1. Confirming a pneumatic slide has retracted
A pneumatic slide can position the sensor in a compatible T-slot so its piston magnet crosses the switching point near the retracted position. The normally open reed contact changes state when the magnet enters the response region. A compatible controller reads the AC/DC three-wire signal before beginning the next machine movement.
Problem Solved
A local retracted-position signal helps the controller coordinate the next movement after the slide returns, without requiring an optical target or exposed mechanical limit-switch actuator.
Cylinder retraction
Reed NO
T-slot
2. Monitoring an intermediate cylinder position
A cylinder that must pass a monitored intermediate position can place the sensor along a compatible slot at that location. The passing piston magnet produces a switching interval rather than a continuous distance measurement. The typical 10 mm overrun distance and 400 Hz switching specification guide qualification against cylinder speed and controller sampling.
Problem Solved
A discrete magnet-passage event gives the controller an intermediate travel reference, helping coordinate a process step without treating the sensor as a continuous stroke-measurement device.
Intermediate travel
400 Hz
Magnet passage
3. Verifying a cylinder-driven clamp position
A cylinder-driven clamp can mount the sensor at the piston position associated with its commanded clamp state. The reed output supplies the local magnet indication to compatible control wiring, while the LED assists position setup. Where flexible cable routing is needed, the PUR drag-chain cable must remain within its documented bending limits.
Problem Solved
A piston-position indication supports clamp sequencing and detects failure to reach the monitored position, while actual clamping force remains a separate condition for the machine to establish.
Clamp sequencing
LED indication
PUR cable