$ 55.20 – $ 200.79
Main | ||||
Part Number | LC1D65AM7 | LC1D65AB7C | LC1D65ABD | LC1D65ACC7C |
Product Series | TeSys TeSys Deca |
TeSys Deca | TeSys TeSys Deca |
TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys TeSys Deca |
TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Rated operating current [Ie] | 80 A 60 °C) at <= 440 V AC AC-1 for power circuit 65 A 60 °C) at <= 440 V AC AC-3 for power circuit 65 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-1 for power circuit 65 A 60 °C) at <= 440 V AC AC-3 for power circuit 65 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-1 for power circuit 65 A 60 °C) at <= 440 V AC AC-3 for power circuit 65 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-1 for power circuit 65 A 60 °C) at <= 440 V AC AC-3 for power circuit 65 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 230V AC 50/60Hz | 24 V AC 50/60 Hz | 24 V DC | 36 V AC 50/60 Hz |
Additional information | ||||
Motor power (kW) | 11 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 220…230 V AC 50/60 Hz (AC-3) 30 kW at 380…400 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3) 37 kW at 660…690 V AC 50/60 Hz (AC-3) 18.5 kW at 220…230 V AC 50/60 Hz (AC-3e) 30 kW at 380…400 V AC 50/60 Hz (AC-3e) 37 kW at 500 V AC 50/60 Hz (AC-3e) 37 kW at 660…690 V AC 50/60 Hz (AC-3e) |
37 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3) 30 kW at 380/400 V AC 50/60 Hz (AC-3) 37 kW at 660/690 V AC 50/60 Hz (AC-3) 37 kW at 415/440 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 30 kW at 380/400 V AC 50/60 Hz (AC-3e) 37 kW at 660/690 V AC 50/60 Hz (AC-3e) 37 kW at 415/440 V AC 50/60 Hz (AC-3e) |
11 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 220…230 V AC 50/60 Hz (AC-3) 30 kW at 380…400 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3) 37 kW at 660…690 V AC 50/60 Hz (AC-3) 18.5 kW at 220…230 V AC 50/60 Hz (AC-3e) 30 kW at 380…400 V AC 50/60 Hz (AC-3e) 37 kW at 500 V AC 50/60 Hz (AC-3e) 37 kW at 660…690 V AC 50/60 Hz (AC-3e) |
37 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3) 30 kW at 380/400 V AC 50/60 Hz (AC-3) 37 kW at 660/690 V AC 50/60 Hz (AC-3) 37 kW at 415/440 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 30 kW at 380/400 V AC 50/60 Hz (AC-3e) 37 kW at 660/690 V AC 50/60 Hz (AC-3e) 37 kW at 415/440 V AC 50/60 Hz (AC-3e) |
Motor Power | 40 hp at 460/480 V AC 50/60 Hz for 3-phase motors 5 hp at 115 V AC 50/60 Hz for 1-phase motors 10 hp at 230/240 V AC 50/60 Hz for 1 Phase motor 20 hp at 200/208 V AC 50/60 Hz for 3 phase motor 20 hp at 230/240 V AC 50/60 Hz for 3 phase motor 50 hp at 575/600 V AC 50/ 60 Hz for 3-phase motors |
40 hp at 460/480 V AC 50/60 Hz for 3-phase motors 5 hp at 115 V AC 50/60 Hz for 1-phase motors 10 hp at 230/240 V AC 50/60 Hz for 1 Phase motor 20 hp at 200/208 V AC 50/60 Hz for 3 phase motor 20 hp at 230/240 V AC 50/60 Hz for 3 phase motor 50 hp at 575/600 V AC 50/ 60 Hz for 3-phase motors |
||
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
Contactor Compatibility Features | M2 | M4 | ||
protection cap | Bring | None | Bring | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 80 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 80 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 80 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 80 A at <60 °C for power circuits |
Rated making capacity [Irms] | 140 A AC for signal circuits according to IEC 60947-5-1 250 A DC for signal circuits according to IEC 60947-5-1 1000 A at 440 V for power circuits according to IEC 60947 |
140 A AC for signal circuits according to IEC 60947-5-1 250 A DC for signal circuits according to IEC 60947-5-1 1000 A at 440 V for power circuits according to IEC 60947 |
||
Rated breaking capacity | 1000 A at 440 V for power circuits conforming to IEC 60947 | 1000 A at 440 V for power circuits conforming to IEC 60947 | ||
Rated short-time withstand current [Icw] | 520 A at <40 °C – 10 s for power circuit 900 A at <40 °C – 1 s for power circuit 110 A at <40 °C – 10 min for power circuit 260 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
520 A at <40 °C – 10 s for power circuit 900 A at <40 °C – 1 s for power circuit 110 A at <40 °C – 10 min for power circuit 260 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
