General information | |
Article number | 6ES7134-6PA01-0BD0 |
Product type designation | AI energy meter 400VAC ST |
Firmware version | V3.0 |
usable BaseUnits | BU type D0 |
Product function | |
● Voltage measurement | Yes |
— with voltage transformer | No |
● Current measurement | Yes |
— without current transformer | No |
— with current transformer | Yes |
● Energy measurement | Yes |
● Frequency measurement | Yes |
● Power measurement | Yes |
● Active power measurement | Yes |
● Reactive power measurement | Yes |
● I&M data | Yes; I&M0 to I&M3 |
● Isochronous mode | No |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from version | V13 SP1 |
● STEP 7 configurable/integrated from version | V5.5 SP4 and higher |
● PROFIBUS from GSD version/GSD revision | GSD Revision 5 |
● PROFINET from GSD version/GSD revision | V2.3 |
Operating mode | |
● cyclic measurement | Yes |
● acyclic measurement | Yes |
● Acyclic measured value access | Yes |
● Fixed measured value sets | Yes |
● Freely definable measured value sets | No |
CiR – Configuration in RUN | |
Reparameterization possible in RUN | Yes |
Calibration possible in RUN | No |
Installation type/mounting | |
Mounting position | any |
Supply voltage | |
Design of the power supply | Supply via voltage measurement channel L1 |
Rated value (AC) | 100 – 240 V AC |
permissible range, lower limit (AC) | 90 V |
permissible range, upper limit (AC) | 264 V |
Line frequency | |
● permissible range, lower limit | 47 Hz |
● permissible range, upper limit | 63 Hz |
Power loss | |
Power loss, typ. | 0.6 W |
Address area | |
Address space per module | |
● Address space per module, max. | 44 byte; 32 byte input / 12 byte output |
Hardware configuration | |
Automatic encoding | |
● Mechanical coding element | Yes |
● Type of mechanical coding element | type C |
Time of day | |
Operating hours counter | |
● present | No |
Analog inputs | |
Cycle time (all channels), typ. | 50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data) |
Interrupts/diagnostics/status information | |
Alarms | |
● Diagnostic alarm | Yes |
● Limit value alarm | No |
● Hardware interrupt | No |
Diagnostics indication LED | |
● Monitoring of the supply voltage (PWR-LED) | Yes |
● Channel status display | Yes; green LED |
● for channel diagnostics | Yes; red Fn LED |
● for module diagnostics | Yes; green/red DIAG LED |
Integrated Functions | |
Measuring functions | |
● Measuring procedure for voltage measurement | TRMS |
● Measuring procedure for current measurement | TRMS |
● Type of measured value acquisition | seamless |
● Curve shape of voltage | Sinusoidal or distorted |
● Buffering of measured variables | No |
● Parameter length | 38 byte |
● Bandwidth of measured value acquisition | 2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz |
Measuring range | |
— Frequency measurement, min. | 45 Hz |
— Frequency measurement, max. | 65 Hz |
Measuring inputs for voltage | |
— Measurable line voltage between phase and neutral conductor | 230 V |
— Measurable line voltage between the line conductors | |
— Measurable line voltage between phase and neutral conductor, min. | 400 V |
— Measurable line voltage between phase and neutral conductor, max. | 90 V |
— Measurable line voltage between the line conductors, min. | 264 V |
— Measurable line voltage between the line conductors, max. | 155 V |
— Internal resistance line conductor and neutral conductor | 460 V |
— Power consumption per phase | 3.4 MΩ |
— Impulse voltage resistance 1,2/50µs | 20 mW |
— Measurement category for voltage | 1 kV |
measurement in accordance with IEC 61010-2030 | CAT II; CAT III in case of guaranteed protection level of 1.5 kV |
Measuring inputs for current | |
— measurable relative current (AC), min. | 5 %; Relative to the secondary rated current; 1 A, 5 A |
— measurable relative current (AC), max. | 100 %; Relative to the secondary rated current; 1 A, 5 A |
— Continuous current with AC, maximum permissible | 5:00 AM |
— Apparent power consumption per phase for measuring range 5 A | 0.6 VA |
— Rated value short-time withstand current restricted to 1 s | 100 A |
