SIMATIC S7-1500 – SM 531 Analog Input Modules – Siemens Analog Modules

USD $ 524.57USD $ 1,176.54

SKU: N/A

Analog input modules record process signals such as pressure or temperature and forward them in digitalized format (16-bit format) to the PLC. They are suitable for measuring current (2-wire and 4-wire transducers), voltage, and resistance, as well as for the connection of resistance thermometers and thermocouples (measurement types depend on the module).

The following analog input modules are available:

  • AI 8xU/I/R/RTD BA
    Analog input module with 8 channels; 16-bit resolution; accuracy +/-0.5%; one potential group; 4 V common mode voltage; parameterizable diagnostics; hardware interrupts (two upper and lower limit values); 8 channels RTD.
    Module width 35 mm
  • AI 16xI BA;
    Analog input module with 16 channels; 16-bit resolution; accuracy +/-0.5%; one potential group; 8 V common mode voltage; parameterizable diagnostics; hardware interrupts (two upper and lower limit values); 16 channels for current measurement.
    Module width 35 mm
  • AI 16xU BA;
    Analog input module with 16 channels; 16-bit resolution; accuracy +/-0.5%; one potential group; 8 V common mode voltage; parameterizable diagnostics; hardware interrupts (two upper and lower limit values); 16 channels for voltage measurement (measuring ranges from +/- 1V).
    Module width 35 mm
  • AI 4xU/I/RTD/TC ST
    Analog input module with 4 channels; 16 bit resolution; accuracy +/-0.3 %; one potential group; 10 V common mode voltage; parameterizable diagnostics; hardware interrupts (two upper and lower limit values); calibration during runtime.
    Module width 25 mm
  • AI 8xU/I/RTD/TC ST
    Analog input module with 8 channels (4 channels for R/RTD measurement); 16-bit resolution; accuracy +/-0.3%; one potential group; 10 V common mode voltage; parameterizable diagnostics; hardware interrupts (two upper and lower limit values); calibration during runtime.
    Module width 35 mm
  • AI 8xU/I HS
    Analog input module with 8 channels; 16-bit resolution; accuracy +/-0.3%; one potential group; 10 V common mode voltage; parameterizable diagnostics; hardware interrupts (two upper and lower limit values); high-speed module with 8 channels in 125 µs; isochronous mode; calibration during runtime.
    Module width 35 mm
  • AI 8xU/R/RTD/TC HF
    Analog input module with 8 channels; 16-bit resolution; accuracy +/-0.1%; one potential group; 30 V AC / 60 V DC common-mode voltage; parameterizable diagnostics; hardware interrupts (two upper and lower limit values); calibration during runtime; characteristic linearization according to GOST 9. Channel for TC compensation or “real” measurement channel; fast mode.
    Module width 35 mm
  • AI 8xU/I HF
    Analog input module with 8 channels; 16-bit resolution; accuracy +/-0.1%; one potential group; 30 V AC / 60 V DC common mode voltage; parameterizable diagnostics; hardware interrupts (two upper and lower limit values); calibration during runtime.
    Module width 35 mm

Siemens Analog Modules S7-1500 Product Specifications:

Article number 6ES7531-7QD00-0AB0 6ES7531-7KF00-0AB0 6ES7531-7NF10-0AB0 6ES7531-7NF00-0AB0
S7-1500, AI 4xU/I/RTD/TC ST S7-1500, AI 8xU/I/RTD/TC ST S7-1500, AI 8xU/I HS S7-1500, AI 8xU/I HF
General information
Product type designation AI 4xU/I/RTD/TC ST AI 8xU/I/RTD/TC ST AI 8xU/I HS AI 8xU/I HF
HW functional status From FS01 FS04 From FS01 From FS01
Firmware version V1.0.0 V2.0.0 V2.1.0 V1.1.0
● FW update possible Yes Yes Yes Yes
Product function
● I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3
● Isochronous mode No No Yes No
● Prioritized startup No No Yes Yes
● Measuring range scalable No No No No
● Scalable measured values No No No Yes
● Adjustment of measuring range No No No Yes