520 A at <40 °C – 10 s for power circuit 900 A at <40 °C – 1 s for power circuit 110 A at <40 °C – 10 min for power circuit 260 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
520 A at <40 °C – 10 s for power circuit 900 A at <40 °C – 1 s for power circuit 110 A at <40 °C – 10 min for power circuit 260 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 125 A gG at <= 690 V for power circuits type 1 125 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 125 A gG at <= 690 V for power circuits type 1 125 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 125 A gG at <= 690 V for power circuits type 1 125 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 125 A gG at <= 690 V for type 2 for power circuits 160 A gG for at <= 690 V for type 1 for power circuits |
average impedance | 1.5 mΩ – Ith 80 A 50 Hz for power circuits | 1.5 mΩ – Ith 80 A 50 Hz for power circuits | 1.5 mΩ – Ith 80 A 50 Hz for power circuits | 1.5 mΩ – Ith 80 A 50 Hz for power circuits |
power consumption per pole | 9.6W AC-1 6.3W AC-3 6.3W AC-3e |
9.6W AC-1 6.3W AC-3 6.3W AC-3e |
||
Rated insulation voltage [Ui] | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signal circuit: 690 V conforming to IEC 60947-1 Signaling circuit: 600 V CSA certified Signaling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signal circuit: 690 V conforming to IEC 60947-1 Signaling circuit: 600 V CSA certified Signaling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 6 Mcycles | 6 Mcycles | 10 Mcycles | 6 Mcycles |
Electrical life | 1.4 Mcycles 80 A AC-1 <= 440 V at Ue 1.45 Mcycles 65 A AC-3 Ue <= 440 V 1.45 Mcycles 65 A AC-3e <= 440 V at Ue |
1.5 Mcycles 65 A AC-3 Ue <= 440 V 2.5 Mcycles 42 A AC-3 Ue 660/690 V 1.3 Mcycles 80 A AC-1 Ue <= 440 V 1.5 Mcycles 65 A AC-3e Ue <= 440 V at 2.5 Mcycles 42 A AC-3e at 660/690 V at Ue |
0.5 Mcycles 80 A AC-1 <= 440 V at Ue 1.45 Mcycles 65 A AC-3 Ue <= 440 V 1.45 Mcycles 65 A AC-3e <= 440 V at Ue |
1.5 Mcycles 65 A AC-3 Ue <= 440 V 2.5 Mcycles 42 A AC-3 Ue 660/690 V 1.3 Mcycles 80 A AC-1 Ue <= 440 V 1.5 Mcycles 65 A AC-3e Ue <= 440 V at 2.5 Mcycles 42 A AC-3e at 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz standard | AC at 50/60 Hz | DC standard | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | Built-in bidirectional peak current limiting diode | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…70 °C Release AC 50/60 Hz 0.8…1.1 Uc -40…60 °C Run AC 50 Hz 0.85…1.1 Uc -40…60 °C Run AC 60 Hz 1…1.1 Uc 60…70 °C Operation AC 50/60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.1…0.3 Uc -40…70 °C release DC 0.75…1.25 Uc -40…60 °C run DC 1…1.25 Uc 60…70 °C run DC |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
|
(~50Hz hold) power consumption (VA) | 13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
|
heat dissipation | 4…5 W at 50/60 Hz | 4…5 W at 50/60 Hz | 4…5 W at 50/60 Hz | |
action time | 4…19 ms open 12…26 ms close |
4…19 ms open 12…26 ms close |
42.5…57.5 ms closed 16…24 ms open |
4…19 ms open 12…26 ms close |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Control circuit: screw-on2 1…2.5 mm² Cable option: flexible cord with wire terminal Control circuit: screw-on1 1…4 mm² Cable option: flexible cable without cable terminal Control circuit: screw-on2 1…4 mm² cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible cable with cable terminal control circuit: screw-on1 1…4 mm² cable option : Hard wire without wire terminal Control circuit: Bolt fastening2 1…4 mm² Cable option: Hard wire without wire terminal Power circuit: EverLink BTR terminal1 1…35 mm² Cable option: Flexible wire without Wire terminal power circuit: EverLink BTR terminal 2 1…25 mm² Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 1 1…35 mm² Cable selection: flexible cord with wire terminal power circuit : EverLink BTR terminal block 2 1…25 mm² Cable option: flexible wire with wire terminal Power circuit: EverLink BTR terminal block 1 1…35 mm² Cable option: rigid without wire terminal Power circuit: EverLink BTR terminal block 2 1…25 mm² Cable option: solid without cable terminals |
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option : flexible wire with wire terminal Terminal Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit: screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal |
