Contact Us:
sales@inosaki.com

QUINT4-PS/1AC/24DC/1.3/SC – 2904597 – Phoenix Contact Power Supply

$ 126.50

SKU Phoenix Contact 2904597 Category

Inosaki is one of the largest Phoenix Contact Distributors to provide terminal block, interface module, power supply and relay. And our best offer for terminal block types are Feed-through, Fuse Modular, Spring Cage, Double Level, and Multi-level, hence the series model references to  PT Series, ST Series, TB Series, UT Series, UK Series. In additional for power supply are QUINT Power, STEP Power, Trio Power, and UNO Power. Please email us for catalog: sales@inosaki.my

Product Description

In the power range of up to 100 W, QUINT POWER provides superior system availability in the smallest size. Preventative function monitoring and exceptional power reserves are available for applications in the low-power range.

Dimensions

Article Number 2904597
Width 22.5 mm
Height 99 mm
Depth 90 mm
Installation distance right/left (passive) 5 mm / 5 mm (POut ≥50% )
Installation distance right/left (active) 15 mm / 15 mm (POut ≥50% )
Installation distance top/bottom (active, passive) 30 mm / 30 mm (POut ≤50 %)
Installation distance top/bottom (passive) 30 mm / 30 mm (POut ≥50% )
Installation distance top/bottom (active) 30 mm / 30 mm (POut ≥50% )

Ambient conditions

Degree of protection IP20
Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
Ambient temperature (operation) -25 °C … 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (start-up type tested) -40 °C
Ambient temperature (storage/transport) -40 °C … 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2
Installation height ≤ 5000 m (> 2000 m, observe derating)

Input data

Input voltage range 100 V AC … 240 V AC -15 % … +10 %
110 V DC … 250 V DC -20 % … +40 %
Dielectric strength maximum 300 V AC 30 s
Frequency range (fN) 50 Hz … 60 Hz -10 % … +10 %
Discharge current to PE < 0.25 mA (264 V AC, 60 Hz)
Current consumption 0.46 A (100 V AC)
0.37 A (120 V AC)
0.2 A (230 V AC)
0.2 A (240 V AC)
Nominal power consumption 37 VA
Inrush current typ. 5.9 A (at 25 °C)
Mains buffering time typ. 43 ms (120 V AC)
typ. 43 ms (230 V AC)
Input fuse 3.15 A (slow-blow, internal)
Recommended breaker for input protection 6 A … 16 A (Characteristic B, C or comparable)
Type of protection Transient surge protection
Protective circuit/component Varistor

Output data

Nominal output voltage 24 V DC
Setting range of the output voltage (USet) 24 V DC … 28 V DC (constant capacity)
Nominal output current (IN) 1.3 A
Static Boost (IStat.Boost) 1.625 A (≤ 40 °C)
Dynamic Boost (IDyn.Boost) 2.6 A (≤ 60 °C (5 s))
Derating > 60 °C (2.5%/K)
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Feedback voltage resistance ≤ 35 V DC
Protection against overvoltage at the output (OVP) ≤ 32 V DC
Control deviation < 0.5 % (Static load change 10 % … 90 %)
< 2 % (Dynamic load change 10 % … 90 %, (10 Hz))
< 0.1 % (change in input voltage ±10 %)
Residual ripple < 40 mVPP (with nominal values)
Output power 30 W
Typical response time 500 ms
Maximum power dissipation in no-load condition < 0.4 W (230 V AC)
< 0.4 W (120 V AC)
Power loss nominal load max. < 3.7 W (120 V AC)
< 3.1 W (230 V AC)

General

Net weight 0.188 kg
Environmental protection directive RoHS Directive 2011/65/EU
WEEE
Reach
Efficiency typ. 89.2 % (120 V AC)
typ. 90.7 % (230 V AC)
MTBF (IEC 61709, SN 29500) > 1904000 h (25 °C)
> 1107000 h (40 °C)
> 486000 h (60 °C)
Insulation voltage input/output 4 kV AC (type test)
3 kV AC (routine test)
Degree of protection IP20
Protection class II
Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
Assembly instructions DIN rail mounting

 

Connection data, input

Connection method Screw connection
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.14 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 26
Conductor cross section AWG max. 14
Stripping length 8 mm

Connection data, output

Connection method Screw connection
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.14 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 26
Conductor cross section AWG max. 14
Stripping length 8 mm