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V13 / V13.0.2 V12 / V12 V14 / – V14 / –
● STEP 7 configurable/integrated from version V5.5 SP3 / – V5.5 SP3 / – V5.5 SP3 / – V5.5 SP3 / –
● PROFIBUS from GSD version/GSD revision V1.0 / V5.1 V1.0 / V5.1 V1.0 / V5.1 V1.0 / V5.1
● PROFINET from GSD version/GSD revision V2.3 / – V2.3 / – V2.3 / – V2.3 / –
Operating mode
● Oversampling No No Yes No
● MSI Yes Yes Yes Yes
CiR – Configuration in RUN
Reparameterization possible in RUN Yes Yes Yes Yes
Calibration possible in RUN Yes Yes Yes Yes
Supply voltage
Rated value (DC) 24 V 24 V 24 V 24 V
permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V
Reverse polarity protection Yes Yes Yes Yes
Input current
Current consumption, max. 165 mA 240 mA; with 24 V DC supply 240 mA; with 24 V DC supply 50 mA; with 24 V DC supply
Encoder supply
24 V encoder supply
● Short-circuit protection Yes Yes Yes
● Output current, max. 20 mA; Max. 47 mA per channel for a duration < 10 s 20 mA; Max. 47 mA per channel for a duration < 10 s 20 mA; Max. 47 mA per channel for a duration < 10 s
Power
Power available from the backplane bus 0.7 W 0.7 W 1.15 W 0.85 W
Power loss
Power loss, typ. 2.3 W 2.7 W 3.4 W 1.9 W
Analog inputs
Number of analog inputs 4 8 8 8
● For current measurement 4 8 8 8
● For voltage measurement 4 8 8 8
● For resistance/resistance thermometer measurement 2 4
● For thermocouple measurement 4 8
permissible input voltage for voltage input (destruction limit), max. 28.8 V 28.8 V 28.8 V 28.8 V
permissible input current for current input (destruction limit), max. 40 mA 40 mA 40 mA 40 mA
Constant measurement current for resistance-type transmitter, typ. 150 Ohm, 300 Ohm, 600 Ohm, Pt100, Pt200, Ni100: 1.25 mA; 6 000 Ohm, Pt500, Pt1000, Ni1000, LG-Ni1000: 0.625 mA; PTC: 0.472 mA 150 Ohm, 300 Ohm, 600 Ohm, Pt100, Pt200, Ni100: 1.25 mA; 6 000 Ohm, Pt500, Pt1000, Ni1000, LG-Ni1000: 0.625 mA; PTC: 0.472 mA
Technical unit for temperature measurement adjustable Yes; °C/°F/K Yes; °C/°F/K
Analog input with oversampling No
Standardization of measured values No
Input ranges (rated values), voltages
● 0 to +5 V No No No No
● 0 to +10 V No No No No
● 1 V to 5 V Yes Yes Yes Yes
— Input resistance (1 V to 5 V) 100 kΩ 100 kΩ 50 kΩ 100 kΩ
● -1 V to +1 V Yes Yes
— Input resistance (-1 V to +1 V) 10 MΩ 10 MΩ
● -10 V to +10 V Yes Yes Yes Yes
— Input resistance (-10 V to +10 V) 100 kΩ 100 kΩ 100 kΩ 100 kΩ
● -2.5 V to +2.5 V Yes Yes No Yes
— Input resistance (-2.5 V to +2.5 V) 10 MΩ 10 MΩ 100 kΩ
● -25 mV to +25 mV No No No No
● -250 mV to +250 mV Yes Yes No No
— Input resistance (-250 mV to +250 mV) 10 MΩ 10 MΩ
● -5 V to +5 V Yes Yes Yes Yes
— Input resistance (-5 V to +5 V) 100 kΩ 100 kΩ 50 kΩ 100 kΩ
● -50 mV to +50 mV Yes Yes No No
— Input resistance (-50 mV to +50 mV) 10 MΩ 10 MΩ
● -500 mV to +500 mV Yes Yes No No
— Input resistance (-500 mV to +500 mV) 10 MΩ 10 MΩ
● -80 mV to +80 mV Yes Yes No No
— Input resistance (-80 mV to +80 mV) 10 MΩ 10 MΩ
Input ranges (rated values), currents
● 0 to 20 mA Yes Yes Yes Yes
— Input resistance (0 to 20 mA) 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC 41 Ω; Plus approx. 42 ohms for overvoltage protection by PTC 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
● -20 mA to +20 mA Yes Yes Yes Yes
— Input resistance (-20 mA to +20 mA) 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC 41 Ω; Plus approx. 42 ohms for overvoltage protection by PTC 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
● 4 mA to 20 mA Yes Yes Yes Yes
— Input resistance (4 mA to 20 mA) 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC 41 Ω; Plus approx. 42 ohms for overvoltage protection by PTC 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Input ranges (rated values), thermocouples
● Type B Yes Yes No No
— Input resistance (Type B) 10 MΩ 10 MΩ