Control circuit: screw-on2 1…2.5 mm² Cable option: flexible cord with wire terminal Control circuit: screw-on1 1…4 mm² Cable option: flexible cable without cable terminal Control circuit: screw-on2 1…4 mm² cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible cable with cable terminal control circuit: screw-on1 1…4 mm² cable option : Solid without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Solid without wire terminals Power circuit: Screw connection1 1…35 mm² Cable selection: Flexible without wire Terminals Power circuit: Screw connection2 1…25 mm² Cable option: Flexible cord without wire terminal Power circuit: Screw connection1 1…35 mm² Cable option: Flexible cord with wire terminal Power circuit: Screw connection2 1… 25 mm² Cable option: flexible with wire terminals Power circuit: screw connection1 1…35 mm² Cable option: solid without wire terminal Power circuit: screw connection2 1…25 mm² Cable option: solid without With wire terminal |
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option : flexible wire with wire terminal Terminal Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit: screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal |
Tightening torque | Control circuit: 1.7 Nm Via EverLink BTR terminal block with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via EverLink BTR terminal block with screwdriver No 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 25…35 mm² Hex 4 mm Power circuit: 5 Nm Via EverLink BTR terminal block Cable 1…25 mm² Hexagon 4 mm Control circuit: 1.7 Nm Via EverLink BTR terminal block with screwdriver pozidriv No 2 Power circuit: 2.5 Nm Via EverLink BTR terminal block with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6 power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm Via EverLink BTR terminal block with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via EverLink BTR terminal block with screwdriver No 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 25…35 mm² Hex 4 mm Power circuit: 5 Nm Via EverLink BTR terminal block Cable 1…25 mm² Hexagon 4 mm Control circuit: 1.7 Nm Via EverLink BTR terminal block with screwdriver pozidriv No 2 Power circuit: 2.5 Nm Via EverLink BTR terminal block with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6 power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching voltage | 17 V for signal return | 17 V for signal return | ||
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | DIN rail installation base plate installation |
Chassis mounting rail installation |
Chassis mounting rail installation |
Chassis mounting rail installation |
environment | ||||
standard | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
GB 14048.4 IEC 60947-4-1 |
CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
GB 14048.4 IEC 60947-4-1 |
certified product | UL CCC GOST CSA |
CCC CE UKCA |
GOST UL CCC CSA |
CCC CE UKCA |
IP protection class | IP20 front panel complies with screwed | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP20 front panel complies with screwed | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
climate tolerance | Complies with IACS E10 for exposure to hot flashes Complies with IEC 60947-1 Annex Q category D for exposure to hot flashes |
Complies with IACS E10 for exposure to hot flashes Complies with IEC 60947-1 Annex Q category D for exposure to hot flashes |
||
ambient air temperature | -40…60 °C 60…70 °C with derating |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C 60…70 °C with derating |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 0…3000m | 3000 m None | 0…3000m | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-1 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-1 | 850 °C conforming to IEC 60695-2-11 |
flame retardant | V1 complies with UL 94 | V1 complies with UL 94 | ||
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance with contacts closed (15 gn (11ms)) Shock performance Contact opening (10 gn (11ms)) |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance with contacts closed (15 gn (11ms)) Shock performance Contact opening (10 gn (11ms)) |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
