Skip to content

Contact Us:
sales@inosaki.com

SICK 6063624 OD5000-C85W20 Ethernet Displacement Sensor

SICK 6063624 OD5000-C85W20 Ethernet Displacement Sensor

USD 7,148.18

OD5000-C85W20 measures 65–105 mm with Ethernet TCP/IP or UDP, class 1 red laser, configurable input and IP67 housing; AOD1 adds optional outputs.

SKU: SICK-6063624 Category:
Laser Distance Sensors - SICK OD5000

SICK OD5000-C85W20 Ethernet Laser Displacement Sensor

BrandSICK
Model IdentifierOD5000-C85W20
Official Part Number6063624

Technical Overview

The SICK OD5000-C85W20 measures displacement over 65–105 mm using laser triangulation and sends measurement data through native Ethernet TCP/IP or UDP. It also supports 0.5–2 mm transparent-material thickness measurement; reflective-surface distance range is reduced to 71.5–91.5 mm. Measuring frequency reaches 80 kHz only within a sub-area; the stated 0.1 µm repeatability requires 65,536 averages, median 31, 50 µs response and constant parameters on 60% remission white ceramic. A configurable input supports laser-off or external teach-in. Switching and current outputs require a separate AOD1 evaluation unit. The class 1 sensor has an IP67 aluminum housing, status LEDs, a 0.5 m M12 pigtail and warm-up below ten minutes.

65–105 mm laser displacement sensor with native Ethernet, class 1 red laser, configurable input and IP67 housing; analog and switching outputs require AOD1.

Key Features

  • 65–105 mm laser triangulation measuring range
  • 655 nm class 1 red laser; maximum optical power 0.39 mW
  • 0.1 µm repeatability under specified averaging and reference-target conditions
  • Measuring frequency ≤80 kHz; maximum rate restricted to a sub-area
  • Native Ethernet TCP/IP and UDP
  • Configurable input for laser-off, external teach-in or deactivated state
  • Separate AOD1 supports 1–3 selectable PNP/NPN outputs and one 4–20 mA output
  • 12–24 V DC ±10%, including residual ripple; warm-up <10 min
  • 0.5 m cable with M12 8-pin A-coded male connector; Y-distribution supplied
  • IP67 aluminum-diecast housing and PMMA window

Measure non-contact displacement and send values over Ethernet to external inspection or machine control, with settings matched to the required measuring range.

Technical Specification Matrix

ParameterValue
Functional principleLaser triangulation displacement measurement
Measuring range65–105 mm
Repeatability0.1 µm;60% remission white ceramic;65,536 averages,median31,response50 µs,constant application parameters
Diffuse linearity±6 µm;60% remission white ceramic
Specular measurement71.5–91.5 mm range;linearity ±6 µm
Transparent-material thickness0.5–2 mm
Response time≥0.0125 ms;at0.0125 ms only within a sub-range;depends on averaging or sensitivity
Measuring frequency≤80 kHz;80 kHz measurement only within a sub-area
Output time≥0.0125 ms
Light sourceVisible red laser;655 nm
Laser class1;IEC60825-1:2014 and EN60825-1:2014
Maximum optical output0.39 mW
Laser handlingDo not intentionally look into the beam or point it at eyes
Typical light spot70 ×2,000 µm
EthernetNative TCP/IP and UDP
Digital inputIn1;laser off,external teach-in or deactivated
Optional digital outputs1–3 selectable PNP/NPN outputs only via separate AOD1 evaluation unit
Optional analog outputOne4–20 mA output,load≤300 Ω,only via separate AOD1 evaluation unit
Power supply12–24 V DC ±10%,including residual ripple
Current consumption180 mA at24 V
Warm-up time<10 min
DisplayStatus LEDs
Connection0.5 m cable with M12 8-pin A-coded male connector
Included connection accessoryY-distribution;other illustrated connection cables and AOD1 are separate
Housing materialAluminum diecast
Window materialPMMA plastic
IP ratingIP67
Protection classIII;EN50178
Operating temperature−10 to+50 °C at24 V supply
Storage temperature−20 to+60 °C
Relative humidity35–85%;non-condensing
Temperature drift±0.01%FS/K at−10 to+40 °C;±0.03%FS/K at+40 to+50 °C;FS=full sensor measuring range
Ambient light immunityTypical artificial light≤3,000 lx with constant object movement in measuring range;sunlight≤10,000 lx
Vibration resistanceEN60068-2-6 and EN60068-2-64
Shock resistanceEN60068-2-27
MTTFD61 years
DCavg0%
Physical Weight (kg)0.28

Industrial Applications

1. Checking a surface position in an assembly fixture

An assembly fixture can present a diffusely reflecting part surface inside the 65–105 mm measuring range and use its measured displacement as a seating reference. Ethernet carries the values to external inspection logic, which compares the actual surface position with the fixture reference. Sensitivity, averaging and the required warm-up are established on the production material before setting a tolerance.

Problem Solved

Measuring the surface position gives external inspection logic a numerical seating condition, helping distinguish a displaced or incompletely seated part from a part that merely occupies the fixture.

Surface position Assembly inspection Ethernet

2. Inspecting a transparent sheet thickness

A sheet inspection station can place a transparent material of0.5–2 mm thickness in the optical measurement arrangement and configure the sensor to evaluate its surface peaks. External inspection logic receives results over Ethernet and applies limits established with the actual material. Nearby overlapping surfaces must be checked because the manual warns that unresolved adjacent interfaces can merge into one detected peak.

Problem Solved

Resolving the sheet interfaces supplies a thickness condition for external quality checks, helping identify material outside the selected thickness band while retaining the need to validate actual optical returns.

Thickness inspection Surface peaks External limits

3. Monitoring a machine reference position

A machine can place a reference target inside the 65–105 mm range and transmit displacement values to an external positioning controller through Ethernet. The controller interprets departure from its reference and implements the correction strategy. Where hardwired threshold or current signals are required, a separate AOD1 evaluation unit supplies those outputs; controller behavior and achieved precision are validated with the selected sensor settings.

Problem Solved

Continuous position values allow external control to assess the direction and size of a reference movement, supporting a chosen correction strategy instead of relying solely on a binary presence signal.

Reference position External control Optional AOD1