● Type C No No No No
● Type E Yes Yes No No
— Input resistance (Type E) 10 MΩ 10 MΩ
● Type J Yes Yes No No
— Input resistance (type J) 10 MΩ 10 MΩ
● Type K Yes Yes No No
— Input resistance (Type K) 10 MΩ 10 MΩ
● Type L No No No No
● Type N Yes Yes No No
— Input resistance (Type N) 10 MΩ 10 MΩ
● Type R Yes Yes No No
— Input resistance (Type R) 10 MΩ 10 MΩ
● Type S Yes Yes No No
— Input resistance (Type S) 10 MΩ 10 MΩ
● Type T Yes Yes No No
— Input resistance (Type T) 10 MΩ 10 MΩ
● Type U No
● Type TXK/TXK(L) to GOST No No No No
Input ranges (rated values), resistance thermometer
● Cu 10 No No No No
● Cu 10 according to GOST No No No No
● Cu 50 No No No No
● Cu 50 according to GOST No No No No
● Cu 100 No No No No
● Cu 100 according to GOST No No No No
● Ni 10 No No No No
● Ni 10 according to GOST No No No No
● Ni 100 Yes; Standard/climate Yes; Standard/climate No No
— Input resistance (Ni 100) 10 MΩ 10 MΩ
● Ni 100 according to GOST No No No No
● Ni 1000 Yes; Standard/climate Yes; Standard/climate No No
— Input resistance (Ni 1000) 10 MΩ 10 MΩ
● Ni 1000 according to GOST No No No No
● LG-Ni 1000 Yes; Standard/climate Yes; Standard/climate No No
— Input resistance (LG-Ni 1000) 10 MΩ 10 MΩ
● Ni 120 No No No No
● Ni 120 according to GOST No No No No
● Ni 200 No No No
● Ni 200 according to GOST No No No No
● Ni 500 No No No No
● Ni 500 according to GOST No No No No
● Pt 10 No No No No
● Pt 10 according to GOST No No No No
● Pt 50 No No No No
● Pt 50 according to GOST No No No No
● Pt 100 Yes; Standard/climate Yes; Standard/climate No No
— Input resistance (Pt 100) 10 MΩ 10 MΩ
● Pt 100 according to GOST No No No No
● Pt 1000 Yes; Standard/climate Yes; Standard/climate No No
— Input resistance (Pt 1000) 10 MΩ 10 MΩ
● Pt 1000 according to GOST No No No No
● Pt 200 Yes; Standard/climate Yes; Standard/climate No No
— Input resistance (Pt 200) 10 MΩ 10 MΩ
● Pt 200 according to GOST No No No No
● Pt 500 Yes; Standard/climate Yes; Standard/climate No No
— Input resistance (Pt 500) 10 MΩ 10 MΩ
● Pt 500 according to GOST No No No No
Input ranges (rated values), resistors
● 0 to 150 ohms Yes Yes No No
— Input resistance (0 to 150 ohms) 10 MΩ 10 MΩ
● 0 to 300 ohms Yes Yes No No
— Input resistance (0 to 300 ohms) 10 MΩ 10 MΩ
● 0 to 600 ohms Yes Yes No No
— Input resistance (0 to 600 ohms) 10 MΩ 10 MΩ
● 0 to 3000 ohms No No No No
● 0 to 6000 ohms Yes Yes No No
— Input resistance (0 to 6000 ohms) 10 MΩ 10 MΩ
● PTC Yes Yes No No
— Input resistance (PTC) 10 MΩ 10 MΩ
Thermocouple (TC)
Temperature compensation
— parameterizable Yes Yes
— internal temperature compensation Yes Yes
— external temperature compensation via RTD Yes Yes
— Compensation for 0 °C reference point temperature Yes; fixed value can be set Yes; fixed value can be set
— Reference channel of the module No Yes
Cable length
● shielded, max. 800 m; for U/I, 200 m for R/RTD, 50 m for TC 800 m; for U/I, 200 m for R/RTD, 50 m for TC 800 m 800 m
Analog value generation for the inputs
Measurement principle
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 16 bit 16 bit 16 bit 24 bit; When using the function “Scaling of the measured values” or “Measuring range adaptation” (32 bit REAL format); 16 bit when using the S7 format (16 bit INTEGER)
● Integration time, parameterizable Yes Yes Yes
● Integration time (ms) 2,5 / 16,67 / 20 / 100 ms 2,5 / 16,67 / 20 / 100 ms Fast mode: 2.5 / 16.67 / 20 / 100 ms, standard mode: 7.5 / 50 / 60 / 300 ms
● Basic conversion time, including integration time (ms) 9 / 23 / 27 / 107 ms 9 / 23 / 27 / 107 ms Fast mode: 4 / 18 / 22 / 102 ms; Standard mode: 9 / 52 / 62 / 302 ms
— additional conversion time for wire-break monitoring 9 ms (to be considered in R/RTD/TC measurement) 9 ms (to be considered in R/RTD/TC measurement)