high | 122mm | 122mm | 122mm | 122mm |
width | 55 mm | 55mm | 55mm | 55mm |
depth | 120 mm | 120 mm | 120 mm | 120 mm |
Product Weight | 0.86 kg | 0.86 kg | 0.935 kg | 0.86 kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 6.300 cm | 6.145 cm | 6.2 cm | 6.222 cm |
Package 1 Width | 13.500 cm | 13.788 cm | 13.5cm | 13.477 cm |
Package 1 Length | 15.300 cm | 15.296 cm | 15.2 cm | 15.15cm |
Package 1 Weight | 923.000g | 940.0g | 984.0g | 940.0g |
Unit Type of Package 2 | S02 | S02 | S02 | S02 |
Number of Units in Package 2 | 10 | 10 | 10 | 10 |
Package 2 Height | 15.000 cm | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 30.000 cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.000 cm | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 9.849 kg | 9.891kg | 10.39kg | 9.86kg |
Unit Type of Package 3 | P06 | PAL | P06 | PAL |
Number of Units in Package 3 | 160 | 160 | 160 | 160 |
Package 3 Height | 75.000 cm | 75.0cm | 77.0cm | 75.0cm |
Package 3 Width | 60.000 cm | 60.0cm | 80.0cm | 60.0cm |
Package 3 Length | 80.000 cm | 80.0cm | 60.0cm | 80.0cm |
Package 3 Weight | 165.408kg | 163.68 kg | 174.74 kg | 163.68 kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||||
Part Number | LC1D65AE7C | LC1D65AF7C | LC1D65AM7C | LC1D65AQ7C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Rated operating current [Ie] | 80 A 60 °C) at <= 440 V AC AC-1 for power circuit 65 A 60 °C) at <= 440 V AC AC-3 for power circuit 65 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-1 for power circuit 65 A 60 °C) at <= 440 V AC AC-3 for power circuit 65 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-1 for power circuit 65 A 60 °C) at <= 440 V AC AC-3 for power circuit 65 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-1 for power circuit 65 A 60 °C) at <= 440 V AC AC-3 for power circuit 65 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 48 V AC 50/60 Hz | 110V AC 50/60Hz | 230V AC 50/60Hz | 380 V AC 50/60 Hz |
Additional information | ||||
Motor power (kW) | 37 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3) 30 kW at 380/400 V AC 50/60 Hz (AC-3) 37 kW at 660/690 V AC 50/60 Hz (AC-3) 37 kW at 415/440 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 30 kW at 380/400 V AC 50/60 Hz (AC-3e) 37 kW at 660/690 V AC 50/60 Hz (AC-3e) 37 kW at 415/440 V AC 50/60 Hz (AC-3e) |
37 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3) 30 kW at 380/400 V AC 50/60 Hz (AC-3) 37 kW at 660/690 V AC 50/60 Hz (AC-3) 37 kW at 415/440 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 30 kW at 380/400 V AC 50/60 Hz (AC-3e) 37 kW at 660/690 V AC 50/60 Hz (AC-3e) 37 kW at 415/440 V AC 50/60 Hz (AC-3e) |
37 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3) 30 kW at 380/400 V AC 50/60 Hz (AC-3) 37 kW at 660/690 V AC 50/60 Hz (AC-3) 37 kW at 415/440 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 30 kW at 380/400 V AC 50/60 Hz (AC-3e) 37 kW at 660/690 V AC 50/60 Hz (AC-3e) 37 kW at 415/440 V AC 50/60 Hz (AC-3e) |
37 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3) 30 kW at 380/400 V AC 50/60 Hz (AC-3) 37 kW at 660/690 V AC 50/60 Hz (AC-3) 37 kW at 415/440 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 30 kW at 380/400 V AC 50/60 Hz (AC-3e) 37 kW at 660/690 V AC 50/60 Hz (AC-3e) 37 kW at 415/440 V AC 50/60 Hz (AC-3e) |
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
protection cap | None | None | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 80 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 80 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 80 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 80 A at <60 °C for power circuits |
Rated short-time withstand current [Icw] | 520 A at <40 °C – 10 s for power circuit 900 A at <40 °C – 1 s for power circuit 110 A at <40 °C – 10 min for power circuit 260 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
520 A at <40 °C – 10 s for power circuit 900 A at <40 °C – 1 s for power circuit 110 A at <40 °C – 10 min for power circuit 260 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
520 A at <40 °C – 10 s for power circuit 900 A at <40 °C – 1 s for power circuit 110 A at <40 °C – 10 min for power circuit 260 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
