VF200 Series – AVF200-0022 – Inverter VF200 – Panasonic Compact inverters

USD $ 141.33

SKU: AVF200-0022

Specifications

project content
Order product number AVF200-0022
Model AVF200-0022
Standard motor output (kW) 0.2kW
Rated output : Rated voltage Single phase 200V~230V AC (supply voltage ratio)
Rated output : Overload current rating 150% of rated output current for 1 minute
Input power supply: phase number, voltage, frequency Single phase 200V~230V AC 50/60Hz
Input power : Voltage is allowed to vary +10%, -15% of rated input AC voltage
Input power : Frequency allowed to vary ±5% of rated input frequency
Input power : Transient voltage drop tolerance It continues to operate above 165V AC and continues to operate for 165ms when it drops below 15V AC
Output Frequency : Frequency range 0.5Hz~400Hz
Output Frequency : Frequency display Digital display
Output Frequency : Frequency accuracy Analog setting: Maximum set frequency± within 0.5% (25°C±10°C) Digital setting: maximum set frequency± within 0.01% (-10°C~+50°C)
Output Frequency : Frequency resolution Digital setting: 0.1Hz Analog setting: 0.1Hz (in 50/60Hz mode)
Inverter control mode High carrier frequency sine wave PWM control (optional V/F control, simple vector control)
Carrier frequency V/F control setting: 7 types can be selected (0.8Hz~10kHz variable) Simple vector control setting: 4 types (2.5Hz~10kHz variable) (0.8kHz, 1.1kHz, 1.6kHz, 2.5kHz, 5.0kHz, 7.5kHz, 10.0kHz)
Run : Run • Stop Operation panel switch Selectable 1A contact signal, 3-wire input (1A, 1B contact signal) RS485 communication Standby time can be set (0.1 seconds ~ 100 seconds)
Run : Forward or reverse Operation panel switch 1A contact signal (can be set to prohibit inversion) RS485 communication
Run : Jog run The operating frequency is arbitrarily set from 0.5Hz~400Hz, and the acceleration and deceleration time is set arbitrarily from 0.04 seconds ~ 3600 seconds
Run : Stop mode Deceleration stop • Inertial stop (choose to switch)
Run : Reset function Stop signal reset, external reset, panel reset (configurable) and power reset
Run : Start frequency Set arbitrarily in 0.5Hz~60Hz
Run : Stop frequency Set arbitrarily in 0.5Hz~60Hz
Run : Stop and start running again Restart 0Hz, Restart Operating Frequency, Restart Speed Search (Select Toggle)
Run : Speed Search Speed search at startup (configurable)
Run : Retry the function Retry selection: function yes/no, retry abnormal content selection Number of re-attempts: 1~10 times arbitrary setting
Control : Frequency setting signal Panel settings (operation panel): potentiometer, digital settings Analog setting signal for external operation: • Potentiometer (10kΩ, 1/4W or more) •0V-5V DC、0V-10V DC •4mA-20mA •0mA-20mA (with external resistors of 200Ω and 1/4W or more) External control operation digital setting signal: • PWM signal (signal period: 0.9ms~1100ms) • Frequency rise/decrease SW • Storage SW signal Communication setting: RS485 communication
Control : Voltage/frequency characteristics Substrate frequency: fixed at 50Hz and 60Hz, set arbitrarily at 45Hz~400Hz 3-point V/F mode: set the voltage and frequency arbitrarily V/F curve: constant torque • reduced torque mode (select toggle)
Control : Torque boost 0~40% arbitrary setting, automatic torque increase (optional)
Control : Acceleration and deceleration time 0.04 sec. ~ 3600 sec. (individual settings for acceleration and deceleration)
Control : Acceleration and deceleration characteristics Straight, S-type acceleration and deceleration (optional)
Control : 2nd function selection Select the second function (acceleration and deceleration time, torque boost, voltage/frequency characteristics.) (Substrate frequency, 2-point V/F mode), electronic thermal sensitivity, analog frequency setting)