— additional conversion time for resistance measurement 150 ohm, 300 ohm, 600 ohm, Pt100, Pt200, Ni100: 2 ms, 6000 ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms 150 ohm, 300 ohm, 600 ohm, Pt100, Pt200, Ni100: 2 ms, 6000 ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms
● Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 / 10 400 / 60 / 50 / 10 Hz 400 / 60 / 50 / 10 Hz
● Basic execution time of the module (all channels released) 62.5 µs; independent of number of activated channels Corresponds to the channel with the highest basic conversion time
● Time for offset calibration (per module) Basic conversion time of the slowest channel Basic conversion time of the slowest channel
Smoothing of measured values
● parameterizable Yes Yes Yes Yes
● Step: None Yes Yes Yes Yes
● Step: low Yes Yes Yes Yes
● Step: Medium Yes Yes Yes Yes
● Step: High Yes Yes Yes Yes
Encoder
Connection of signal encoders
● for voltage measurement Yes Yes Yes Yes
● for current measurement as 2-wire transducer Yes Yes Yes Yes; with external transmitter supply
— Burden of 2-wire transmitter, max. 820 Ω 820 Ω 820 Ω
● for current measurement as 4-wire transducer Yes Yes Yes Yes
● for resistance measurement with two-wire connection Yes; Only for PTC Yes; Only for PTC No No
● for resistance measurement with three-wire connection Yes; All measuring ranges except PTC; internal compensation of the cable resistances Yes; All measuring ranges except PTC; internal compensation of the cable resistances No No
● for resistance measurement with four-wire connection Yes; All measuring ranges except PTC Yes; All measuring ranges except PTC No No
Errors/accuracies
Linearity error (relative to input range), (+/-) 0.02 % 0.02 % 0.02 % 0.02 %
Temperature error (relative to input range), (+/-) 0.005 %/K; With TC type T 0.02 ± % / K 0.005 %/K; With TC type T 0.02 ± % / K 0.005 %/K 0.005 %/K
Crosstalk between the inputs, max. -80 dB -80 dB -60 dB -80 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) 0.02 % 0.02 % 0.02 % 0.02 %
Temperature error of internal compensation ±6 °C ±6 °C
note regarding accuracy at temperatures below 0 °C, the figures for operating error and temperature error are doubled at temperatures below 0 °C, the figures for operating error and temperature error are doubled
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-) 0.3 % 0.3 % 0.3 % 0.1 %
● Current, relative to input range, (+/-) 0.3 % 0.3 % 0.3 % 0.1 %
● Resistance, relative to input range, (+/-) 0.3 % 0.3 %
● Resistance thermometer, relative to input range, (+/-) 0.3 %; Ptxxx standard: ±1.5 K, Ptxxx climate: ±0.5 K, Nixxx standard: ±0.5 K, Nixxx climate: ±0.3 K Ptxxx standard: ±1.5 K, Ptxxx climate: ±0.5 K, Nixxx standard: ±0.5 K, Nixxx climate: ±0.3 K
● Thermocouple, relative to input range, (+/-) 0.3 %; Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5 K, type J: > -210 °C ±1.9 K, type K: > -200 °C ±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C ±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C ±2.4 K Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5 K, type J: > -210 °C ±1.9 K, type K: > -200 °C ±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C ±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C ±2.4 K
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-) 0.1 % 0.1 % 0.2 % 0.05 %
● Current, relative to input range, (+/-) 0.1 % 0.1 % 0.2 % 0.05 %
● Resistance, relative to input range, (+/-) 0.1 % 0.1 %
● Resistance thermometer, relative to input range, (+/-) 0.1 %; Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K
● Thermocouple, relative to input range, (+/-) 0.1 %; Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of interference < rated value of input range), min. 40 dB 40 dB 80 dB; in the Standard operating mode, 40 dB in the Fast operating mode
● Common mode voltage, max. 10 V 10 V 10 V 60 V DC/30 V AC