520 A at <40 °C – 10 s for power circuit 900 A at <40 °C – 1 s for power circuit 110 A at <40 °C – 10 min for power circuit 260 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 125 A gG at <= 690 V for type 2 for power circuits 160 A gG for at <= 690 V for type 1 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 125 A gG at <= 690 V for type 2 for power circuits 160 A gG for at <= 690 V for type 1 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 125 A gG at <= 690 V for type 2 for power circuits 160 A gG for at <= 690 V for type 1 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 125 A gG at <= 690 V for type 2 for power circuits 160 A gG for at <= 690 V for type 1 for power circuits |
average impedance | 1.5 mΩ – Ith 80 A 50 Hz for power circuits | 1.5 mΩ – Ith 80 A 50 Hz for power circuits | 1.5 mΩ – Ith 80 A 50 Hz for power circuits | 1.5 mΩ – Ith 80 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 6 Mcycles | 6 Mcycles | 6 Mcycles | 6 Mcycles |
Electrical life | 1.5 Mcycles 65 A AC-3 Ue <= 440 V 2.5 Mcycles 42 A AC-3 Ue 660/690 V 1.3 Mcycles 80 A AC-1 Ue <= 440 V 1.5 Mcycles 65 A AC-3e Ue <= 440 V at 2.5 Mcycles 42 A AC-3e at 660/690 V at Ue |
1.5 Mcycles 65 A AC-3 Ue <= 440 V 2.5 Mcycles 42 A AC-3 Ue 660/690 V 1.3 Mcycles 80 A AC-1 Ue <= 440 V 1.5 Mcycles 65 A AC-3e Ue <= 440 V at 2.5 Mcycles 42 A AC-3e at 660/690 V at Ue |
1.5 Mcycles 65 A AC-3 Ue <= 440 V 2.5 Mcycles 42 A AC-3 Ue 660/690 V 1.3 Mcycles 80 A AC-1 Ue <= 440 V 1.5 Mcycles 65 A AC-3e Ue <= 440 V at 2.5 Mcycles 42 A AC-3e at 660/690 V at Ue |
1.5 Mcycles 65 A AC-3 Ue <= 440 V 2.5 Mcycles 42 A AC-3 Ue 660/690 V 1.3 Mcycles 80 A AC-1 Ue <= 440 V 1.5 Mcycles 65 A AC-3e Ue <= 440 V at 2.5 Mcycles 42 A AC-3e at 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
(~50Hz hold) power consumption (VA) | 13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
heat dissipation | 4…5 W at 50/60 Hz | 4…5 W at 50/60 Hz | 4…5 W at 50/60 Hz | 4…5 W at 50/60 Hz |
action time | 4…19 ms open 12…26 ms close |
4…19 ms open 12…26 ms close |
4…19 ms open 12…26 ms close |
4…19 ms open 12…26 ms close |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option : flexible wire with wire terminal Terminal Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit: screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal |
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option : flexible wire with wire terminal Terminal Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit: screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal |
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option : flexible wire with wire terminal Terminal Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit: screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal |
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option : flexible wire with wire terminal Terminal Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit: screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal |
Tightening torque | Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6 power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6 power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6 power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6 power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | DIN rail installation base plate installation |
Chassis mounting rail installation |
Chassis mounting rail installation |
DIN rail installation base plate installation |
environment | ||||
standard | IEC 60947-4-1 GB 14048.4 |
GB 14048.4 IEC 60947-4-1 |
GB 14048.4 IEC 60947-4-1 |
GB 14048.4 IEC 60947-4-1 |
certified product | CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
high | 122mm | 122mm | 122mm | 122mm |
width | 55mm | 55 mm | 55 mm | 55mm |
depth | 120 mm | 120 mm | 120 mm | 120 mm |
Product Weight | 0.86 kg | 0.86 kg | 0.86 kg | 0.86 kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 6.6cm | 6.6cm | 6.5cm | 6.022 cm |
Package 1 Width | 14.3 cm | 13.7cm | 13.9 cm | 13.578 cm |
Package 1 Length | 15.6cm | 16.0cm | 15.8 cm | 15.031 cm |
Package 1 Weight | 983.72g | 981.06g | 975.75g | 956.1g |
Unit Type of Package 2 | S02 | S02 | S02 | S02 |