Control : Multi-speed frequency setting • Multi-speed operation: up to 16 speed (arbitrary frequency) • Timer operation: up to 8 speed (arbitrary frequency) • Pulse input operation: up to 8 speed settings (arbitrary frequency) It can be linked to acceleration and deceleration times
Control : Frequency jump setting Up to 3 settings (the frequency jump range is set arbitrarily between 1Hz~10Hz)
Control : Upper limit frequency setting 0.5Hz~400Hz arbitrary setting
Control : Lower limit frequency setting 0.5Hz~400Hz arbitrary setting
Control: Bias • gain frequency setting Bias frequency: -99%~250% arbitrary setting Gain frequency: 0~500% arbitrary setting
Control : External stop function External abnormal stop, inertial stop (optional)
Control : PID function PID control mode (configurable)
Control : Auto-tune Automatic tuning of motor constants
Control : Slip rate compensation control Configurable
Control : Cooling fan ON/OFF control Configurable
Control : Communication functions • Interface: RS485 serial communication • Communication speed: 4800/9600/19200/38400 bps (optional) Protocol: MEWTOCOL-COM/Modbus (RTU) (optional) • Communication mode: half-duplex mode • Maximum number of connections: 31 • Maximum transmission distance: 500m (total wiring length)
Braking : Regenerative braking torque •200V 0.2kW: 100% or more, 0.4kW: 80% or more, 0.75kW~2.2kW: 20% or more • 400V 0.75kW~15kW: 20% or more
Braking : DC braking Actions below the stop frequency • Braking torque level: 0~100 (set 20 segments) • Braking time: 0.1 seconds ~ 120 seconds arbitrary setting
Output signal : Analog output Output specification: 0V~10V DC (max. 1mA) Output function: Output frequency and output current ratio (optional)
Output signal: Open collector output Output specifications: maximum rated 50V DC, 50mA Output functions: operating signal, arrival signal, overload alarm, frequency detection, reversal signal abnormal alarm, Current Sensing, Timer End Signal, Output Frequency/Current Ratio PWM Signal (1ms Period) (Selectable)
Output signal : Relay output Output specification: 1c contact (contact capacity 230V AC, 0.3A resistance load) Output functions: running signal, arrival signal, overload alarm, frequency detection, inversion Signal abnormality alarm, current detection, timer end signal (optional)
Display : Running•Control Status Output frequency, line speed display (optional), direction of rotation Output voltage, internal DC voltage, set frequency, communication station number, timer run times, alarm type, Control terminal status (input signal, output signal), operating status, PID (set value, measured value, output value), Autotune progression status Cumulative operating time, cumulative fan operating time
Display : Abnormal content Display symbol when the protection function is active (abnormal content can be stored 4 times)
Protection : Current limit The current limit function can be set at 1%~200% of the rated output current
Protection : Trip (stop) Transient overcurrent (SC1-6), temperature abnormality (OH) Overcurrent (OC1-3), Overload & Electronic Thermal Relay (OL), Undervoltage (LU), Overvoltage (OU1-3), Cooling fan failure (FAN), external exception (AU), operation exception (OP), CPU error (CPU)
Protection : Stall prevention function Prevent overcurrent stall and prevent overvoltage stall
Environment : Use ambient temperature and humidity -10°C~+50°C (Note 1) (no freezing), 90%RH or less (no condensation) (Note 1): -10°C~+40°C for lateral tight installation.
Environment : Storage temperature and humidity -25°C~+65°C, 95%RH or less
Environment : Vibration 5.9m/s2 (0.6G) or less
Environment : Elevation The elevation is below 1000m
Environment : Place of use Indoors, should be free of corrosive gases, flammable gases, oil mist, dust
Protection Construct IP20 in-disk mounting form
Cooling method •200V 0.2kW~0.75kW: self-cooling, 1.5kW~2.2kW: air-cooled • 400V 0.75kW: self-cooling•1.5kW~15kW: air-cooled