Technical Overview
The Omron E3S-CD11 2M is a horizontal E3S-C photoelectric sensor with diffuse-reflective and a 700 mm rated sensing range. It uses a infrared led, 850 nm and a 2 m pre-wired cable. The metal housing is rated IP67 and designed for oil-resistant environments.
Omron E3S-CD11 2M: diffuse-reflective, 700 mm range, 10–30 V DC, IP67 metal housing.
Key Features
- Exact Omron model: E3S-CD11 2M
- Horizontal diffuse-reflective sensing
- Rated sensing range: 700 mm
- Infrared LED, 850 nm light source
- Switch-selectable NPN/PNP open-collector output
- 10–30 V DC supply
- 40 mA max. output/load specification
- IP67; oil-resistant; indoor NEMA 6P
- Zinc die-cast metal housing
- 2 m pre-wired cable
Horizontal diffuse-reflective sensing | Rated sensing range: 700 mm
Technical Specification Matrix
| Parameter | Value |
| Manufacturer | Omron |
| Product type | Oil-resistant, long-range photoelectric sensor with metal case |
| Orientation | Horizontal |
| Sensing method | Diffuse-reflective |
| Sensing distance | 700 mm |
| Standard target | White paper, 300 × 300 mm |
| Light source | Infrared LED, 850 nm |
| Power supply | 10–30 V DC (10% p-p ripple included) |
| Current consumption | 40 mA max. |
| Control output | NPN/PNP open collector, switch-selectable; 30 V DC max., 100 mA max. |
| Operation mode | Light-ON / Dark-ON, switch-selectable |
| Response time | 2 ms max. operate/reset |
| Protection | IEC IP67; oil-resistant; NEMA 6P indoor use |
| Connection | Pre-wired cable, 2 m |
| Housing | Zinc die-cast |
| Operating temperature | −25 to 55°C |
| Operating humidity | 35–85% RH |
| Physical Weight (kg) | 0.150 (approx. 150 g packed, cable type) |
| Dimensions L x W x H (cm) | Overall dimensions not stated in the checked manufacturer source. |
Suggested applications
Engineering suggestions require suitability checks for your installation.
1. Machine station part detection
Monitor a part or package at a machine station in an environment where oil exposure is possible.
Potential use
Select the appropriate sensing mode and verify range and alignment using the actual target and reflector where required.
oil-resistant
IP67
2. Conveyor passage monitoring
Detect product flow at a conveyor or transfer point with a metal-bodied photoelectric sensor.
Potential use
Set output polarity and Light-ON/Dark-ON logic to suit the controller input, then validate machine response.
700 mm
10–30 V DC