SIMATIC IM155-6MF High Feature, MultiFieldbus IM with two slots for SIMATIC BusAdapters

Differences compared to the 2-port IM155-6PN/2 High Feature:

  • Multi-protocol capability
    Operation on Ethernet controllers via the PROFINET, EtherNet/IP and Modbus protocols
  • Compatible with IM155-6MF High Feature (as of 6ES7155-6AU01-0CN0);
    Exception: Isochronous mode and prioritized startup
  • Shared device:
    Simultaneous access from different controllers via different Ethernet protocols PROFINET, EtherNet/IP and Modbus TCP
  • Local data links:
    Deterministic, easy-to-configure data exchange between controllers, also via different Ethernet protocols PROFINET, EtherNet/IP and Modbus TCP

Siemens Interface Modules ET 200SP Product Specifications:

Article number 6ES7155-6MU00-0CN0
ET 200SP, IM155-6MF HF
General information
Product type designation IM 155-6 MF HF
Firmware version V5.1.1
● FW update possible Yes
Vendor identification (VendorID) 002AH
Device identifier (DeviceID) 0313H
Manufacturer ID according to ODVA (VendorID) 04E3H
Device ID according to ODVA (Product code) 0FA2H
Product function
● I&M data Yes; I&M0 to I&M3
● Module swapping during operation (hot swapping) Yes; Multi-hot swapping
● Isochronous mode No
● Tool changer Yes; Docking station and docking unit
● Local coupling, IO data No
● Local coupling, data records No
Engineering with
● STEP 7 TIA Portal configurable/integrated from version via IM155-6PN/2 HF in compatibility mode
● STEP 7 configurable/integrated from version via IM155-6PN/2 HF in compatibility mode
● PROFINET from GSD version/GSD revision GSDML V2.3
● Multi Fieldbus Configuration Tool (MFCT) V1.0 Update 2
Configuration control
via dataset Yes
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
● Mains/voltage failure stored energy time 10 ms; according to IEC 61131-2 (6.2.1.3) severity degree PS2
Input current
Current consumption, max. 700 mA
Inrush current, max. 4.5 A
I²t 0.25 A²·s
Power loss
Power loss, typ. 2.4 W
Address area
Address space per module
● Address space per module, max. 288 byte; For input and output data respectively
Address space per station
● Address space per station, max. 1 440 byte; Dependent on configuration
Hardware configuration
Rack
● Quantity of operable ET 200SP modules, max. 64
● Quantity of operable ET 200AL modules, max. 16
Submodules
● Number of submodules per station, max. 256
Time stamping
Accuracy 10 ms
Interfaces
Number of PROFINET interfaces 1; 2 ports (switch)
1. Interface
Interface types
● Number of ports 2; via BusAdapter
● integrated switch Yes
● BusAdapter (PROFINET) Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC,
Protocols
● PROFINET IO Device Yes
● Open IE communication Yes
● Media redundancy Yes; PROFINET MRP
Interface types
RJ 45 (Ethernet)
● Transmission procedure PROFINET with 100 Mbit/s full duplex (100BASE-TX)
● 10 Mbps No
● 100 Mbps Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)
● Autonegotiation Yes
● Autocrossing Yes
Protocols
Modbus TCP Yes
Number of connections
● Number of MtM communication relationships/connections, max. 16
PROFINET IO Device
Services
— IRT No
— PROFIenergy Yes
— Prioritized startup No
— Shared device No
Redundancy mode
● PROFINET system redundancy (S2) Yes; NAP S2
● H-Sync forwarding Yes
Media redundancy
— MRP Yes
— MRPD No
EtherNet/IP
Services
— CIP Implicit Messaging Yes
— CIP Explicit Messaging Yes
— CIP Safety No
— Configuration control via Explicit Messaging No
— Shared device No
Updating times
— Requested Packet Interval (RPI) 2 ms
Address area
— Address space per module, max. 288 byte; (246 byte outputs / 288 byte inputs)
— ForwardOpen (Class1 & 32 bit Header) 500 byte; (246 byte outputs / 500 byte inputs)
— LargeForwardOpen (Class3) 4 002 byte
Connections
— Number of rack connections 1
Modbus TCP
Services
— Read Holding Registers (Code=3) Yes
— Write Multiple Registers (Code=16) Yes
— Parameter change by master Yes
— Modbus TCP Security Protocol No
Address space per station
— Address space per station, max. 500 byte; (246 byte outputs / 500 byte inputs)
— Access-consistent address space 250 byte; (246 byte outputs / 250 byte inputs)
Updating time
— I/O request interval 2 ms
Connections
— Number of connections per slave 9; (1x inputs / 2x outputs / 4x volatile registers / 2x Device Info)
Open IE communication
● TCP/IP Yes
● UDP Yes
● SNMP Yes
● LLDP Yes
● ARP Yes
● IGMP Yes
● Multicast Yes
● Broadcast Yes
● IPv4 Yes
Interrupts/diagnostics/status information
Status indicator Yes
Alarms Yes
Diagnostics function Yes
Diagnostics indication LED
● RUN LED Yes; green LED
● ERROR LED Yes; red LED
● MAINT LED Yes; Yellow LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED
● NS LED Yes; green/red LED
● MS LED Yes; green/red LED
● IO LED Yes; red-green-yellow LED
● Connection display LINK TX/RX Yes; 2x green link LEDs on BusAdapter
Potential separation
between backplane bus and electronics No
between PROFINET and all other circuits Yes
between supply and all other circuits No
Isolation
Isolation tested with 707 V DC (type test)
Standards, approvals, certificates
Network loading class 3
Security level According to Security Level 1 Test Cases V1.1.1
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. -30 °C; No condensation
● horizontal installation, max. 60 °C
● vertical installation, min. -30 °C; No condensation
● vertical installation, max. 50 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
connection method / header
ET-Connection
● via BU/BA Send Yes; + 16 ET 200AL modules
Mechanics/material
Strain relief Yes; Optional
Dimensions
Width 50 mm
Height 117 mm
Depth 74 mm
Weights
Weight, approx. 120 g; without BusAdapter
Weight N/A
Dimensions N/A