— Input resistance measuring range 0 to 5 A | 25 mΩ; At the terminal |
— Surge strength | 10 A; for 1 minute |
— Zero point suppression | Parameterizable: 20 … 250 mA, default 50 mA |
Accuracy class according to IEC 61557-12 | |
— Measured variable voltage | 0.5 |
— Measured variable current | 0.5 |
— Measured variable apparent power | 1 |
— Measured variable active power | 1 |
— Measured variable reactive power | 1 |
— Measured variable power factor | 0.5 |
— Measured variable active energy | 1 |
— Measured variable reactive energy | 2 |
— Measured variable phase angle | ±1 °; not covered by IEC 61557-12 |
— Measured variable frequency | 0.05 |
Potential separation | |
Potential separation channels | |
● between the channels and backplane bus | Yes; 3 700V AC (type test) CAT III |
Isolation | |
Isolation tested with | 2 300V AC for 1 min. (type test) |
Ambient conditions | |
Ambient temperature during operation | |
● horizontal installation, min. | 0 °C |
● horizontal installation, max. | 60 °C |
● vertical installation, min. | 0 °C |
● vertical installation, max. | 50 °C |
Dimensions | |
Width | 20 mm |
Height | 73 mm |
Depth | 58 mm |
Weights | |
Weight, approx. | 45 g |
Other | |
Data for selecting a current transformer | |
● Burden power current transformer x/1A, min. ● Burden power current transformer x/5A, min. | As a function of cable length and cross section, see device manual |
As a function of cable length and cross section, see device manual |
General information | |
Article number | 6ES7134-6PA20-0BD0 |
Product type designation | AI Energy Meter 480VAC ST |
Firmware version | V4.0 |
● FW update possible | Yes |
usable BaseUnits | BU type D0 |
Supported power supply systems | TT, TN |
Product function | |
● Voltage measurement | Yes |
— without voltage transformer | Yes |
— with voltage transformer | Yes |
● Current measurement | Yes |
— without current transformer | No |
— with current transformer | Yes |
— With Rogowski coil | No |
— With current-voltage-converter | No |
● Energy measurement | Yes |
● Frequency measurement | Yes |
● Power measurement | Yes |
● Active power measurement | Yes |
● Reactive power measurement | Yes |
● Power factor measurement | Yes |
● Active factor measurement | No |
● Reactive power compensation | No |
● Line analysis | No |
● I&M data | Yes; I&M0 to I&M3 |
● Isochronous mode | No |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from version | V13 SP1 |
● STEP 7 configurable/integrated from version | V5.5 SP4 and higher |
● PROFIBUS from GSD version/GSD revision | GSD Revision 5 |
● PROFINET from GSD version/GSD revision | V2.3 |
Operating mode | |
● Cyclic measured value access | Yes |
● Acyclic measured value access | Yes |
● Fixed measured value sets | Yes |
● Freely definable measured value sets | Yes |
CiR – Configuration in RUN | |
Reparameterization possible in RUN | Yes |
Calibration possible in RUN | Yes |
Installation type/mounting | |
Mounting position | any |
Supply voltage | |
Design of the power supply | Supply via voltage measurement channel L1 |
Rated value (AC) | AC 100 – 277 V |
permissible range, lower limit (AC) | 90 V |
permissible range, upper limit (AC) | 293 V |
Line frequency | |
● permissible range, lower limit | 47 Hz |
● permissible range, upper limit | 63 Hz |
Power loss | |
Power loss, typ. | 0.6 W |
Address area | |
Address space per module | |
● Inputs | 256 byte |
● Outputs | 12 byte |
Hardware configuration | |
Automatic encoding | Yes |
● Mechanical coding element | Yes |
● Type of mechanical coding element | type C |
Selection of BaseUnit for connection variants | |
● 2-wire connection | BU type D0, BU20-P12+A0+0B |
Time of day | |
Operating hours counter | |
● present | Yes |
Analog inputs | |
Cycle time (all channels), typ. | 50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data) |
Cable length | |
● unshielded, max. | 200 m |
Analog value generation for the inputs | |
Measurement principle | Sigma Delta |
Sampling frequency, max. | 1 024 kHz |
Interrupts/diagnostics/status information | |
