Siemens Power Supply 24 V / 4 A Product Specifications:

Input
Article number 6EP3333-6SB00-0AY0
type of the power supply network 1-phase AC or DC
supply voltage at AC
● minimum rated value 100 V
● maximum rated value 240 V
● initial value 85 V
● full-scale value 264 V
input voltage
● at DC 110 … 300 V
design of input wide range input Yes
overvoltage overload capability 300 V AC for 1 s
operating condition of the mains buffering at Vin = 187 V
buffering time for rated value of the output current in the 40 ms
event of power failure minimum
operating condition of the mains buffering at Vin = 187 V
line frequency
● 1 rated value 50 Hz
● 2 rated value 60 Hz
line frequency 47 … 63 Hz
input current
● at rated input voltage 120 V 1.95 A
● at rated input voltage 230 V 0.97 A
current limitation of inrush current at 25 °C maximum 31 A
I2t value maximum 2.5 A²·s
fuse protection type internal
● in the feeder Recommended miniature circuit breaker: from 10 A characteristic B or from 6 A characteristic C
Output
voltage curve at output Controlled, isolated DC voltage
output voltage at DC rated value 24 V
output voltage
● at output 1 at DC rated value 24 V
relative overall tolerance of the voltage 3%
relative control precision of the output voltage
● on slow fluctuation of input voltage 0.1%
● on slow fluctuation of ohm loading 0.1%
residual ripple
● maximum 200 mV
● typical 30 mV
voltage peak
● maximum 300 mV
● typical 50 mV
adjustable output voltage 22.2 … 26.4 V
product function output voltage adjustable Yes
type of output voltage setting via potentiometer
display version for normal operation Green LED for output voltage OK
behavior of the output voltage when switching on No overshoot of Vout (soft start)
response delay maximum 0.5 s
voltage increase time of the output voltage
● typical 100 ms
output current
● rated value 4 A
● rated range 0 … 4 A; +55 … +70 °C: Derating 2%/K
supplied active power typical 96 W
product feature
● bridging of equipment Yes
number of parallel-switched equipment resources for 2
increasing the power
Efficiency 89%
efficiency in percent
power loss [W] 12 W
● at rated output voltage for rated value of the output
current typical 0.3 W
● during no-load operation maximum
Closed-loop control 0.2%
relative control precision of the output voltage with rapid
fluctuation of the input voltage by +/- 15% typical
relative control precision of the output voltage at load step 2%
of resistive load 10/90/10 % typical
setting time
● load step 10 to 90% typical 1 ms
● load step 90 to 10% typical 1 ms
Protection and monitoring
design of the overvoltage protection Yes, according to EN 60950-1
response value current limitation typical 5 A
property of the output short-circuit proof Yes
design of short-circuit protection Constant current characteristic
enduring short circuit current RMS value
● maximum 5 A
overcurrent overload capability in normal operation overload capability 150% lout rated typ. 200 ms
display version for overload and short circuit
measuring point for output current 50 mV =^ 4 A
overcurrent overload capability when switching on 150% Iout rated typ. 200 ms
Safety
galvanic isolation between input and output Yes
galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
operating resource protection class Class II (without protective conductor)
protection class IP IP20
Approvals
certificate of suitability
● CE marking Yes
● UL approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950, CSA C22.2 No. 60950), File E151273
● CSA approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950, CSA C22.2 No. 60950), File E151273
● cCSAus, Class 1, Division 2 No
● ATEX No
certificate of suitability
● IECEx No
● NEC Class 2 No
● ULhazloc approval No
● FM registration No
type of certification CB-certificate Y Yes
certificate of suitability
● EAC approval Yes
certificate of suitability shipbuilding approval Yes
shipbuilding approval ABS, BV, DNV GL, LRS
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) Yes
● French marine classification society (BV) Yes
● DNV GL Yes
● Lloyds Register of Shipping (LRS) Yes
● Nippon Kaiji Kyokai (NK) No
EMC
standard
● for emitted interference EN 55022 Class B
● for mains harmonics limitation EN 61000-3-2
● for interference immunity EN 61000-6-2
environmental conditions
ambient temperature
● during operation -25 … +70 °C; with natural convection
● during transport -40 … +85 °C
● during storage -40 … +85 °C
environmental category according to IEC 60721 Climate class 3K3, 5 … 95% no condensation
Mechanics
type of electrical connection screw-type terminals
● at input L, N: 1 screw terminal each for 0.5 … 2.5 mm2 single-core/finely stranded
● at output +, -: 1 screw terminal each for 0.5 … 2.5 mm²
● for auxiliary contacts
width of the enclosure 72 mm
height of the enclosure 90 mm
depth of the enclosure 53 mm
required spacing
● top 20 mm
● bottom 20 mm
● left 0 mm
● right 0 mm
net weight 0.29 kg
product feature of the enclosure housing can be lined up Yes
fastening method Snaps onto DIN rail EN 60715 35×7.5/15, direct mounting in different mounting positions
MTBF at 40 °C 2 391 480 h
other information Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)
Weight 0.300 kg
Dimensions 6.7 × 9.6 × 9.1 cm