$ 65.78 – $ 171.35
Main | ||||
Part Number | LC1D80B7C | LC1D80BD | LC1D80CC5C | LC1D80E7C |
Product Series | TeSys Deca | TeSys | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-3 AC-3e AC-4 AC-1 |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 300 V DC 25…400 Hz Power circuit: 660 V AC |
Power circuit: <= 300 V DC 25…400 Hz power circuit: <= 690 V AC |
Power circuit: <= 300 V DC 25…400 Hz Power circuit: 660 V AC |
Power circuit: <= 300 V DC 25…400 Hz Power circuit: 660 V AC |
Rated operating current [Ie] | 80 A 60 °C) at <= 440 V AC AC-3 for power circuit 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 80 A 60 °C) at< = 440 V AC AC-3e for power circuit |
125 A 60 °C) at <= 440 V AC AC-1 for power circuit 80 A 60 °C) at <= 440 V AC AC-3 for power circuit 80 A 60 °C) at< = 440 V AC-3e for power circuits |
80 A 60 °C) at <= 440 V AC AC-3 for power circuit 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 80 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-3 for power circuit 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 80 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 24 V AC 50/60 Hz | 24 V DC | 48 V AC 50/60 Hz | 48 V AC 50/60 Hz |
Additional information | ||||
Motor power (kW) | 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 22 kW at 220/240 V AC 50/60 Hz (AC -3) 37 kW at 380/400 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC-3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 22 kW at 220/240 V AC 50/60 Hz (AC-3e) 37 kW at 380/400 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) |
22 kW at 220…230 V AC 50 Hz (AC-3) 37 kW at 380…400 V AC 50 Hz (AC-3) 45 kW at 415…440 V AC 50 Hz (AC-3) 55 kW at 500 V AC 50 Hz (AC-3) 45 kW at 660…690 V AC 50 Hz (AC-3) 15 kW at 400 V AC 50 Hz (AC-4) 22 kW at 220…230 V AC 50 Hz (AC-3e) 37 kW at 380…400 V AC 50 Hz (AC-3e) 45 kW at 415 …440 V AC 50 Hz (AC-3e) 55 kW at 500 V AC 50 Hz (AC-3e) 45 kW at 660…690 V AC 50 Hz (AC-3e) |
55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 22 kW at 220/240 V AC 50/60 Hz (AC -3) 37 kW at 380/400 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC-3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 22 kW at 220/240 V AC 50/60 Hz (AC-3e) 37 kW at 380/400 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) |
55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 22 kW at 220/240 V AC 50/60 Hz (AC -3) 37 kW at 380/400 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC-3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 22 kW at 220/240 V AC 50/60 Hz (AC-3e) 37 kW at 380/400 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) |
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
protection cap | None | Bring | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
Rated short-time withstand current [Icw] | 640 A at <40 °C – 10 s for power circuit 990 A at <40 °C – 1 s for power circuit 135 A at <40 °C – 10 min for power circuit 320 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
640 A at <40 °C – 10 s for power circuit 990 A at <40 °C – 1 s for power circuit 135 A at <40 °C – 10 min for power circuit 320 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
640 A at <40 °C – 10 s for power circuit 990 A at <40 °C – 1 s for power circuit 135 A at <40 °C – 10 min for power circuit 320 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
640 A at <40 °C – 10 s for power circuit 990 A at <40 °C – 1 s for power circuit 135 A at <40 °C – 10 min for power circuit 320 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
average impedance | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signaling circuit: 690 V conforming to IEC 60947-1 Signaling circuit: 600 V CSA certified Signaling circuit: 600 V UL certified |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 8 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 4 Mcycles | 4 Mcycles | 4 Mcycles | 4 Mcycles |
Electrical life | 0.8 Mcycles 125 A AC-1 Ue <= 440 V 1.5 Mcycles 80 A AC-3 Ue <= 440 V 1.5 Mcycles 80 A AC-3e Ue <= 440 V 2.5 Mcycles 48 A AC-3e Ue Conditions 660/690 V |
0.8 Mcycles 125 A AC-1 Ue <= 440 V 1.5 Mcycles 80 A AC-3 Ue <= 440 V 1.5 Mcycles 80 A AC-3e Ue <= 440 V |
0.8 Mcycles 125 A AC-1 Ue <= 440 V 1.5 Mcycles 80 A AC-3 Ue <= 440 V 2.5 Mcycles 48 A AC-3 Ue 660/690 V 1.5 Mcycles 80 A AC-3e Ue <= 440 V at 2.5 Mcycles 48 A AC-3e at 660/690 V at Ue |
0.8 Mcycles 125 A AC-1 Ue <= 440 V 1.5 Mcycles 80 A AC-3 Ue <= 440 V 2.5 Mcycles 48 A AC-3 Ue 660/690 V 1.5 Mcycles 80 A AC-3e Ue <= 440 V at 2.5 Mcycles 48 A AC-3e at 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz | DC standard | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz |
0.1…0.3 Uc -40…70 °C release DC 0.85…1.1 Uc -40…55 °C run DC 1…1.1 Uc 55…70 °C run DC |
0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz |
0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
|
(~50Hz hold) power consumption (VA) | 26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) |
26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) |
26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) |
|
heat dissipation | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz | |
action time | 20…35 ms close 6…20 ms break |
