Q4XTBLAF300-Q8- Q4X SERIES RUGGED LASER DISTANCE SENSOR – Banner Sensors

AUD $ 640.64

SKU: Banner 94118

Banner Sensors

Q4X Series: Laser Adjustable Field

Range: 300 mm; Input 10-30 V dc

Outputs: Bipolar: 1 NPN; 1 PNP

Connection: Euro M12 5-Pin Integral Connector

Specifications

Article Number 94118
Sensing Beam Visible Red Laser
Max Measurement Range >100 mm – <=500 mm
Power DC
PC Configurable No
Sensing Mode (General) Proximity
Sensing Mode (Detailed) Background/Foreground Suppression
Housing Style Rectangular w/M18 Mount
Device Type Sensor
Primary Housing Material Stainless Steel
Laser Classification Class 1
Input/Output Discrete
Indicator Display; LED(s)
Connection Integral QD
Quick Disconnect Type M12 (Euro)
Analog Resolution/Discrete Repeatability 25 mm to 50 mm: +/-0.5; 50 mm to 300 mm: +/- 1% of range
Max Sensing Distance (mm) 300
Minimum Sensing Distance (mm) 25
Power Supply 10-30 V dc
Delay at Power-up (ms) 750
Sensing Beam Wavelength (nm) 655
Adjustments Push Button; Remote Teach
Temperature Effect (mm/°C) +/- 0.05 mm/°C from 25 to 125 mm, +/- 0.35 mm/°C at 300 mm
Number of Pins 5
Vibration MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06″, max acc. 10G).
Mechanical Shock MIL-STD-202G, Meth. 213B, Cond. I (100G 6x along X, Y & Z axes, 18 total shocks) w/ sensor operating
Output Saturation Voltage NPN Outputs <1.0 V @ 100 mA
Output Saturation Voltage PNP Outputs <1.5 V @ 100 mA
Max Discrete (Switched) Output (mA) 100
Discrete (Switched) Outputs Bipolar (NPN & PNP)
Output Protection Protected against continuous overload and short circuit
IP Rating IP67; IP68; IP69
Storage Temperature (°C) -25 to 75
Max Operating Temperature (°C) 50
Min Operating Temperature (°C) -10
Max Op. Relative Humidity Non-Condensing (%) 95 at 55°C
Window Material Acrylic
Warm-up Time (minutes) 10
Minimum Response Time (ms) 1.5
Spot Size (@ Reference Distance) 2.0 mm x 0.8 mm @ 300 mm
Barrel Diameter (mm) 18
Minimum Window Size (mm) 0.4
Discrete Output Hysteresis (mm) Automatically adjusted
Laser Control Yes
Alarm Output (mA) 100
Max Ambient Light (Lux) 5000
Max Off-state Leakage Current (µA) 5 @ 30 V dc
Power/Current Consumption (exclusive of load) < 675 mW
Supply Protection Circuitry Protected against reverse polarity and transient overvoltages
Feature: Remote Teach Yes
Feature: Washdown Rated Yes
Feature: Clear Object Detection Yes
Feature: Timing (Hold/Delay) Yes
Feature: Ecolab Certified Yes
Feature: Chemical Resistant Yes
Feature: Quick Disconnect Yes
Common Ethernet Protocol No
IO Link No
PROFINET No
RS-232 No
RS-422 No
RS-485 No
SSI No
Wireless No
1-wire Serial Interface No
Profibus No