) | (0.8 mm) | ||||||
Clamping nuts |
Stainless steel (SUS303) | |||||||
Cable | PVC (flame retardant) | |||||||
Toothed washer |
Zinc-plated iron | |||||||
Accessories | Instruction manual |
*2. NC (normally closed) models are also available. Contact your OMRON representative.
DC 3-Wire (E2FM-X[]C[], E2FM-X[]B[])
Size | M8 | M12 | M18 | M30 | |
---|---|---|---|---|---|
Shielded | Shielded | ||||
Model | E2FM-X1R5[] | E2FM-X2[] | E2FM-X5[] | E2FM-X10[] | |
Sensing distance | 1.5 mm±10% | 2 mm±10% | 5 mm±10% | 10 mm±10% | |
Set distance | 0 to 1.05 mm | 0 to 1.4 mm | 0 to 3.5 mm | 0 to 7 mm | |
Differential travel | 15% max. of sensing distance | ||||
Sensing object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Catalog.) | ||||
Standard sensing object |
Iron, 8 × 8 × 1 mm | Iron, 12 × 12 × 1 mm | Iron, 30 × 30 × 1 mm | Iron, 54 × 54 × 1 mm | |
Response frequency *1 | 200 Hz | 100 Hz | 100 Hz | 50 Hz | |
Power supply voltage (operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | ||||
Current consumption | 10 mA max. | ||||
Output configuration | PNP open collector output | ||||
Control output |
Switching capacity |
200 mA max. | |||
Residual voltage |
2 V max. (Load current: 200 mA, Cable length: 2 m) | ||||
Indicators | Operation indicator (yellow LED) | ||||
Operation mode (with sensing object approaching) |
C1 Models: NPN open collector, NO (normally open) *2 B1 Models: PNP open collector, NO (normally open) *2 |
||||
Protection circuits | Reversed power supply polarity protection, Surge suppressor, Load short-circuit protection, and Reversed output polarity protection (except the E2FM-X1R5B1-M1) |
||||
Ambient temperature range |
Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C. | ||||
Voltage influence | ±1% max. of sensing distance in the rated voltage ±15% range (using the sensing distance at the rated voltage as standard) |
||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | IEC 60529 IP67 | ||||
Connection method | Unmarked: Pre-wired Models (Standard cable length: 2 m) Models ending with -M1: Connector Models |
||||
Weight (packed state) |
Pre-wired Models (2 m) |
— | Approx. 170 g | Approx. 190 g | Approx. 275 g |
Pre-wired Connector Models |
Approx. 45 g | Approx. 55 g | Approx. 75 g | Approx. 160 g | |
Materials | Case | Stainless steel (SUS303) | |||
Sensing surface |
Stainless steel (SUS303) | ||||
(thickness) | (0.4 mm) | (0.8 mm) | |||
Clamping nuts |
Stainless steel (SUS303) | ||||
Toothed washer |
Zinc-plated iron | ||||
Accessories | Instruction manual |
*2. NC (normally closed) models are also available. Contact your OMRON representative.
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details