● Common mode interference, min. 60 dB 60 dB 50 dB at 400 Hz; 60 dB at 60 / 50 / 10 Hz 80 dB
Isochronous mode
Filtering and processing time (TCI), min. 80 µs
Bus cycle time (TDP), min. 250 µs
Interrupts/diagnostics/status information
Diagnostics function Yes Yes Yes Yes
Alarms
● Diagnostic alarm Yes Yes Yes Yes
● Limit value alarm Yes; two upper and two lower limit values in each case Yes; two upper and two lower limit values in each case Yes; two upper and two lower limit values in each case Yes; two upper and two lower limit values in each case
Diagnoses
● Monitoring the supply voltage Yes Yes Yes Yes
● Wire-break Yes; Only for 1 to 5 V, 4 to 20 mA, TC, R, and RTD Yes; Only for 1 to 5 V, 4 to 20 mA, TC, R, and RTD Yes; only for 1 … 5 V and 4 … 20 mA Yes; only for 1 … 5 V and 4 … 20 mA
● Short-circuit
● Group error
● Overflow/underflow Yes Yes Yes Yes
Diagnostics indication LED
● RUN LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED
● ERROR LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED
● MAINT LED
● Monitoring of the supply voltage (PWR-LED) Yes; green LED Yes; green LED Yes; green LED Yes; green LED
● Channel status display Yes; green LED Yes; green LED Yes; green LED Yes; green LED
● for channel diagnostics Yes; red LED Yes; red LED Yes; red LED Yes; red LED
● for module diagnostics Yes; red LED Yes; red LED Yes; red LED Yes; red LED
Potential separation
Potential separation channels
● between the channels No No No Yes
● between the channels, in groups of 4 8 8 1
● between the channels and backplane bus Yes Yes Yes Yes
● between the channels and the power supply of the electronics Yes Yes Yes Yes
Permissible potential difference
between different circuits 60 V DC/30 V AC; insulation rated for 120 V AC basic insulation: between the channels and the supply voltage L+; between the channels and the backplane bus; between the channels
between the inputs (UCM) 20 V DC 20 V DC 20 V DC
Between the inputs and MANA (UCM) 10 V DC 10 V DC 10 V DC
Isolation
Isolation tested with 707 V DC (type test) 707 V DC (type test) 707 V DC (type test) 2 000 V DC between the channels and the supply voltage L+; 2 000 V DC between the channels and the backplane bus; 2 000 V DC between the channels; 707 V DC (type test) between the supply voltage L+ and the backplane bus
Standards, approvals, certificates
Suitable for applications according to AMS 2750 Yes; Declaration of Conformity, see online support entry 109757262
Suitable for applications according to CQI-9 Yes; Based on AMS 2750 E
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. -25 °C; From FS03 0 °C -25 °C; From FS02 -30 °C; From FS02
● horizontal installation, max. 60 °C 60 °C 60 °C 60 °C
● vertical installation, min. -25 °C; From FS03 0 °C -25 °C; From FS02 -30 °C; From FS02
● vertical installation, max. 40 °C 40 °C 40 °C 40 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Dimensions
Width 25 mm 35 mm 35 mm 35 mm
Height 147 mm 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm 129 mm
Weights
Weight, approx. 210 g 310 g 300 g 280 g
Other
Note: Supplied incl. 40-pole push-in front connectors. Additional basic error and noise for integration time = 2.5 ms: Voltage: ±250 mV (±0.02%), ±80 mV (±0.05%), ±50 mV (±0.05%); resistance: 150 Ohms (±0.02%); resistance thermometer: Pt100 climate: ±0.08 K, Ni100 climate: ±0.08 K; thermoelement: Type B, R, S: ±3 K, type E, J, K, N, T: ±1 K Additional basic error and noise for integration time = 2.5 ms: Voltage: ±250 mV (±0.02%), ±80 mV (±0.05%), ±50 mV (±0.05%); resistance: 150 ohms ±0.02%; resistance thermometer: Pt100 climate: ±0.08 K, Ni100 climate: ±0.08 K; thermocouple: Type B, R, S: ±3 K, type E, J, K, N, T: ±1 K

 

 

Article number 6ES7531-7PF00-0AB0
S7-1500, AI 8 X U/R/RTD/TC HF
General information
Product type designation AI 8xU/R/RTD/TC HF