Alarms | |
● Diagnostic alarm | Yes |
● Limit value alarm | Yes |
● Hardware interrupt | Yes; Monitoring of up to 16 freely selectable process values (exceeding or undershooting of value) |
Diagnostics indication LED | |
● Monitoring of the supply voltage (PWR-LED) | Yes |
● Channel status display | Yes; green LED |
● for channel diagnostics | Yes; red Fn LED |
● for module diagnostics | Yes; green/red DIAG LED |
Integrated Functions | |
Measuring functions | |
● Measuring procedure for voltage measurement | TRMS |
● Measuring procedure for current measurement | TRMS |
● Type of measured value acquisition | seamless |
● Curve shape of voltage | Sinusoidal or distorted |
● Buffering of measured variables | Yes |
● Parameter length | 74 byte |
● Bandwidth of measured value acquisition | 2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz |
Measuring range | |
— Frequency measurement, min. | 45 Hz |
— Frequency measurement, max. | 65 Hz |
Measuring inputs for voltage | |
— Measurable line voltage between phase and neutral conductor | 277 V |
— Measurable line voltage between the line conductors | 480 V |
— Measurable line voltage between phase and neutral conductor, min. | |
— Measurable line voltage between phase and neutral conductor, max. | 90 V |
— Measurable line voltage between the line conductors, min. | 293 V |
— Measurable line voltage between the line conductors, max. | 155 V |
— Internal resistance line conductor and neutral conductor | 508 V |
— Power consumption per phase | 3.4 MΩ |
— Impulse voltage resistance 1,2/50µs | 20 mW |
— Measurement category for voltage | 1 kV |
measurement in accordance with IEC 61010-2030 | CAT II; CAT III in case of guaranteed protection level of 1.5 kV |
Measuring inputs for current | |
— measurable relative current (AC), min. | 1 %; Relative to the secondary rated current 5 A |
— measurable relative current (AC), max. | 100 %; Relative to the secondary rated current 5 A |
— Continuous current with AC, maximum permissible | 5:00 AM |
— Apparent power consumption per phase for measuring range 5 A | 0.6 VA |
— Rated value short-time withstand current restricted to 1 s | 100 A |
— Input resistance measuring range 0 to 5 A | 25 mΩ; At the terminal |
— Surge strength | 10 A; for 1 minute |
— Zero point suppression | Parameterizable: 2 … 250 mA, default 50 mA |
Accuracy class according to IEC 61557-12 | |
— Measured variable voltage | 0,2 |
— Measured variable current | 0,2 |
— Measured variable apparent power | 0.5 |
— Measured variable active power | 0.5 |
— Measured variable reactive power | 1 |
— Measured variable power factor | 0.5 |
— Measured variable active energy | 0.5 |
— Measured variable reactive energy | 1 |
— Measured variable neutral current | 0.5; calculated |
— Measured variable phase angle | ±1 °; not covered by IEC 61557-12 |
— Measured variable frequency | 0.05 |
Potential separation | |
Potential separation channels | |
● between the channels | No |
● between the channels and backplane bus | Yes; 3 700V AC (type test) CAT III |
Isolation | |
Isolation tested with | 2 300V AC for 1 min. (type test) |
Ambient conditions | |
Ambient temperature during operation | |
● horizontal installation, min. | 0 °C |
● horizontal installation, max. | 60 °C |
● vertical installation, min. | 0 °C |
● vertical installation, max. | 50 °C |
Altitude during operation relating to sea level | |
● Ambient air temperature-barometric pressurealtitude | On request: Ambient temperatures lower than 0 °C (without condensation) and/or installation altitudes greater than 2 000 m |
Dimensions | |
Width | 20 mm |
Height | 73 mm |
Depth | 58 mm |
Weights | |
Weight, approx. | 45 g |
Other | |
Data for selecting a voltage transformer | |
● Secondary side, max. | 296 V |
Data for selecting a current transformer | |
● Burden power current transformer x/1A, min. ● Burden power current transformer x/5A, min. | As a function of cable length and cross section, see device manual |
As a function of cable length and cross section, see device manual |
Weight | N/A |
---|---|
Dimensions | N/A |