Number of Units in Package 2 | 10 | 10 | 10 | 10 |
Package 2 Height | 15.0cm | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 30.0cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.0cm | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 9.994kg | 9.957kg | 9.952kg | 10.0 kg |
Unit Type of Package 3 | PAL | PAL | PAL | PAL |
Number of Units in Package 3 | 160 | 160 | 160 | 160 |
Package 3 Height | 75.0cm | 75.0cm | 75.0cm | 75.0cm |
Package 3 Width | 60.0cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Weight | 163.68 kg | 163.68 kg | 160.896kg | 162.496 kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||||
Part Number | LC1D65B7C | LC1D65F7C | LC1D65M7C | LC1D65Q7C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Rated operating current [Ie] | 80 A 60 °C) at <= 440 V AC AC-1 for power circuit 65 A 60 °C) at <= 440 V AC AC-3 for power circuit 65 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-1 for power circuit 65 A 60 °C) at <= 440 V AC AC-3 for power circuit 65 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-1 for power circuit 65 A 60 °C) at <= 440 V AC AC-3 for power circuit 65 A 60 °C) at< = 440 V AC AC-3e for power circuit |
80 A 60 °C) at <= 440 V AC AC-1 for power circuit 65 A 60 °C) at <= 440 V AC AC-3 for power circuit 65 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 24 V AC 50/60 Hz | 110V AC 50/60Hz | 230V AC 50/60Hz | 380 V AC 50/60 Hz |
Additional information | ||||
Motor power (kW) | 37 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3) 30 kW at 380/400 V AC 50/60 Hz (AC-3) 37 kW at 660/690 V AC 50/60 Hz (AC-3) 37 kW at 415/440 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 30 kW at 380/400 V AC 50/60 Hz (AC-3e) 37 kW at 660/690 V AC 50/60 Hz (AC-3e) 37 kW at 415/440 V AC 50/60 Hz (AC-3e) |
37 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3) 30 kW at 380/400 V AC 50/60 Hz (AC-3) 37 kW at 660/690 V AC 50/60 Hz (AC-3) 37 kW at 415/440 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 30 kW at 380/400 V AC 50/60 Hz (AC-3e) 37 kW at 660/690 V AC 50/60 Hz (AC-3e) 37 kW at 415/440 V AC 50/60 Hz (AC-3e) |
11 kW at 400 V AC 50/60 Hz (AC-4) 37 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 220/240 V AC 50/60 Hz (AC -3) 30 kW at 380/400 V AC 50/60 Hz (AC-3) 37 kW at 660/690 V AC 50/60 Hz (AC-3) 37 kW at 415/440 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 30 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 37 kW at 660/690 V AC 50/60 Hz (AC-3e) 37 kW at 415/440 V AC 50/60 Hz (AC -3e) |
11 kW at 400 V AC 50/60 Hz (AC-4) 37 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 220/240 V AC 50/60 Hz (AC -3) 30 kW at 380/400 V AC 50/60 Hz (AC-3) 37 kW at 660/690 V AC 50/60 Hz (AC-3) 37 kW at 415/440 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 220/240 V AC 50/60 Hz (AC-3e) 30 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 37 kW at 660/690 V AC 50/60 Hz (AC-3e) 37 kW at 415/440 V AC 50/60 Hz (AC -3e) |
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
protection cap | None | None | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 80 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 80 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 80 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 80 A at <60 °C for power circuits |
Rated short-time withstand current [Icw] | 520 A at <40 °C – 10 s for power circuit 900 A at <40 °C – 1 s for power circuit 110 A at <40 °C – 10 min for power circuit 260 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
520 A at <40 °C – 10 s for power circuit 900 A at <40 °C – 1 s for power circuit 110 A at <40 °C – 10 min for power circuit 260 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
520 A at <40 °C – 10 s for power circuit 900 A at <40 °C – 1 s for power circuit 110 A at <40 °C – 10 min for power circuit 260 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
