Schneider Electric GV2L07 Motor Circuit Breaker

USD 89.55

Compact 3P magnetic motor circuit breaker with 2.5A rating, 100kA breaking capacity at 400V, and rotary handle. Provides short-circuit protection up to 0.75kW.

SKU Schneider-GV2L07 Category
Top Brands > Schneider Electric > Schneider Circuit Breakers

Schneider Electric GV2L07 Motor Circuit Breaker

Model Identifier GV2L07
Official Part Number GV2L07
GTIN Standard 3389110213249

Technical Overview

Compact 3P magnetic motor circuit breaker with 2.5A rating, 100kA breaking capacity at 400V, and rotary handle. Provides short-circuit protection up to 0.75kW.

Key Features

  • Dedicated magnetic-only trip unit technology with a trip threshold of 33.5 A (13x In)
  • Sturdy rotary handle control providing clear visual status indication (ON/OFF/Tripped)
  • High ultimate breaking capacity (Icu) of 100 kA at voltages up to 500 V AC
  • Dual mounting options supporting 35 mm symmetrical DIN rail clipping or screw panel mounting
  • Secure, vibration-resistant electrical connections via screw clamp terminals
  • Robust mechanical and electrical durability rated for 100,000 operational cycles

Magnetic short-circuit protection designed for 3-phase motors up to 0.75 kW at 400 V AC with a rated current of 2.5 A and 100 kA breaking capacity.

Technical Specification Matrix

ParameterValue
Number of Poles3P
Trip Unit TechnologyMagnetic
Rated Current [In]2.5 A
Magnetic Tripping Current33.5 A
Rated Operational Voltage [Ue]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated Service Short-Circuit Breaking Capacity [Ics]100% at 230/240 V, 400/415 V, 440 V, 500 V, 690 V AC
Rated Ultimate Short-Circuit Breaking Capacity [Icu]100 kA at 230/240 V, 400/415 V, 440 V, 500 V AC; 4 kA at 690 V AC
Control TypeRotary handle
IP RatingIP20 conforming to IEC 60529
Mounting Type35 mm symmetrical DIN rail / Panel screwed (with 2 x M4 screws)
Operating Temperature-20 °C to +60 °C
Mechanical Durability100,000 cycles
Electrical Durability100,000 cycles for AC-3 / AC-3e
Physical Weight (kg)0.33
Dimensions L x W x H (cm)9.7 x 4.5 x 8.9

Industrial Applications

1. Short-Circuit Protection for Small-Scale Industrial Water Pumps

In industrial wastewater treatment systems, small 3-phase centrifugal pumps rated at 0.75 kW (400V) are heavily used and prone to sudden blockages or electrical short-circuits. The GV2L07 provides dedicated magnetic protection, ensuring that in the event of a high-current fault, the system is isolated instantly within milliseconds.

Problem Solved

Prevents upstream power bus collapses and catastrophic stator coil damage by offering a massive 100 kA breaking capacity to interrupt high-fault short circuits immediately without damaging auxiliary controls.

0.75 kW MotorMagnetic Short-Circuit ProtectionCentrifugal Pump Protection100 kA breaking capacityTeSys GV2

2. High-Interruption Protection for HVAC Ventilation Fans

Commercial HVAC ventilation fan motors (rated around 0.75 kW to 1.1 kW at 400-500V AC) operating in dense industrial distribution panels require high-fault current coordination. The GV2L07's magnetic-only trip unit reacts to short-circuit currents at 33.5 A (13 times the nominal 2.5 A rating) to safeguard the motor feeders.

Problem Solved

Eliminates nuisance tripping during normal motor starting currents while providing instant high-speed magnetic disconnection during line-to-line or line-to-ground faults in multi-fan ventilation networks.

HVAC FansRotary Handle DisconnectMagnetic Tripping Current33.5 A Trip ThresholdAC-3 utilisation category

3. Feeder Circuit Protection in Machinery Conveyor Lines

In manufacturing assembly lines, small conveyor belts powered by fractional horsepower motors (1.5 kW at 690 V AC) are managed by centralized motor control centers (MCC). Using the GV2L07 on the 690 V branch ensures dedicated, localized short-circuit protection conforming to IEC 60947-2 standards.

Problem Solved

Avoids widespread factory-floor shutdowns by isolating localized short-circuits on individual conveyor lanes, exploiting the unit's 4 kA breaking capacity at 690 V and allowing the rest of the MCC to continue operating safely.

Conveyor Belt Motor690 V ACFeeder ProtectionIEC 60947-2Screw Clamp Terminals
Select your currency