UM30-21311B Ultrasonic sensors – SICK Sensor

AUD $ 527.68

SKU: SICK 6068449

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6068449
Distance Sensor Model: UM30-21311B
OEM Spec Ref

Mechanics/electronics

Supply voltage Vs DC 9 V … 30 V 1)
Power consumption ≤ 2.4 W 2)
Initialization time < 300 ms
Design Cylindrical
Housing material Metal (nickel-plated brass, PBT)

Ultrasonic transducer: polyurethane foam, glass epoxy resin

Thread size M30 x 1.5
Connection type Male connector, M12, 5-pin
Indication LED display, 2 x LED
Weight 150 g
Sending axis Straight
Dimensions (W x H x D) 30 mm x 30 mm x 84 mm
Enclosure rating IP65 / IP67
Protection class III
  • 1) Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2.
  • 2) Without load.

Performance

Operating range, limiting range 200 mm … 1,300 mm, 2,000 mm
Target Natural objects
Resolution ≥ 0.18 mm
Repeatability ± 0.15 % 1)
Accuracy ± 1 % 2) 3)
Temperature compensation
Response time 92 ms
Switching frequency 8 Hz
Output time 23 ms
Ultrasonic frequency (typical) 200 kHz
Detection area (typical) See diagrams
Additional function Adjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in of digital output, set levels of digital outputs, invertable digital output, set on delay digital output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, Display (can be deactivated), teach-in button(s) (can be deactivated), reset to factory default
  • 1) In relation to the current measured value, minimum value ≥ resolution.
  • 2) Referring to current measurement value.
  • 3) Temperature compensation can be switched off, without temperature compensation: 0.17 % / K.

Interfaces

IO-Link ✔ , IO-Link V1.1
Function Process data, diagnosis, parameterization, data storage
Digital output
Number 1)
Type Push-pull: PNP/NPN
Maximum output current IA ≤ 100 mA
Multifunctional input (MF) 1 x MF
Hysteresis 20 mm
  • 1) Push-pull: PNP/NPN HIGH = UV – (< 3 V) / LOW < 3 V.

Ambient data

Ambient temperature, operation –25 °C … +70 °C
Ambient temperature, storage –40 °C … +85 °C