520 A at <40 °C – 10 s for power circuit 900 A at <40 °C – 1 s for power circuit 110 A at <40 °C – 10 min for power circuit 260 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 125 A gG at <= 690 V for type 2 for power circuits 160 A gG for at <= 690 V for type 1 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 125 A gG at <= 690 V for type 2 for power circuits 160 A gG for at <= 690 V for type 1 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 125 A gG at <= 690 V for type 2 for power circuits 160 A gG for at <= 690 V for type 1 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 125 A gG at <= 690 V for type 2 for power circuits 160 A gG for at <= 690 V for type 1 for power circuits |
average impedance | 1 mΩ – Ith 80 A 50 Hz for power circuits | 1 mΩ – Ith 80 A 50 Hz for power circuits | 1 mΩ – Ith 80 A 50 Hz for power circuits | 1 mΩ – Ith 80 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 1000 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 1000 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 1000 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 1000 V conforming to IEC 60947-4-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 6 Mcycles | 6 Mcycles | 6 Mcycles | 6 Mcycles |
Electrical life | 1.5 Mcycles 80 A AC-1 Ue <= 440 V 1.5 Mcycles 65 A AC-3 Ue <= 440 V 2.5 Mcycles 42 A AC-3 Ue 660/690 V 1.5 Mcycles 65 A AC-3e Ue <= 440 V at 2.5 Mcycles 42 A AC-3e at 660/690 V at Ue |
1.5 Mcycles 80 A AC-1 Ue <= 440 V 1.5 Mcycles 65 A AC-3 Ue <= 440 V 2.5 Mcycles 42 A AC-3 Ue 660/690 V 1.5 Mcycles 65 A AC-3e Ue <= 440 V at 2.5 Mcycles 42 A AC-3e at 660/690 V at Ue |
1.5 Mcycles 80 A AC-1 Ue <= 440 V 1.5 Mcycles 65 A AC-3 Ue <= 440 V 2.5 Mcycles 42 A AC-3 Ue 660/690 V 1.5 Mcycles 65 A AC-3e Ue <= 440 V at 2.5 Mcycles 42 A AC-3e at 660/690 V at Ue |
1.5 Mcycles 80 A AC-1 Ue <= 440 V 1.5 Mcycles 65 A AC-3 Ue <= 440 V 2.5 Mcycles 42 A AC-3 Ue 660/690 V 1.5 Mcycles 65 A AC-3e Ue <= 440 V at 2.5 Mcycles 42 A AC-3e at 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
(~50Hz hold) power consumption (VA) | 26 VA 60 Hz 0.3 20 °C) 26 VA 50 Hz 0.3 20 °C) |
26 VA 60 Hz 0.3 20 °C) 26 VA 50 Hz 0.3 20 °C) |
26 VA 60 Hz 0.3 20 °C) 26 VA 50 Hz 0.3 20 °C) |
26 VA 60 Hz 0.3 20 °C) 26 VA 50 Hz 0.3 20 °C) |
heat dissipation | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz |
action time | 20…26 ms close 8…12 ms break |
20…26 ms close 8…12 ms break |
20…26 ms close 8…12 ms break |
20…26 ms close 8…12 ms break |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals Control circuit: Bolt fastening1 1…2.5 mm² Cable option: Flexible wire with wire terminals Power circuit: Terminal1 2.5…25 mm² Lug Ø: 13 mm Cable option Type: Flexible cord without wire terminals Power circuit: Terminal 2 2.5…16 mm² lug Outer diameter Ø: 13 mm Cable selection: Flexible cord without wire terminals Power circuit: Terminal 1 2.5…25 mm² lug Outer diameter Ø: 13 mm Cable option: Flexible cord with wire terminals Power circuit: Terminal 2 2.5…10 mm² Lug outer diameter Ø: 13 mm Cable option: Flexible cord with bar terminals Power circuit: Terminal 1 2.5…25 mm² O.D. of lug Ø: 13 mm Cable option: Solid without wire terminal Power circuit: terminal 2 2.5…16 mm² O.D. of lug: 13 mm Cable option: Solid without wire wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals Control circuit: Bolt fastening1 1…2.5 mm² Cable option: Flexible wire with wire terminals Power circuit: Terminal1 2.5…25 mm² Lug Ø: 13 mm Cable option Type: Flexible cord without wire terminals Power circuit: Terminal 2 2.5…16 mm² lug Outer diameter Ø: 13 mm Cable selection: Flexible cord without wire terminals Power circuit: Terminal 1 2.5…25 mm² lug Outer diameter Ø: 13 mm Cable option: Flexible cord with wire terminals Power circuit: Terminal 2 2.5…10 mm² Lug outer diameter Ø: 13 mm Cable option: Flexible cord with bar terminals Power circuit: Terminal 1 2.5…25 mm² O.D. of lug Ø: 13 mm Cable option: Solid without wire terminal Power circuit: terminal 2 2.5…16 mm² O.D. of lug: 13 mm Cable option: Solid without wire wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals Control circuit: Bolt fastening1 1…2.5 mm² Cable option: Flexible wire with wire terminals Power circuit: Terminal1 2.5…25 mm² Lug Ø: 13 mm Cable option Type: Flexible cord without wire terminals Power circuit: Terminal 2 2.5…16 mm² lug Outer diameter Ø: 13 mm Cable selection: Flexible cord without wire terminals Power circuit: Terminal 1 2.5…25 mm² lug Outer diameter Ø: 13 mm Cable option: Flexible cord with wire terminals Power circuit: Terminal 2 2.5…10 mm² Lug outer diameter