1. Ferrous component presence detection
The sensor detects ferrous metal at a nominal 10 mm distance.
Position the ferrous target within the 0 to 8 mm setting distance and verify detection with its actual size and orientation.
USD 37.20
Omron TL-N10MF1 2M is an unshielded 10 mm DC 3-wire PNP NO proximity sensor with a 2 m cable and IP67 protection.
The Omron TL-N10MF1 2M is an unshielded rectangular inductive proximity sensor with a 10 mm nominal sensing distance, DC 3-wire PNP normally-open output and a 2 m pre-wired cable. It operates from 10 to 30 VDC (rated 12 to 24 VDC) and detects ferrous metal targets; non-ferrous targets reduce sensing range. The sensing head measures 30 x 30.5 x 52.5 mm. Omron lists IEC IP67 protection and its internal oil-proof standard. Omron listed this exact model as selling and standard-stock on 2026-06-10, with stock indicator not reported by Omron.
An unshielded 10 mm inductive proximity sensor with DC 3-wire PNP normally-open output for ferrous targets.
Detect ferrous targets at a 10 mm nominal distance with DC 3-wire PNP NO operation and IP67 protection.
| Parameter | Value |
|---|---|
| Product type | Rectangular unshielded inductive proximity sensor |
| Sensing distance | 10 mm ±10% |
| Setting distance | 0 to 8 mm |
| Differential distance | 15% max. of sensing distance |
| Standard sensing object | Iron, 40 x 40 x 1 mm |
| Sensing target material | Ferrous metal; sensing distance decreases with non-ferrous metals |
| Response frequency | 40 Hz average |
| Power supply voltage | 12 to 24 VDC, ripple 10% p-p max. |
| Operating voltage range | 10 to 30 VDC |
| Current consumption | 8 mA max. at 12 VDC; 15 mA max. at 24 VDC |
| Control output | PNP, DC 3-wire, normally-open; 100 mA max. at 12 VDC and 200 mA max. at 24 VDC |
| Residual voltage | 1 V max. at 200 mA load current |
| Indicator | Detection indicator (red) |
| Protection circuit | Reverse polarity protection; surge suppressor |
| Protection rating | IEC IP67; Omron internal oil-proof standard |
| Connection | Pre-wired, 2 m cable |
| Sensing head dimensions | 30 x 30.5 x 52.5 mm |
| Housing material | Heat-resistant ABS resin |
| Accessories | Instruction manual, mounting bracket and Phillips mounting screw |
| Physical Weight (kg) | 0.240 (approx., packaged). |
| Dimensions L x W x H (cm) | See the Omron drawing; manufacturer lists the sensing head size as 30 x 30.5 x 52.5 mm (cable excluded). |
| Supply status | Active; Omron listed TL-N10MF1 2M as selling and standard-stock on 2026-06-10; stock indicator not reported by Omron. |
Engineering suggestions require suitability checks for your installation.
The sensor detects ferrous metal at a nominal 10 mm distance.
Position the ferrous target within the 0 to 8 mm setting distance and verify detection with its actual size and orientation.
The DC 3-wire PNP NO output can signal a machine part entering or leaving the sensing zone.
Connect to a compatible 10 to 30 VDC input and follow Omron clearance recommendations for nearby metal and adjacent sensors.