Connection data for signaling

Connection method Screw connection
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.14 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 26
Conductor cross section AWG max. 14
Stripping length 8 mm

Standards

EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
EMC requirements, power plant IEC 61850-3
EN 61000-6-5
Standard – Safety of transformers EN 61558-2-16
Standard – Electrical safety IEC 61010-2-201 (SELV)
Standard – safety for equipment for measurement, control, and laboratory use IEC 61010-1
Standard – Safety extra-low voltage IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard – Safe isolation IEC 61558-2-16
Standard – power supply devices for low voltage with DC output EN 61204-3
Standard – Limitation of mains harmonic currents EN 61000-3-2
Overvoltage category EN 61010-1 II (≤ 5000 m)
Overvoltage category EN 62477-1 III (≤ 2000 m)

 

Conformance/approvals

UL approvals UL Listed UL 61010-1
UL Listed UL 61010-2-201
UL 1310 Class 2 Power Units
ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
SIQ CB-Scheme (IEC 61010-1, IEC 61010-2-201)

EMC data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Conducted noise emission EN 55016
EN 61000-6-3 (Class B)
Noise emission EN 55016
EN 61000-6-3 (Class B)
Electrostatic discharge EN 61000-4-2
Contact discharge 8 kV (Test Level 4)
Discharge in air 8 kV (Test Level 3)
Electromagnetic HF field EN 61000-4-3
Frequency range 80 MHz … 1 GHz
Test field strength 20 V/m (Test Level 3)
Frequency range 1 GHz … 6 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst) EN 61000-4-4
Input 4 kV (Test Level 4 – asymmetrical)
Output 4 kV (Test Level X – asymmetrical)
Signal 4 kV (Test Level X – asymmetrical)
Comments Criterion A
Input 2 kV (Test Level 4 – symmetrical)
4 kV (Test Level 4 – asymmetrical)
Output 1 kV (Test Level 3 – symmetrical)
2 kV (Test Level 3 – asymmetrical)
Signal 0.5 kV (Test Level 2 – symmetrical)
Comments Criterion A
Conducted interference EN 61000-4-6
I/O/S asymmetrical
Frequency range 0.15 MHz … 80 MHz
Voltage 10 V (Test Level 3)
Comments Criterion A
Power frequency magnetic field EN 61000-4-8
Frequency 16.67 Hz
50 Hz
60 Hz
Test field strength 100 A/m
Additional text 60 s
Comments Criterion A
Frequency 50 Hz
60 Hz
Frequency range 50 Hz … 60 Hz
Test field strength 1 kA/m
Additional text 3 s
Frequency 0 Hz
Test field strength 300 A/m
Additional text DC, 60 s
Voltage dips EN 61000-4-11
Voltage 100 V AC
Frequency 60 Hz
Voltage dip 70 %
Number of periods 0.5 / 1 / 30 periods
Additional text Test Level 2
Comments Criterion A
Voltage dip 40 %
Number of periods 5 / 10 / 50 periods
Additional text Test Level 2
Comments Criterion B
Voltage dip 0 %
Number of periods 0.5 / 1 / 5 / 50 periods
Additional text Test Level 2
Comments Criterion B
Pulse-shape magnetic field EN 61000-4-9
Test field strength 1000 A/m
Comments Criterion A
Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
Input 2 kV (symmetrical)
4 kV (asymmetrical)
Comments Criterion A
Asymmetrical conducted disturbance variables EN 61000-4-16
Test level 1 16.67 Hz 50 Hz 60 Hz (Test Level 2)
Voltage 30 V (10 s)
Test level 2 16.67 Hz 50 Hz 60 Hz (Test Level 4)
Voltage 300 V (1 s)
Comments Criterion A
Criterion A
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

 

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration”

Additional information

Weight 0.25 kg
Dimensions 9.0 × 2.25 × 9.9 cm

Related Products

SICK_Compact Photoelectric Sensors-GL10-P4112
LOCTITE_SI_596_85g
$ 21.85 - $ 22.31
SICK_sensor_Photoelectric_sensor_W2 Flat_WT2F-E150
SICK_sensors_CM_CM18_08BPP_EW1
Festo_Position sensors_SDAT-MHS-M80-1L-SA-E-03-M8_1531266
EE-SX47 SX67
Select your currency