1. Checking a surface position in an assembly fixture
An assembly fixture can present a diffusely reflecting part surface inside the 110–190 mm measuring range and use its measured displacement as a seating reference. Ethernet carries the values to external inspection logic, which compares the actual surface position with the fixture reference. Sensitivity, averaging and the required warm-up are established on the production material before setting a tolerance.
Problem Solved
Measuring the surface position gives external inspection logic a numerical seating condition, helping distinguish a displaced or incompletely seated part from a part that merely occupies the fixture.
Surface position
Assembly inspection
Ethernet
2. Following a rotating part surface
A test station can present a diffusely reflecting rotating part surface within110–190 mm and collect displacement values over Ethernet. External evaluation relates the changing surface position to the rotation reference. Sampling duration and the selected measurement sub-area are matched to the actual excursion; the80 kHz ceiling and heavily averaged static repeatability are not treated as simultaneous performance guarantees.
Problem Solved
A sequence of surface positions lets external evaluation examine changing radial position over a rotation, providing information about surface excursion beyond a single fixed switching threshold.
Surface trace
Ethernet acquisition
Sampling setup
3. Monitoring a machine reference position
A machine can place a reference target inside the 110–190 mm range and transmit displacement values to an external positioning controller through Ethernet. The controller interprets departure from its reference and implements the correction strategy. Where hardwired threshold or current signals are required, a separate AOD1 evaluation unit supplies those outputs; controller behavior and achieved precision are validated with the selected sensor settings.
Problem Solved
Continuous position values allow external control to assess the direction and size of a reference movement, supporting a chosen correction strategy instead of relying solely on a binary presence signal.
Reference position
External control
Optional AOD1