RIF-2-RPT-LDP-24DC/4X21 AU – 2908332 – Relay Module – Phoenix Contact Solid-state Relays And Electromechanical Relays
USD 20.80
24V DC Relay Module with 4 changeover contacts and Push-in connection. Features AgNi hard gold-plated contacts, 250V AC rated insulation, and yellow LED status.
Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.
Commercial Data
| Item number |
2908332 |
| Packing unit |
10 pc |
| Minimum order quantity |
10 pc |
| Sales key |
***** |
| Product key |
DK652I |
| GTIN |
4055626293011 |
| Weight per piece (including packing) |
104.61 g |
| Weight per piece (excluding packing) |
104.61 g |
| Customs tariff number |
85364110 |
| Country of origin |
PL |
Product Properties
| Product type |
Relay Module |
| Product family |
RIFLINE complete |
| Application |
Universal |
| Operating mode |
100% operating factor |
| Mechanical service life |
approx. 2x 107 cycles |
| Insulation characteristics |
| Insulation |
Basic insulation |
| Overvoltage category |
II |
| Pollution degree |
2 |
| Data management status |
| Date of last data management |
20.03.2025 |
Electrical Properties
| Maximum power dissipation for nominal condition |
1.01 W |
| Test voltage (Winding/contact) |
2.5 kVrms (50 Hz, 1 min., winding/contact) |
| Test voltage (Contact/contact) |
2 kVrms (50 Hz, 1 min., contact/contact) |
| Rated insulation voltage |
250 V AC |
| Rated surge voltage |
2.5 kV |
Input Data
| Coil side |
| Nominal input voltage UN |
24 V DC |
| Input voltage range |
19.2 V DC … 30 V DC (20 °C) |
| Input voltage range in reference to UN |
see diagram |
| Drive and function |
monostable |
| Drive (polarity) |
polarized |
| Typical input current at UN |
42 mA |
| Typical response time |
13 ms |
| Typical release time |
14 ms |
| Protective circuit |
Freewheeling diode |
| Status display |
LED (yellow) |
Output Data
| Switching |
| Contact switching type |
4 changeover contacts |
| Type of switch contact |
Single contact |
| Contact material |
AgNi, hard gold-plated |
| Note |
If the specified maximum values for multi-layer contact relays are exceeded, the gold plating is destroyed. The maximum values of the power contact relay are then valid. This can result in a shorter service life than with a pure power contact. |
| Maximum switching voltage |
30 V AC |
| 36 V DC |
| Minimum switching voltage |
2 V (24 mA) |
| Limiting continuous current |
50 mA |
| Maximum inrush current |
50 mA |
| Min. switching current |
2 mA (24 V) |
| Interrupting rating (ohmic load) max. |
1.2 W (at 24 V DC) |
| Switching capacity min. |
48 mW |
| Switching: when the gold layer is destroyed |
| Note |
the following values are applicable if a gold layer is destroyed |
| Contact material |
AgNi |
| Maximum switching voltage |
250 V AC/DC |
| Minimum switching voltage |
5 V (At 24 mA) |
| Limiting continuous current |
6 A |
| Maximum inrush current |
16 A (20 ms, N/O contacts) |
| Min. switching current |
5 mA (at 24 V) |
| Interrupting rating (ohmic load) max. |
144 W (at 24 V DC) |
| 124 W (at 48 V DC) |
| 108 W (at 60 V DC) |
| 52 W (at 110 V DC) |
| 48 W (at 220 V DC) |
| 1500 VA (for 250 V AC) |
| Switching capacity |
2 A (at 24 V, DC13) |
| 0.22 A (at 120 V, DC13) |
| 0.11 A (at 250 V, DC13) |
| 1.5 A (at 24 V, AC15) |
| 1.5 A (at 120 V, AC15) |
| 1 A (at 240 V, AC15) |
Connection Data
| Connection method |
Push-in connection |
| Stripping length |
8 mm |
| Conductor cross section rigid |
0.14 mm² … 1.5 mm² |
| Conductor cross section flexible |
0.14 mm² … 1.5 mm² |
| 0.14 mm² … 1.5 mm² (Ferrule with plastic sleeve) |
| 0.14 mm² … 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block) |
| Conductor cross section AWG |
26 … 16 (solid) |
| 26 … 16 (flexible) |
Dimension
| Item dimensions |
| Width |
31 mm |
| Height |
96 mm |
| Depth |
75 mm |
| Drill hole |
| Diameter |
3.2 mm |
Material Specifications
| Color |
gray (RAL 7042) |
| Flammability rating according to UL 94 |
V2 (Housing) |
Environmental and real-life conditions
| Ambient conditions |
| Degree of protection (Relay base) |
IP20 (Relay base) |
| Degree of protection (Relay) |
RT I (Relay) |
| Ambient temperature (operation) |
-40 °C … 60 °C |
| Ambient temperature (storage/transport) |
-40 °C … 85 °C |
Standards And Regulations
| Standards/regulations |
IEC 60947-5-1 |
Approvals
| Corrosive gas test |
| Identification |
ISA-S71.04. G3 Harsh Group |
| EN 60068-2-60 |
Mounting
| Mounting type |
DIN rail mounting |
| Assembly note |
in rows with zero spacing |
| Mounting position |
any |