Contact Us:
sales@inosaki.com

SIMATIC ET 200SP – BU Type A0 – Siemens Base Units

$ 32.43$ 46.46

SKU N/A Category

With the BaseUnits (BUs), the ET 200SP offers a rugged and service-friendly design with permanent wiring:

  • No tools needed for one-handed wiring using push-in terminals
  • Actuation of the spring NC contacts with a standard screwdriver, with a blade width up to 3.5 mm
  • Outstanding access due to arrangement of measuring tap, spring NC contacts and cable entry in columns, while at the same time reducing the space required by 64%
  • Fault-proof color coding of the spring NC contacts for better orientation in the terminal panel
  • Replacement of I/O modules during operation without affecting the wiring
  • Operation with module gaps (gaps without I/O module)
  • Automatic coding of the I/O modules prevents destruction of the electronics if a module is accidentally inserted in the wrong slot during replacement
  • High EMC interference immunity:
    • self-assembling shielded backplane bus
    • multi-layer conductor plate with shield levels for interference-free signal transmission from the terminal to the I/O module
    • system-integrated, space-saving shield connection for quick installation
  • Self-assembling potential groups without external wiring or jumpers
  • Replaceable terminal box
  • Side-by-side latching of the BUs for high mechanical and EMC loads
  • Optional module-specific color identification of the terminals according to the color code CC
  • Optional equipment marking using slide-in equipment labeling plates

An ET 200SP station can be expanded via one ‘BU-Send’ BaseUnit with a “BA-Send” BusAdapter plugged onto it with up to 16 modules from the ET 200AL series of I/O devices with IP67 protection.

Siemens BaseUnit ET 200SP Product Specifications:

Article number 6ES7193-6BP20-0DA0 6ES7193-6BP00-0DA0 6ES7193-6BP20-0BA0 6ES7193-6BP00-0BA0
BaseUnit Type A0, BU15-P16+A10+2D BaseUnit Type A0, BU15-P16+A0+2D BaseUnit Type A0, BU15-P16+A10+2B BaseUnit Type A0, BU15-P16+A0+2B
General information
Product type designation BU type A0 BU type A0 BU type A0 BU type A0
HW functional status From FS07 From FS06 From FS06 From FS06
Supply voltage
Rated value (DC) 24 V 24 V 24 V 24 V
external protection for power supply lines Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic
Mains filter
● integrated Yes No
Current carrying capacity
For P1 and P2 bus, max. 10 A 10 A 10 A 10 A
For AUX bus, max. 10 A 10 A
For process terminals, max. 2 A 2 A 2 A 2 A
Hardware configuration
Automatic encoding Yes
Formation of potential groups
● New potential group Yes Yes No No
● Potential group continued from the left No No Yes Yes
Slots
● Number of slots 1; Type A0 1; Type A0 1; Type A0 1; Type A0
Potential separation
between the potential groups Yes Yes
Isolation
Isolation tested with 707 V DC (type test) 707 V DC (type test) 707 V DC (type test) 707 V DC (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. -30 °C -30 °C -30 °C -30 °C
● horizontal installation, max. 60 °C 60 °C 60 °C 60 °C
● vertical installation, min. -30 °C -30 °C -30 °C -30 °C
● vertical installation, max. 50 °C 50 °C 50 °C 50 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Accessories
Color coding labels
● for process terminals CC00 to CC09 CC00 to CC09 CC00 to CC09 CC00 to CC09
● for AUX terminals CC71 to CC73 does not exist CC71 to CC73 does not exist
● for add-on terminals does not exist does not exist does not exist does not exist
connection method / header
Terminals
● Terminal type Push-in terminal Push-in terminal Push-in terminal Push-in terminal
● Conductor cross-section, min. 0.14 mm²; AWG 26 0.14 mm²; AWG 26 0.14 mm²; AWG 26 0.14 mm²; AWG 26
● Conductor cross-section, max. 2.5 mm²; AWG 14 2.5 mm²; AWG 14 2.5 mm²; AWG 14 2.5 mm²; AWG 14
● Number of process terminals to I/O module 16 16 16 16; Pro slot
● Number of terminals to AUX bus 10 0 10 0
● Number of add-on terminals 0 0 0 0
● Number of terminals with connection to P1 and P2 bus 2 2 2 2; Pro slot
Dimensions
Width 15 mm 15 mm 15 mm 15 mm
Height 141 mm 117 mm 141 mm 117 mm
Depth 35 mm 35 mm 35 mm 35 mm
Weights
Weight, approx. 50 g 40 g 50 g 40 g

Additional information

Weight N/A
Dimensions N/A
Model

BU15-P16+A0+2B, BU15-P16+A0+2D, BU15-P16+A10+2B, BU15-P16+A10+2D

Related Products

SIMATIC ET 200SP_BA 2xFC
SICK_Safety_controllers_6026136
BX15M-TDT
Computar_Telecentric Lens_TEC-M55
1605167428
SIEMENS_SIMATIC-ET 200pro_Interface_Modules_IM 154-4 PN_6ES7154-4AB10-0AB0
Select your currency