Ø: 13 mm Cable option: Flexible cord with bar terminals Power circuit: Terminal 1 2.5…25 mm² O.D. of lug Ø: 13 mm Cable option: Solid without wire terminal Power circuit: terminal 2 2.5…16 mm² O.D. of lug: 13 mm Cable option: Solid without wire wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals Control circuit: Bolt fastening1 1…2.5 mm² Cable option: Flexible wire with wire terminals Power circuit: Terminal1 2.5…25 mm² Lug Ø: 13 mm Cable option Type: Flexible cord without wire terminals Power circuit: Terminal 2 2.5…16 mm² lug Outer diameter Ø: 13 mm Cable selection: Flexible cord without wire terminals Power circuit: Terminal 1 2.5…25 mm² lug Outer diameter Ø: 13 mm Cable option: Flexible cord with wire terminals Power circuit: Terminal 2 2.5…10 mm² Lug outer diameter Ø: 13 mm Cable option: Flexible cord with bar terminals Power circuit: Terminal 1 2.5…25 mm² O.D. of lug Ø: 13 mm Cable option: Solid without wire terminal Power circuit: terminal 2 2.5…16 mm² O.D. of lug: 13 mm Cable option: Solid without wire wire terminal |
Tightening torque | Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 5 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 5 Nm Via cable connector with screwdriver Ø 8 Slotted screw: M6 Power circuit: 5 Nm Via cable connector with screwdriver No. 3 Phillips screw: M6 Control circuit: 1.2 Nm Via bolt fastening with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm by bolting with screwdriver Ø 6 flat control circuit: 1.2 Nm by bolting with screwdriver No 2 Phillips screw Power circuit: 5 Nm by bolting with screwdriver Ø 6…8 mm Slotted power supply Circuit: 5 Nm Via cable connector with screwdriver Ø 8 Slotted screw: M6 Power circuit: 5 Nm Via cable connector with screwdriver No. 3 Phillips screw: M6 Control circuit: 1.2 Nm Via bolt fastening with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm by bolting with screwdriver Ø 6 flat control circuit: 1.2 Nm by bolting with screwdriver No 2 Phillips screw Power circuit: 5 Nm by bolting with screwdriver Ø 6…8 mm Slotted power supply Circuit: 5 Nm Via cable connector with screwdriver Ø 8 Slotted screw: M6 Power circuit: 5 Nm Via cable connector with screwdriver No. 3 Phillips screw: M6 Control circuit: 1.2 Nm Via bolt fastening with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 5 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 5 Nm Via cable connector with screwdriver Ø 8 Slotted screw: M6 Power circuit: 5 Nm Via cable connector with screwdriver No. 3 Phillips screw: M6 Control circuit: 1.2 Nm Via bolt fastening with screwdriver pozidriv No 2 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | DIN rail installation base plate installation |
Chassis mounting rail installation |
DIN rail installation base plate installation |
DIN rail installation base plate installation |
environment | ||||
standard | GB 14048.4 IEC 60947-4-1 |
IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 GB 14048.4 |
certified product | CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
Shock and vibration resistance | Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
high | 127 mm | 127 mm | 127 mm | 127 mm |
width | 75 mm | 75 mm | 75 mm | 75 mm |
depth | 119mm | 119 mm | 119mm | 119mm |
Product Weight | 1.4kg | 1.4kg | 1.4kg | 1.4kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 14.2 cm | 10.4 cm | 10.0cm | 10.366 cm |
Package 1 Width | 11.1 cm | 14.0cm | 14.1 cm | 13.791 cm |
Package 1 Length | 14.5cm | 14.3 cm | 14.2 cm | 14.098 cm |
Package 1 Weight | 1330.21g | 1.341kg | 1.341kg | 1.331kg |
Unit Type of Package 2 | S03 | S03 | S03 | S03 |
Number of Units in Package 2 | 12 | 12 | 12 | 12 |
Package 2 Height | 30.0cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Width | 30.0cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.0cm | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 16.52kg | 16.55kg | 16.611kg | 16.57kg |
Unit Type of Package 3 | P06 | P06 | P06 | P06 |
Number of Units in Package 3 | 96 | 96 | 96 | 96 |
Package 3 Height | 75.0cm | 75.0cm | 75.0cm | 75.0cm |
Package 3 Width | 60.0cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Weight | 142.16 kg | 142.4 kg | 142.888 kg | 142.56kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)