HW functional status FS01
Firmware version V1.1.0
● FW update possible Yes
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode No
● Prioritized startup Yes
● Measuring range scalable Yes
● Scalable measured values No
● Adjustment of measuring range No
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V14 / –
● STEP 7 configurable/integrated from version V5.5 SP3 / –
● PROFIBUS from GSD version/GSD revision V1.0 / V5.1
● PROFINET from GSD version/GSD revision V2.3 / –
Operating mode
● Oversampling No
● MSI Yes
CiR – Configuration in RUN
Reparameterization possible in RUN Yes
Calibration possible in RUN Yes
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Input current
Current consumption, max. 55 mA; with 24 V DC supply
Power
Power available from the backplane bus 0.85 W
Power loss
Power loss, typ. 1.9 W
Analog inputs
Number of analog inputs 8; Plus one additional RTD (reference) channel
● For voltage measurement 8; Plus one additional RTD (reference) channel
● For resistance/resistance thermometer measurement 8; Plus one additional RTD (reference) channel
● For thermocouple measurement 8; Plus one additional RTD (reference) channel
permissible input voltage for voltage input (destruction limit), max. 20 V
Constant measurement current for resistance-type transmitter, typ. 150 Ohm, 300 Ohm, 600 Ohm, Cu10, Cu50, Cu100, Ni10, Ni100, Ni120, Ni200, Pt10, Pt50, Pt100, Pt200 climate: 1 mA; 6 kOhm, Ni500, Ni1000, LG-Ni1000, Pt200 standard, Pt500, Pt1000, PTC: 0.25 mA
Technical unit for temperature measurement adjustable Yes; °C/°F/K
Input ranges (rated values), voltages
● 0 to +5 V No
● 0 to +10 V No
● 1 V to 5 V No
● -1 V to +1 V Yes
— Input resistance (-1 V to +1 V) 10 MΩ
● -10 V to +10 V No
● -2.5 V to +2.5 V No
● -25 mV to +25 mV Yes
— Input resistance (-25 mV to +25 mV) 10 MΩ
● -250 mV to +250 mV Yes
— Input resistance (-250 mV to +250 mV) 10 MΩ
● -5 V to +5 V No
● -50 mV to +50 mV Yes
— Input resistance (-50 mV to +50 mV) 10 MΩ
● -500 mV to +500 mV Yes
— Input resistance (-500 mV to +500 mV) 10 MΩ
● -80 mV to +80 mV Yes
— Input resistance (-80 mV to +80 mV) 10 MΩ
Input ranges (rated values), currents
● 0 to 20 mA No
● -20 mA to +20 mA No
● 4 mA to 20 mA No
Input ranges (rated values), thermocouples
● Type B Yes
— Input resistance (Type B) 10 MΩ
● Type C Yes
— Input resistance (Type C) 10 MΩ
● Type E Yes
— Input resistance (Type E) 10 MΩ
● Type J Yes
— Input resistance (type J) 10 MΩ
● Type K Yes
— Input resistance (Type K) 10 MΩ
● Type L No
● Type N Yes
— Input resistance (Type N) 10 MΩ
● Type R Yes
— Input resistance (Type R) 10 MΩ
● Type S Yes
— Input resistance (Type S) 10 MΩ
● Type T Yes
— Input resistance (Type T) 10 MΩ
● Type TXK/TXK(L) to GOST Yes
— Input resistance (Type TXK/TXK(L) to GOST) 10 MΩ
Input ranges (rated values), resistance thermometer
● Cu 10 Yes; Standard/climate
— Input resistance (Cu 10) 10 MΩ
● Cu 10 according to GOST Yes; Standard/climate
— Input resistance (Cu 10 according to GOST) 10 MΩ
● Cu 50 Yes; Standard/climate
— Input resistance (Cu 50) 10 MΩ
● Cu 50 according to GOST Yes; Standard/climate
— Input resistance (Cu 50 according to GOST) 10 MΩ
● Cu 100 Yes; Standard/climate
— Input resistance (Cu 100) 10 MΩ
● Cu 100 according to GOST Yes; Standard/climate
— Input resistance (Cu 100 according to GOST) 10 MΩ
● Ni 10 Yes; Standard/climate
— Input resistance (Ni 10) 10 MΩ
● Ni 10 according to GOST Yes; Standard/climate
— Input resistance (Ni 10 according to GOST) 10 MΩ
● Ni 100 Yes; Standard/climate
— Input resistance (Ni 100) 10 MΩ
● Ni 100 according to GOST Yes; Standard/climate
— Input resistance (Ni 100 according to GOST) 10 MΩ
● Ni 1000 Yes; Standard/climate
— Input resistance (Ni 1000) 10 MΩ
● Ni 1000 according to GOST Yes; Standard/climate
— Input resistance (Ni 1000 according to GOST) 10 MΩ