95…130 ms closed 20…35 ms open |
20…35 ms close 6…20 ms break |
20…35 ms close 6…20 ms break |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire with wire terminal Control circuit: Bolt fastening1 1…2.5 mm² Cable selection: Flexible wire with wire terminal Control circuit: Bolt fastening1 1 …4 mm² Cable option: flexible without cable terminals Control circuit: screw-fastened2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-fastened1 1…4 mm² Cable option : Solid without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable option: Solid without cable terminals Power circuit: Terminal 1 4…50 mm² Cable option: Flexible without cable Terminals Power circuit: terminal 2 4…25 mm² Cable option: flexible without wire terminal Power circuit: terminal 1 4…50 mm² Cable option: flexible with wire terminal Power circuit: terminal 2 4… 16 mm² Cable option: Flexible with wire terminals Power circuit: Terminal 1 4…50 mm² Cable option: Solid without wire terminals Power circuit: Terminal 2 4…25 mm² Cable option: Solid No With wire terminal |
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Tightening torque | Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw power circuit: 12 Nm via terminals with screwdriver Ø 6 – Ø 8 flat power circuit: 12 Nm Via terminal hexagon 4 mm Control circuit: 1.2 Nm Via screw fastening with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | DIN rail installation base plate installation |
Chassis mounting rail installation |
Chassis mounting rail installation |
Chassis mounting rail installation |
environment | ||||
standard | IEC 60947-4-1 GB 14048.4 |
CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 GB 14048.4 |
certified product | CCC CE UKCA |
GOST RINA GL DNV CSA CCC UL LROS (Lloyds register of shipping) BV |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 | IP20 front panel complies with screwed | IP2x front panel for main circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C 60…70 °C with derating |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 0…3000m | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-1 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
Shock and vibration resistance | Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
Shock resistance with contacts open (2 gn (5…300 Hz)) shock resistance with contacts open (8 gn (11ms)) shock resistance with contacts closed (3 gn (5…300 Hz)) shock resistance Performance Contact closed state (10 gn (11ms)) |
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
high | 127 mm | 127 mm | 127 mm | 127 mm |
width | 85 mm | 85 mm | 85 mm | 85 mm |
depth | 130mm | 186 mm | 130mm | 130mm |
Product Weight | 1.59kg | 2.59kg | 1.59kg | 1.59kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 11.152 cm | 11.000 cm | 11.194 cm | 11.194 cm |
Package 1 Width | 15.247 cm | 16.200 cm | 15.27cm | 15.27cm |
Package 1 Length | 15.96cm | 21.700 cm | 15.906 cm | 15.906 cm |
Package 1 Weight | 1.571kg | 2.579 kg | 1.571kg | 1.571kg |
Unit Type of Package 2 | CAR | S02 | CAR | CAR |
Number of Units in Package 2 | 5 | 2 | 5 | 5 |
Package 2 Height | 19.5cm | 15.000 cm | 18.8 cm | 18.8 cm |
Package 2 Width | 29.5cm | 30.000 cm | 29.5cm | 29.5cm |
Package 2 Length | 40.7 cm | 40.000 cm | 40.4 cm | 40.4 cm |
Package 2 Weight | 8.261kg | 5.466 kg | 8.29kg | 8.29kg |
Unit Type of Package 3 | PAL | P06 | PAL | PAL |
Number of Units in Package 3 | 60 | 32 | 60 | 60 |
Package 3 Height | 75.0cm | 75.000 cm | 75.0cm | 75.0cm |
Package 3 Width | 60.0cm | 60.000 cm | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.000 cm | 80.0cm | 80.0cm |
Package 3 Weight | 103.764 kg | 97.700 kg | 104.64kg | 104.64kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||||
Part Number | LC1D80F7C | LC1D80M7C | LC1D80P7C | LC1D80Q7C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 300 V DC 25…400 Hz Power circuit: 660 V AC |
Power circuit: <= 300 V DC 25…400 Hz Power circuit: 660 V AC |
Power circuit: <= 300 V DC 25…400 Hz Power circuit: 660 V AC |
Power circuit: <= 300 V DC 25…400 Hz Power circuit: 660 V AC |
Rated operating current [Ie] | 80 A 60 °C) at <= 440 V AC AC-3 for power circuit 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 80 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-3 for power circuit 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 80 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-3 for power circuit 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 80 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-3 for power circuit 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 80 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 110V AC 50/60Hz | 230V AC 50/60Hz | 230 V AC 50/60 Hz | 380 V AC 50/60 Hz |
Additional information | ||||
Motor power (kW) | 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 22 kW at 220/240 V AC 50/60 Hz (AC -3) 37 kW at 380/400 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC-3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 22 kW at 220/240 V AC 50/60 Hz (AC-3e) 37 kW at 380/400 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) |
