TeSys Deca – LC1D – 4 Poles (4NO) Contactor, 115A – Schneider Contactors & Reversing Contactors

USD $ 383.46

SKU: LC1D115004M7

Specifications

Main
Part Number LC1D115004M7
Product Series TeSys
Product Series TeSys Deca
product type Contactor
product short name LC1D
Application field of contactor Applied to non-inductive or micro-inductive load, resistance furnace
use category AC-1
number of poles 4P
Rated working voltage [Ue] Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Rated operating current [Ie] 200 A 60 °C) at <= 440 V AC AC-1 for power circuits
[Uc] control circuit voltage 230V AC 50/60Hz
Additional information
model LC1D
Loop contact type 4 NO
Contactor Compatibility Features M14
protection cap Bring
Conventional thermal current [Ith] 200 A at <60 °C for power circuits
Rated making capacity [Irms] 1260 A at 440 V for power circuits conforming to IEC 60947
Rated breaking capacity 1100 A at 440 V for power circuits conforming to IEC 60947
Rated short-time withstand current [Icw] 250 A at <40 °C – 10 min for power circuit
550 A at <40 °C – 1 min for power circuit
950 A at <40 °C – 10 s for power circuit
1100 A at <40 °C – 1 s for power circuits
Fuses for use with relays 250 A gG at <= 690 V with type 1 suitable power circuit
200 A gG at <= 690 V with type 2 suitable power circuit
average impedance 0.6 mΩ – Ith 200 A 50 Hz for power circuits
power consumption per pole 24W AC-1
Rated insulation voltage [Ui] Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III
pollution level 3
Rated impulse withstand voltage [Uimp] 8 kV according to IEC 60947
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 8 Mcycles
Electrical life 0.8 Mcycles <= 440 V at 200 A AC-1 Ue
Control loop characteristics AC at 50/60 Hz
Surge Suppression Module Built-in bidirectional peak current limiting diode
Control voltage limit 0.3…0.5 Uc -40…70 °C Release AC 50/60 Hz
0.8…1.15 Uc -40…55 °C Run AC 50/60 Hz
1…1.15 Uc 55…70 °C Run AC 50 /60Hz
(~50Hz pickup) power consumption (VA) 280…350 VA 60 Hz 0.8 20 °C)
280…350 VA 50 Hz 0.8 20 °C)
(~50Hz hold) power consumption (VA) 2…18 VA 60 Hz 0.3 20 °C)
2…18 VA 50 Hz 0.3 20 °C)
heat dissipation 3…8 W at 50/60 Hz
action time 6…20 ms open
20…50 ms close
operating frequency 2400 cycles/h at <60 °C
Wiring capacity Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening1 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening1 1 …2.5 mm² Cable option: flexible without wire terminals
Control circuit: screw tight2 1…2.5 mm² Cable option: flexible without cable terminals
Control circuit: screw tight1 1…2.5 mm² Cable option : Solid without wire terminals
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Hard wire without wire terminals
Power circuit: Terminal 1 10…120 mm² Cable selection: Flexible wire without wire Terminals
Power circuit: Terminal 2 10…50 mm² Cable option: Flexible cord without wire terminal
Power circuit: Terminal 1 10…120 mm² Cable option: Flexible cord with cable terminal
Power circuit: Terminal 2 10… 50 mm² Cable option: Flexible with wire terminals Power
circuit: Terminal 1 10…120 mm² Cable option: Solid without wire terminals
Power circuit: Terminal 2 10…50 mm² Cable option: Solid No With wire terminal
Tightening torque Control circuit: 1.2 Nm via screwdriver Ø 6 flat
Control circuit: 1.2 Nm via screwdriver No. 2 Phillips screw
power supply circuit: 12 Nm via terminal hex 4 mm
control circuit: 1.2 Nm via screwdriver With a screwdriver pozidriv No 2
installation method DIN rail installation
base plate installation
environment
standard CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
certified product CCC
RINA
GOST
UL
CSA
LROS (Lloyds register of shipping)
BV
GL
DNV
UKCA
IP protection class IP20 front panel complies with screwed
Protective measures TH conforms to IEC 60068-2-30
climate tolerance Complies with IACS E10 for exposure to hot flashes
Complies with IEC 60947-1 Annex Q category D for exposure to hot flashes
ambient air temperature -40…60 °C
60…70 °C with derating
working altitude 0…3000 m
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-1
flame retardant V1 complies with UL 94
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz))
shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance
with contacts closed (15 gn (11ms))
Shock performance Contact opening (6 gn (11ms))
high 158 mm
width 150 mm
depth 132 mm
Product Weight 2.86kg
packaging unit
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 19.500 cm
Package 1 Width 21.000 cm
Package 1 Length 21.000 cm
Package 1 Weight 2.971kg
Unit Type of Package 2 P06
Number of Units in Package 2 18
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 66.478 kg
contract warranty
Warranty 18 months

 

Weight 2.86 kg
Dimensions 13.2 × 15 × 15.8 cm