Schneider A9D32610 Acti9 iDPN N Vigi 10A RCBO

USD 19.90

Acti9 1P+N RCBO, 10A, C curve, 6kA breaking capacity, 30mA Type A earth leakage protection. Features VisiTrip and VisiSafe for enhanced system reliability.

SKU Schneider-A9D32610 Category
Top Brands > Schneider Electric > Schneider Circuit Breakers

Schneider A9D32610 Acti9 iDPN N Vigi 10A RCBO

Model Identifier A9D32610
Official Part Number A9D32610
GTIN Standard 3606480472053

Technical Overview

Acti9 1P+N RCBO, 10A, C curve, 6kA breaking capacity, 30mA Type A earth leakage protection. Features VisiTrip and VisiSafe for enhanced system reliability.

Key Features

  • Provides combined short-circuit, overload, and earth-fault protection in a compact 36 mm module.
  • Features Type A earth leakage sensitivity (30mA) for instantaneous protection against sinusoidal and pulsating DC residual currents.
  • Equipped with VisiTrip red mechanical indicator for rapid identification of earth-leakage and overcurrent faults.
  • Incorporates VisiSafe green indicator to provide visible assurance that the downstream circuit is disconnected and safe.
  • Offers 6000 A (6kA) breaking capacity conforming to EN/IEC 61009-2-1.
  • Class II insulation on the front face for enhanced safety against electric shocks during manual toggle operation.
  • High mechanical and electrical durability rated up to 20,000 cycles.
  • Includes dual-purpose single terminals at top and bottom for rigid (up to 16 mm²) and flexible (up to 10 mm²) cables.

Voltage independent instantaneous earth-leakage protection with 30mA Type A sensitivity and 6kA breaking capacity at 220...240 V AC.

Technical Specification Matrix

ParameterValue
RangeActi9
Product NameActi9 iDPN Vigi
Product or Component TypeResidual current breaker with overcurrent protection (RCBO)
Poles Description1P + N
Number of Protected Poles1
Neutral PositionLeft
Rated Current (In)10 A
Network TypeAC
Curve CodeC
Earth-leakage Sensitivity30 mA
Earth-leakage Protection Time DelayInstantaneous
Earth-leakage Protection ClassType A
Breaking Capacity6000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Suitability for IsolationYes conforming to EN/IEC 60947-2
Network Frequency50 Hz
Rated Operational Voltage (Ue)220...240 V AC 50 Hz
Magnetic Tripping Limit5...10 x In
Residual Current Tripping TechnologyVoltage independent
Rated Service Breaking Capacity (Ics)6000 A 100 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated Insulation Voltage (Ui)400 V AC 50 Hz
Rated Impulse Withstand Voltage (Uimp)4 kV
Control TypeToggle
Local SignallingON, OFF, fault trip (Positive break indication and red mechanical earth-leakage indicator)
Mounting ModeClip-on
Mounting Support35 mm symmetrical DIN rail
9 mm Pitches4
IP Degree of ProtectionIP20 conforming to IEC 60529, IP40 (modular enclosure) conforming to IEC 60529
Overvoltage CategoryIII conforming to IEC 60364
Ambient Air Temperature for Operation-25...60 °C
Ambient Air Temperature for Storage-40...85 °C
Mechanical Durability20000 cycles
Electrical Durability20000 cycles
Tightening Torque2 N.m (top or bottom)
Connections - TerminalsSingle terminal top or bottom 1...16 mm² rigid, 1...10 mm² flexible
Physical Weight (kg)0.13
Dimensions L x W x H (cm)7.3 x 3.6 x 8.5

Industrial Applications

1. Final Distribution and Circuit Protection in Industrial Control Cabinets

Industrial automation enclosures house various control devices, PLCs, and low-power instruments. The Acti9 A9D32610 RCBO provides overcurrent and earth-leakage protection for individual control circuits or auxiliary 230V AC lines within these cabinets. Its compact 36mm DIN-rail footprint (4 x 9mm pitches) allows system integrators to maximize spacing inside the enclosure while ensuring individual line isolation.

Problem Solved

Standard control loops with mixed sensor loads are susceptible to earth-leakage trips and short-circuits. If a single sensor line faults, using a multi-pole group RCD would cause a complete system shutdown. The A9D32610 isolates individual lines, and the VisiTrip indicator allows engineers to instantly locate the faulty circuit without offline diagnostic procedures, drastically reducing troubleshooting time.

DIN rail1P+NVisiTripVisiSafeControl Circuit Protection6kA Breaking CapacityC-Curve

2. Sinusoidal and Pulsating DC Leakage Protection for Variable Speed Drives and Servo Systems

Modern automated assembly lines utilize small variable speed drives (VSDs) and servomotors operating on single-phase AC. These electronic power controllers can introduce high-frequency AC and pulsating DC residual currents into the ground wire under fault conditions, which normal Type AC RCDs cannot detect.

Problem Solved

Standard Type AC earth leakage protectors blind out or fail to trip when pulsating DC residual currents (such as those from rectifiers or drive DC buses) are present. The A9D32610 uses Type A earth-leakage protection class, which is specifically designed to safely detect both AC and pulsating DC ground faults. This prevents hazardous situations from un-tripped leakage current and avoids nuisance tripping.

Type A RCBO30mA SensitivityPulsating DC LeakageVoltage IndependentServo System ProtectionVSD Protection

3. Electrical Safety for Process Instrumentation and Monitoring Stations in Demanding Environments

Process monitoring stations, flow meters, and analysis instruments installed in demanding industrial plants (such as water treatment or chemical manufacturing) are operated continuously in temperatures ranging from -25°C to 60°C and up to 95% relative humidity.

Problem Solved

Standard commercial breakers fail or drift in calibration under wide temperature variations, and moisture can cause internal component corrosion. With an operational temperature rating of -25°C to 60°C and tropicalization compliance (conforming to IEC 60068-1 for tropical environments and 95% RH at 55°C), the A9D32610 ensures robust, reliable protection in high-humidity, high-temperature-swing industrial environments without premature thermal tripping.

Tropicalisation 2-25°C to 60°C Operating Range95% Relative HumidityIP40 Enclosure ProtectionProcess InstrumentationIEC 60068-1