● LG-Ni 1000 Yes; Standard/climate
— Input resistance (LG-Ni 1000) 10 MΩ
● Ni 120 Yes; Standard/climate
— Input resistance (Ni 120) 10 MΩ
● Ni 120 according to GOST Yes; Standard/climate
— Input resistance (Ni 120 according to GOST) 10 MΩ
● Ni 200 Yes; Standard/climate
— Input resistance (Ni 200) 10 MΩ
● Ni 200 according to GOST Yes; Standard/climate
— Input resistance (Ni 200 according to GOST) 10 MΩ
● Ni 500 Yes; Standard/climate
— Input resistance (Ni 500) 10 MΩ
● Ni 500 according to GOST Yes; Standard/climate
— Input resistance (Ni 500 according to GOST) 10 MΩ
● Pt 10 Yes; Standard/climate
— Input resistance (Pt 10) 10 MΩ
● Pt 10 according to GOST Yes; Standard/climate
— Input resistance (Pt 10 according to GOST) 10 MΩ
● Pt 50 Yes; Standard/climate
— Input resistance (Pt 50) 10 MΩ
● Pt 50 according to GOST Yes; Standard/climate
— Input resistance (Pt 50 according to GOST) 10 MΩ
● Pt 100 Yes; Standard/climate
— Input resistance (Pt 100) 10 MΩ
● Pt 100 according to GOST Yes; Standard/climate
— Input resistance (Pt 100 according to GOST) 10 MΩ
● Pt 1000 Yes; Standard/climate
— Input resistance (Pt 1000) 10 MΩ
● Pt 1000 according to GOST Yes; Standard/climate
— Input resistance (Pt 1000 according to GOST) 10 MΩ
● Pt 200 Yes; Standard/climate
— Input resistance (Pt 200) 10 MΩ
● Pt 200 according to GOST Yes; Standard/climate
— Input resistance (Pt 200 according to GOST) 10 MΩ
● Pt 500 Yes; Standard/climate
— Input resistance (Pt 500) 10 MΩ
● Pt 500 according to GOST Yes; Standard/climate
— Input resistance (Pt 500 according to GOST) 10 MΩ
Input ranges (rated values), resistors
● 0 to 150 ohms Yes
— Input resistance (0 to 150 ohms) 10 MΩ
● 0 to 300 ohms Yes
— Input resistance (0 to 300 ohms) 10 MΩ
● 0 to 600 ohms Yes
— Input resistance (0 to 600 ohms) 10 MΩ
● 0 to 3000 ohms No
● 0 to 6000 ohms Yes
— Input resistance (0 to 6000 ohms) 10 MΩ
● PTC Yes
— Input resistance (PTC) 10 MΩ
Thermocouple (TC)
Temperature compensation
— parameterizable Yes
— internal temperature compensation Yes
— external temperature compensation via RTD Yes
— Compensation for 0 °C reference point temperature Yes; fixed value can be set
— Reference channel of the module Yes; 9th channel that can be used as a genuine 9th RTD channel regardless of the parameterization of the other channels, or that can be used for compensation in the case of TC measurement
Cable length
● shielded, max. 800 m; at U; 200 m at R/RTD/TC
Analog value generation for the inputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 21 bit; For measuring mode RTC and TC when using the function “Scalable temperature measuring range” (32 bit REAL format); 16 bit for measuring mode R and U; 16 bit for all measuring modes when using the S7 format (16 bit INTEGER)
● Integration time, parameterizable Yes
● Integration time (ms) Fast mode: 2.5 / 16.67 / 20 / 100 ms, standard mode: 7.5 / 50 / 60 / 300 ms
● Basic conversion time, including integration time (ms) Fast mode: 4 / 18 / 22 / 102 ms; Standard mode: 9 / 52 / 62 / 302 ms
— additional conversion time for wire-break monitoring Thermocouples, 150 Ohm, 300 Ohm, 600 Ohm, Cu10, Cu50, Cu100, Ni10, Ni100, Ni120, Ni200, Pt10, Pt50, Pt100: 4 ms; 6 kOhm, Ni500, Ni1000, LG-Ni1000, Pt200, Pt500, Pt1000: 13 ms
● Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 / 10 Hz
● Basic execution time of the module (all channels released) Corresponds to the channel with the highest basic conversion time
Smoothing of measured values
● parameterizable Yes
● Step: None Yes
● Step: low Yes
● Step: Medium Yes
● Step: High Yes
Encoder
Connection of signal encoders
● for voltage measurement Yes
● for current measurement as 2-wire transducer No
● for current measurement as 4-wire transducer No
● for resistance measurement with two-wire connection Yes
