CM PtP communications module for serial communication connections with RS232 and RS422 interfaces. RS485 for the Freeport, 3964(R), Modbus RTU, USS and DMX512 protocols, max. 115.2250 kbps, 2 KB frame length, 4 KB receive buffer.

Siemens Communication Modules ET 200SP Product Specifications:

Article number 6ES7137-6AA01-0BA0
ET 200SP, CM PTP, PU 1
General information
Product type designation CM PtP
Firmware version
● FW update possible Yes
usable BaseUnits BU type A0
Product function
● I&M data Yes; I&M0 to I&M3
Engineering with
● STEP 7 TIA Portal configurable/integrated from version STEP 7 V17 or higher
● STEP 7 configurable/integrated from version via GSD as of V5.6 HF4
● PROFIBUS from GSD version/GSD revision GSD as of Revision 5
● PROFINET from GSD version/GSD revision GSDML V2.34
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Input current
Current consumption (rated value) 31 mA
Current consumption, max. 35 mA
Power loss
Power loss, typ. 0.7 W
Address area
Address space per module
● Inputs 8 byte; performance mode: 32 byte
● Outputs 0 byte; performance mode: 32 byte
1. Interface
Interface types
● RS 485 Yes
● RS 422 Yes
● RS 232 Yes
● Design of the connection Push-in terminal
Interface types
RS 232
● Transmission rate, max. 115.2 kbit/s
● Cable length, max. 15 m
● RS 232 auxiliary signals RTS, CTS, DTR, DSR, RI, DCD
RS 485
● Transmission rate, max. 250 kbit/s
● Cable length, max. 1 200 m; 100 to 1200 m, depending on transmission speed
RS 422
● Transmission rate, max. 115.2 kbit/s
● Cable length, max. 1 200 m
● 4-wire full duplex connection Yes
● 4-wire multipoint connection Yes
Protocols
Integrated protocols
Freeport
— Telegram length, max. 2 kbyte; performance mode: receive data max. 24 byte and send data max. 30 byte
— Bits per character 7 or 8
— Number of stop bits 1 or 2 bit
— Parity None, even, odd, always 1, always 0, any
3964 (R)
— Telegram length, max. 2 kbyte; performance mode: receive data max. 24 byte and send data max. 30 byte
— Bits per character 7 or 8
— Number of stop bits 1 or 2 bit
— Parity None, even, odd, always 1, always 0, any
Modbus RTU master
— Address area 1 to 247, extended 1 to 65535
— Number of slaves, max. 32
MODBUS RTU slave
— Address area 1 to 247, extended 1 to 65535
Telegram buffer
● Buffer memory for telegrams 4 kbyte
● Number of telegrams which can be buffered 255
Interrupts/diagnostics/status information
Diagnostics function Yes
Alarms
● Diagnostic alarm Yes
● Hardware interrupt No
Diagnoses
● Wire-break Yes
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED
● for module diagnostics Yes; green/red DIAG LED
● Receive RxD Yes; green LED
● Transmit TxD Yes; green LED
Potential separation
between backplane bus and interface Yes
Isolation
Isolation tested with 707 V DC (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. -30 °C
● horizontal installation, max. 60 °C
● vertical installation, min. -30 °C
● vertical installation, max. 50 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m
Decentralized operation
to SIMATIC S7-300 Yes
to SIMATIC S7-400 Yes
to SIMATIC S7-1200 Yes
to SIMATIC S7-1500 Yes
to standard PROFINET controller Yes
Dimensions
Width 15 mm
Height 73 mm
Depth 58 mm
Weights
Weight, approx. 30 g
Weight N/A