SIMATIC ET 200AL – PROFINET Interface Module IM 157-1 PN – Siemens Interface Modules

 260.80

SKU: 6ES7157-1AB00-0AB0

The IM 157-1 PN interface module enables the connection of ET 200AL to PROFINET and handles the communication between the I/O modules and the higher-level PROFINET I/O controller in the PLC autonomously.

Siemens Interface Modules ET 200AL Product Specifications:

Article number 6ES7157-1AB00-0AB0
ET 200AL, IM 157-1 PN
General information
Product type designation IM 157-1 PN
HW functional status FS02
Firmware version V1.0.x
Vendor identification (VendorID) 002AH
Product function
● I&M data Yes; I&M0 to I&M4
Engineering with
● STEP 7 TIA Portal configurable/integrated from version STEP 7 V13 SP1 or higher
● STEP 7 configurable/integrated from version From V5.5 SP4 Hotfix 3
● PROFINET from GSD version/GSD revision GSDML V2.3.1
Configuration control
via dataset Yes
Supply voltage
power supply according to NEC Class 2 required No
Load voltage 1L+
● Rated value (DC) 24 V
● permissible range, lower limit (DC) 20.4 V
● permissible range, upper limit (DC) 28.8 V
● Reverse polarity protection Yes; against destruction
Input current
Current consumption (rated value) 100 mA
from load voltage 1L+ (unswitched voltage) 4 A; Maximum value
from load voltage 2L+, max. 4 A; Maximum value
Power loss
Power loss, typ. 2.9 W
Address area
Address space per station
● Address space per station, max. 1 430 byte
Interfaces
Number of PROFINET interfaces 1
1. Interface
Interface type PROFINET
Interface types
● M12 port Yes; 2x M12 D-coded
● integrated switch Yes
Protocols
● PROFINET IO Device Yes
● Open IE communication Yes
Interface types
M12 port
● Transmission procedure PROFINET with 100 Mbit/s full duplex (100BASE-TX)
● 10 Mbps Yes; for Ethernet services
● 100 Mbps Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)
● Autonegotiation Yes
● Autocrossing Yes
Protocols
PROFINET IO Device
Services
— IRT Yes; 250 µs, 500 µs, 1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms, 64 ms, 128 ms
— PROFIenergy Yes
— Shared device Yes
— Number of IO Controllers with shared device, max. 4
Redundancy mode
Media redundancy
— MRP Yes
— MRPD Yes
Open IE communication
● TCP/IP Yes
● SNMP Yes
● LLDP Yes
Interrupts/diagnostics/status information
Diagnostics function Yes
Alarms
● Diagnostic alarm Yes
Diagnostics indication LED
● RUN LED Yes; green LED
● ERROR LED Yes; red LED
● MAINT LED Yes; Yellow LED
● Connection display LINK TX/RX Yes; 2x green LED
Potential separation
between the load voltages Yes
between PROFINET and all other circuits Yes
Isolation
Isolation tested with 707 V DC (type test)
Degree and class of protection
IP degree of protection IP65/67
Standards, approvals, certificates
Suitable for safety-related tripping of standard modules Yes; From FS01
Highest safety class achievable for safety-related tripping of standard modules
● Performance level according to ISO 13849-1 PL d
● Category according to ISO 13849-1 Cat. 3
● SIL acc. to IEC 62061 SIL 2
Ambient conditions
Ambient temperature during operation
● min. -25 °C
● max. 55 °C
connection method / header
Design of electrical connection for supply voltage M8, 4-pole
ET-Connection
● ET-Connection M8, 4-pin, shielded
Dimensions
Width 45 mm
Height 159 mm
Depth 40 mm
Weights
Weight, approx. 263 g
Weight 0.3 kg
Dimensions 5.5 × 17.6 × 5.2 cm