● for resistance measurement with three-wire connection Yes; All measuring ranges except PTC; internal compensation of the cable resistances
● for resistance measurement with four-wire connection Yes; All measuring ranges except PTC
Errors/accuracies
Linearity error (relative to input range), (+/-) 0.02 %
Temperature error (relative to input range), (+/-) 0.005 %/K
Crosstalk between the inputs, max. -80 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) 0.02 %
Temperature error of internal compensation ±1,5 °C
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-) 0.1 %
● Resistance, relative to input range, (+/-) 0.1 %
● Resistance thermometer, relative to input range, (+/-) Cuxxx Standard: ±0.5 K, Cuxxx Klima: ±0.5 K, Ptxxx Standard: ±1 K, Ptxxx Klima: ±0.5 K, Nixxx Standard: ±0.5 K, Nixxx Klima: ±0.3 K
● Thermocouple, relative to input range, (+/-) Type B: > 600 °C ±2 K, Type E: > -200 °C ±1 K, Type J: > -210 °C ±1 K, Type K: > -200 °C ±2 K, Type N: > -200 °C ±2 K, Type R: > 0 °C ±2 K, Type S: > 0 °C ±2 K, Type T: > -200 °C ±1 K, Type C: ±4 K, Type TXK/TXK(L): ±1 K
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-) 0.05 %
● Resistance, relative to input range, (+/-) 0.05 %
● Resistance thermometer, relative to input range, (+/-) Cuxxx Standard: ±0.3 K, Cuxxx Klima: ±0.2 K, Ptxxx Standard: ±0.5 K, Ptxxx Klima: ±0.2 K, Nixxx Standard: ±0.3 K, Nixxx Klima: ±0.15 K
● Thermocouple, relative to input range, (+/-) Type B: > 600 °C ±1 K, Type E: > -200 °C ±0.5 K, Type J: > -210 °C ±0.5 K, Type K: > -200 °C ±1 K, Type N: > -200 °C ±1 K, Type R: > 0 °C ±1 K, Type S: > 0 °C ±1 K, Type T: > -200 °C ±0.5 K, Type C: ±2 K, Type TXK/TXK(L): ±0.5 K
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of interference < rated value of input range), min. 80 dB; in the Standard operating mode, 40 dB in the Fast operating mode
● Common mode voltage, max. 60 V DC/30 V AC
● Common mode interference, min. 80 dB
Interrupts/diagnostics/status information
Diagnostics function Yes
Alarms
● Diagnostic alarm Yes
● Limit value alarm Yes; two upper and two lower limit values in each case
Diagnoses
● Monitoring the supply voltage Yes
● Wire-break Yes; Only with TC, R, RTD
● Overflow/underflow Yes
Diagnostics indication LED
● RUN LED Yes; green LED
● ERROR LED Yes; red LED
● Monitoring of the supply voltage (PWR-LED) Yes; green LED
● Channel status display Yes; green LED
● for channel diagnostics Yes; red LED
● for module diagnostics Yes; red LED
Potential separation
Potential separation channels
● between the channels Yes
● between the channels, in groups of 1
● between the channels and backplane bus Yes
● between the channels and the power supply of the electronics Yes
Permissible potential difference
between different circuits 60 V DC/30 V AC; insulation rated for 120 V AC basic insulation: between the channels and the supply voltage L+; between the channels and the backplane bus; between the channels
Isolation
Isolation tested with 2 000 V DC between the channels and the supply voltage L+; 2 000 V DC between the channels and the backplane bus; 2 000 V DC between the channels; 707 V DC (type test) between the supply voltage L+ and the backplane bus
Standards, approvals, certificates
Suitable for applications according to AMS 2750 Yes; Declaration of Conformity, see online support entry 109757262
Suitable for applications according to CQI-9 Yes; Based on AMS 2750 E
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. 0 °C
● horizontal installation, max. 60 °C
● vertical installation, min. 0 °C
● vertical installation, max. 40 °C
Dimensions
Width 35 mm
Height 147 mm
Depth 129 mm
Weights
Weight, approx. 290 g
Other
Note: for the R/RDT three-wire measurement, the conductor compensation is made alternating with the measurement; this then requires two module cycles for a measured value
Weight N/A
Dimensions N/A