Specifications

Main
Part Number LC1DT25BDC LC1DT25M7C
Product Series TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca
product type Contactor Contactor
product short name LC1D LC1D
Application field of contactor Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
use category AC-1AC
-3
AC-1AC
-3
number of poles 4P 4P
Rated working voltage [Ue] Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Rated operating current [Ie] 25 A 60 °C) at <= 440 V AC AC-1 for power circuits
12 A 60 °C) at <= 440 V AC AC-3 for power circuits
25 A 60 °C) at <= 440 V AC AC-1 for power circuits
12 A 60 °C) at <= 440 V AC AC-3 for power circuits
[Uc] control circuit voltage 24 V DC 230V AC 50/60Hz
Additional information
model LC1D LC1D
Loop contact type 4 NO 4 NO
protection cap None None
Conventional thermal current [Ith] 25 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
25 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
Rated short-time withstand current [Icw] 105 A at <40 °C – 10 s for power circuit
210 A at <40 °C – 1 s for power circuit
30 A at <40 °C – 10 min for power circuit
61 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
105 A at <40 °C – 10 s for power circuit
210 A at <40 °C – 1 s for power circuit
30 A at <40 °C – 10 min for power circuit
61 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
Fuses for use with relays 10 A gG for signal circuits according to IEC 60947-5-1
40 A gG at <= 690 V for power circuits type 1
25 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
40 A gG at <= 690 V for power circuits type 1
25 A gG for power circuits for type 2 at <= 690 V
average impedance 2.5 mΩ – Ith 25 A 50 Hz for power loop 2.5 mΩ – Ith 25 A 50 Hz for power loop
Rated insulation voltage [Ui] Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Overvoltage category III III
pollution level 3 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 30 Mcycles 15 Mcycles
Electrical life 0.8 Mcycles <= 440 V at 25 A AC-1 Ue 0.8 Mcycles <= 440 V at 25 A AC-1 Ue
Control loop characteristics DC standard AC at 50/60 Hz
Surge Suppression Module Built-in bidirectional peak current limiting diode No built-in surge suppression module
Control voltage limit 0.1…0.25 Uc -40…60 °C release
0.7…1.25 Uc -40…60 °C run
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
Surge power (W) 5.4W (20°C)
Holding power consumption(W) 5.4 W at 20 °C
Rated operating power (W) 5.4W
action time 55 ms to close,
20 ms to break
12…22 ms close
4…19 ms break
time constant 28ms
operating frequency 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C
Wiring capacity Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit:
screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals
Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power
circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power
circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power
circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals
Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals
Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals
Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals
Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals
control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal
control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal
Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit:
screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals
Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power
circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power
circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power
circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals
Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals
Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals
Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals
Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals
control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal
control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal
Tightening torque Power circuit: 1.7 Nm via screwdriver Ø 6 flat
power circuit: 1.7 Nm via screwdriver No 2 Phillips screw
control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw
Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5 Power circuit
: 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5
Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening
Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening
Power circuit: 1.7 Nm via screwdriver Ø 6 flat
power circuit: 1.7 Nm via screwdriver No 2 Phillips screw
control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw
Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5 Power circuit
: 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5
Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening
Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1
1 NO + 1 NC
Signal loop frequency 25…400Hz 25…400Hz
Minimum switching current [Imin] 5 mA for signal loop 5 mA for signal loop
Insulation resistance > 10 MΩ for signal loops > 10 MΩ for signal loops
non-overlapping time 1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
installation method Chassis mounting
rail installation
DIN rail installation
base plate installation
environment
standard IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
certified product CCC
CE
UKCA
CCC
CE
UKCA
IP protection class IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
high 85 mm 85 mm
width 45 mm 45 mm
depth 99 mm 92 mm
Product Weight 0.365 kg 0.365kg
packaging unit
Unit Type of Package 1 PCE PCE
Number of Units in Package 1 1 1
Package 1 Height 8.8cm 8.8cm
Package 1 Width 10.6 cm 9.9 cm
Package 1 Length 5.2 cm 5.2 cm
Package 1 Weight 382.3g 381.48g
Unit Type of Package 2 CAR CAR
Number of Units in Package 2 20 21
Package 2 Height 30.0cm 30.0cm
Package 2 Width 40.0cm 40.0cm
Package 2 Length 15.0cm 15.0cm
Package 2 Weight 7.696 kg 8.061kg
Unit Type of Package 3 PAL PAL
Number of Units in Package 3 320 336
Package 3 Height 60.0cm 60.0cm
Package 3 Width 80.0cm 80.0cm
Package 3 Length 75.0cm 75.0cm
Package 3 Weight 122.536kg 128.376 kg
contract warranty
Warranty 18 months 18 months

 

Weight N/A
Dimensions N/A