55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 22 kW at 220/240 V AC 50/60 Hz (AC -3) 37 kW at 380/400 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC-3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 22 kW at 220/240 V AC 50/60 Hz (AC-3e) 37 kW at 380/400 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) |
55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 22 kW at 220/240 V AC 50/60 Hz (AC -3) 37 kW at 380/400 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC-3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 22 kW at 220 /240 V AC 50/60 Hz (AC-3e) 37 kW at 380/400 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e ) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) |
55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 22 kW at 220/240 V AC 50/60 Hz (AC -3) 37 kW at 380/400 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC-3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 22 kW at 220/240 V AC 50/60 Hz (AC-3e) 37 kW at 380/400 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) |
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
protection cap | None | None | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
Rated short-time withstand current [Icw] | 640 A at <40 °C – 10 s for power circuit 990 A at <40 °C – 1 s for power circuit 135 A at <40 °C – 10 min for power circuit 320 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
640 A at <40 °C – 10 s for power circuit 990 A at <40 °C – 1 s for power circuit 135 A at <40 °C – 10 min for power circuit 320 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
640 A at <40 °C – 10 s for power circuit 990 A at <40 °C – 1 s for power circuit 135 A at <40 °C – 10 min for power circuit 320 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
640 A at <40 °C – 10 s for power circuit 990 A at <40 °C – 1 s for power circuit 135 A at <40 °C – 10 min for power circuit 320 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
average impedance | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 4 Mcycles | 4 Mcycles | 4 Mcycles | 4 Mcycles |
Electrical life | 0.8 Mcycles 125 A AC-1 Ue <= 440 V 1.5 Mcycles 80 A AC-3 Ue <= 440 V 2.5 Mcycles 48 A AC-3 Ue 660/690 V 1.5 Mcycles 80 A AC-3e Ue <= 440 V at 2.5 Mcycles 48 A AC-3e at 660/690 V at Ue |
0.8 Mcycles 125 A AC-1 Ue <= 440 V 1.5 Mcycles 80 A AC-3 Ue <= 440 V 2.5 Mcycles 48 A AC-3 Ue 660/690 V 1.5 Mcycles 80 A AC-3e Ue <= 440 V at 2.5 Mcycles 48 A AC-3e at 660/690 V at Ue |
0.8 Mcycles 125 A AC-1 Ue <= 440 V 1.5 Mcycles 80 A AC-3 Ue <= 440 V 2.5 Mcycles 48 A AC-3 Ue 660/690 V 1.5 Mcycles 80 A AC-3e Ue <= 440 V at 2.5 Mcycles 48 A AC-3e at 660/690 V at Ue |
0.8 Mcycles 125 A AC-1 Ue <= 440 V 1.5 Mcycles 80 A AC-3 Ue <= 440 V 2.5 Mcycles 48 A AC-3 Ue 660/690 V 1.5 Mcycles 80 A AC-3e Ue <= 440 V at 2.5 Mcycles 48 A AC-3e at 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz |
0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz |
0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz |
0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
(~50Hz hold) power consumption (VA) | 26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) |
26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) |
26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) |
26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) |
heat dissipation | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz |
action time | 20…35 ms close 6…20 ms break |
20…35 ms close 6…20 ms break |
20…35 ms close 6…20 ms break |
20…35 ms close 6…20 ms break |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Tightening torque | Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | Chassis mounting rail installation |
Chassis mounting rail installation |
DIN rail installation base plate installation |
DIN rail installation base plate installation |
environment | ||||
standard | IEC 60947-4-1 GB 14048.4 |
GB 14048.4 IEC 60947-4-1 |
IEC 60947-4-1 GB 14048.4 |
GB 14048.4 IEC 60947-4-1 |
certified product | CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
Shock and vibration resistance | Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
high | 127 mm | 127mm | 127mm | 127 mm |
width | 85 mm | 85 mm | 85 mm | 85 mm |
depth | 130mm | 130mm | 130 mm | 130 mm |
Product Weight | 1.59kg | 1.59kg | 1.59kg | 1.59kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 11.21 cm | 11.4 cm | 15.0cm | 11.4 cm |
Package 1 Width | 15.84cm | 14.8 cm | 11.1 cm | 14.9 cm |
Package 1 Length | 15.18cm | 15.7cm | 15.7cm | 15.6cm |
Package 1 Weight | 1.624 kg | 1.63kg | 1571.0g | 1.579kg |
Unit Type of Package 2 | CAR | CAR | CAR | CAR |
Number of Units in Package 2 | 5 | 5 | 5 | 5 |
Package 2 Height | 19.8 cm | 20.1 cm | 20.0cm | 20.0cm |
Package 2 Width | 28.7 cm | 28.8 cm | 30.0cm | 28.9 cm |
Package 2 Length | 39.9 cm | 39.9 cm | 40.0cm | 39.4 cm |
Package 2 Weight | 8.263kg | 8.351kg | 8.312 kg | 8.343 kg |
Unit Type of Package 3 | PAL | PAL | P06 | PAL |
Number of Units in Package 3 | 60 | 60 | 60 | 60 |
Package 3 Height | 75.0cm | 75.0cm | 75.0cm | 75.0cm |
Package 3 Width | 60.0cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Weight | 99.156kg | 99.156 kg | 109.738kg | 99.156 kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |