Limit Switches OsiSense XC Standard – XCKS – Schneider Limit Switches

USD $ 37.38USD $ 45.15

SKU: N/A

Specifications

Main
Part Number XCKS149 XCKS102 XCKS101 XCKS131
Range of product Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Series name Standard format Standard format Standard type Standard type
Product or component type Limit switch Limit switch Limit switch Limit switch
device short name XCKS XCKS XCKS XCKS
Sensor design Form C conforming to CENELEC EN 50041 Type B conforms to CENELEC EN 50041 Type A conforms to CENELEC EN 50041
body type Fixed Fixed Fixed Fixed
Head type Rotary head Plunger head Direct acting head Swivel head
Material Plastic Plastic Plastic Plastic
Body material Plastic Plastic Plastic Plastic
Head material Plastic Plastic Plastic Plastic
Fixing mode By the body By the body By ontology By ontology
Movement of operating head Rotary Linear Linear To rotate
Type of operator Spring return roller lever elastomer variable length, roller diameter 50 mm Spring return roller plunger metal Spring return direct acting metal Spring Return Roller Rocker Thermoplastic
Type of approach Lateral approach, 1 or 2 programmable direction Lateral approach, 2 directions Vertical movement, one-way Side movement, 1 or 2 directions programmable
Cable entry 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm
Number of poles 2 2 2 2
Contacts type and composition 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO
Contact operation Snap action Snap action Momentary Momentary
Complementary
Switch actuation By 30° cam By 30° cam The end 30° lip
Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm²
Contacts insulation form Zb Zb Zb Zb
Number of steps 1 1 1 1
Positive opening With With Have Have
Force open minimum torque 0.15 Nm
Minimum torque for tripping 0.1 N.m 0.1 Nm
Minimum actuation speed 0.01 m/min 0.01 m/min 0.01 m/min 0.01 m/min
Positive opening minimum force 20 N 30N
Minimum force for tripping 12 N 15N
Maximum actuation speed 1.5 m/s 0.5 m/s 0.5 m/s 1.5 m/s
Repeatability Trigger point is 0.05mm 1 million operating cycles
Contact code designation A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A
[Ithe] conventional enclosed thermal current 10 A AC 10 A AC 10A AC 10A AC
[Ui] rated insulation voltage 300 V conforming to UL 508 300 V conforming to UL 508 300 V according to UL 508 300 V according to UL 508
500 V (pollution degree 3) conforming to IEC 60947-1 500 V (pollution degree 3) conforming to IEC 60947-1 500 V (pollution degree 3) according to IEC 60947-1 500 V (pollution degree 3) according to IEC 60947-1
300 V conforming to CSA C22.2 No 14 300 V conforming to CSA C22.2 No 14 300 V according to CSA C22.2 No 14 300 V according to CSA C22.2 No 14
Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3 25 MOhm conforming to IEC 60255-7 category 3 25 MΩ conforming to IEC 60255-7 Safety Class 3 25 MΩ conforming to IEC 60255-7 Safety Class 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60664 6 kV conforming to IEC 60664 6 kV according to IEC 60664 6 kV according to IEC 60664
6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60947-1 6 kV according to IEC 60947-1 6 kV according to IEC 60947-1
Short-circuit protection 10 A cartridge fuse, type gG 10 A cartridge fuse, type gG 10 A fuse fuse, type gG 10 A fuse fuse, type gG
Electrical durability 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive
5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C
Mechanical durability 20000000 cycles 15000000 cycles 25000000 times 20000000 times
Width 50 mm 40 mm 40 mm 40 mm
Height 133…188 mm 117 mm 104 mm 130mm
Depth 65 mm 37 mm 37 mm 60 mm
Product weight 0.18 kg 0.133 kg 0.125 kg 0.16kg
Terminals description ISO n°1 (21-22)NC (13-14)NO (21-22)NC (13-14)NO
(13-14)NO (21-22)NC (13-14)NO (21-22)NC
Environment
Shock resistance 40 gn for 11 ms conforming to IEC 60068-2-27 40 gn for 11 ms conforming to IEC 60068-2-27 40 gn for 11 ms conforming to IEC 60068-2-27 40 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance 20 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP degree of protection IP67 conforming to IEC 60529 IP67 conforming to IEC 60529 IP67 conforms to screwed IP67 conforms to screwed
IP66 conforming to IEC 60529 IP66 conforming to IEC 60529 IP66 conforms to screwed IP66 conforms to screwed
IK degree of protection IK05 conforming to EN 50102 IK05 conforming to EN 50102 IK05 conforms to EN 50102 IK05 conforms to EN 50102
Electrical shock protection class Class II conforming to IEC 61140 Class II conforming to IEC 61140 Class II conforms to IEC 61140 Class II conforms to IEC 61140
Class II conforming to NF C 20-030 Class II conforming to NF C 20-030 Class II conforms to NF C 20-030 Class II conforms to NF C 20-030
Overvoltage category Class II conforming to IEC 61140 Class II conforming to IEC 61140 Class II conforms to IEC 61140 Class II conforms to IEC 61140
Class II conforming to NF C 20-030 Class II conforming to NF C 20-030 Class II conforms to NF C 20-030 Class II conforms to NF C 20-030
Ambient air temperature for operation -25…70 °C -25…70 °C -25…70°C -25…70°C
Ambient air temperature for storage -40…70 °C -40…70 °C -40…70°C -40…70°C
Protective treatment TC TC TC TC
Product certifications CSA UL CCC UL
UL CCC UL CSA
CCC CSA CSA CCC
Standards EN 60204-1 UL 508 EN 60947-5-1 IEC 60947-5-1
IEC 60947-5-1 IEC 60947-5-1 UL 508 EN 60947-5-1
UL 508 CSA C22.2 No 14 IEC 60204-1 UL 508
IEC 60204-1 CENELEC EN 50041 CSA C22.2 No 14 CSA C22.2 No 14
CENELEC EN 50041 EN 60947-5-1 CENELEC EN 50041 CENELEC EN 50041
CSA C22.2 No 14 EN 60204-1 EN 60204-1 IEC 60204-1
EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 EN 60204-1
Packing Units
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 5.000 cm 4.0 cm 4cm 4.2 cm
Package 1 Width 9.000 cm 6.0 cm 6cm 9.6cm
Package 1 Length 15.300 cm 13.5 cm 13.2 cm 13.2 cm
Package 1 Weight 214.000 g 150.0 g 144g 176.0g
Unit Type of Package 2 S02 S02 S02 S02
Number of Units in Package 2 12 36 36 Twenty two
Package 2 Height 15.000 cm 15.0 cm 15cm 15.0cm
Package 2 Width 30.000 cm 30.0 cm 30cm 30.0cm
Package 2 Length 40.000 cm 40.0 cm 40cm 40.0cm
Package 2 Weight 3.010 kg 5.923 kg 5.603 kg 4.364 kg
Contractual warranty
Warranty 18 months 18 months 18 months 18 months

 

Main information
Part Number XCKS131H29 XCKS141 XCKS159
Product Series Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Serial Number Standard type Standard type Standard type
product type Limit switch Limit switch Limit switch
product short name XCKS XCKS XCKS
sensor design Type A conforms to CENELEC EN 50041 Form D conforms to CENELEC EN 50041
ontology type Fixed Fixed Fixed
Control head type Swivel head Swivel head Swivel head
Material Plastic Plastic Plastic
body material Plastic Plastic Plastic
head material Plastic Plastic Plastic
fixed mode By ontology By ontology By ontology
Operation head movement To rotate To rotate To rotate
Operating head type Spring Return Roller Rocker Thermoplastic Spring Return Roller Rocker Thermoplastic Variable Length Spring Return, Round Rod Rocker Thermoplastic Round Rod 6 mm, L = 200 mm
method type Side movement, 1 or 2 directions programmable Side movement, 1 or 2 directions programmable Side movement, 1 or 2 directions programmable
cable entry hole 1 cable gland for M20x1.6, outer cable diameter: 7…13 mm 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm
number of poles 2 2 2
contact type 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO
contact action Momentary Momentary Momentary
Additional information
switch trigger 30° lip 30° lip Any moving parts
Electrical connections Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm²
Type of contact wire insulation Zb Zb Zb
Step count 1 1 1
force open Have Have None
Force open minimum torque 0.15 Nm
Minimum trigger torque 0.1 Nm 0.1 Nm 0.1 Nm
minimum braking speed 0.01 m/min 0.01 m/min 0.01 m/min
operating speed 1.5 m/s 1.5 m/s 1 m/s
Contact wire regulation grade A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A
Rated load current in case [Ithe] 10A AC 10A AC 10A AC
Rated insulation voltage [Ui] 300 V according to UL 508 300 V according to UL 508 300 V according to UL 508
500 V (pollution degree 3) according to IEC 60947-1 500 V (pollution degree 3) according to IEC 60947-1 500 V (pollution degree 3) according to IEC 60947-1
300 V according to CSA C22.2 No 14 300 V according to CSA C22.2 No 14 300 V according to CSA C22.2 No 14
Maximum resistance across terminals 25 MΩ conforming to IEC 60255-7 Safety Class 3 25 MΩ conforming to IEC 60255-7 Safety Class 3 25 MΩ conforming to IEC 60255-7 Safety Class 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60664 6 kV according to IEC 60664 6 kV according to IEC 60664
6 kV according to IEC 60947-1 6 kV according to IEC 60947-1 6 kV according to IEC 60947-1
Short circuit protection 10 A fuse fuse, type gG 10 A fuse fuse, type gG 10 A fuse fuse, type gG
Electrical life 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive
load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive load Type, 24 V, 10 W, Operating rating <60 cycles/min, Duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5,000,000 cycles, DC-13,
loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C Inductive load Load type, 48 V, 7 W, Operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C
Mechanical life 20000000 times 20000000 times 20000000 times
width 40 mm 40 mm 40 mm
high 130mm 117…172mm 98…280mm
depth 60 mm 57 mm 55 mm
product weight 0.16kg 0.165 kg 0.17 kg
ISO n°1 terminals (13-14)NO (13-14)NO (13-14)NO
(21-22)NC (21-22)NC (21-22)NC
Environment
impact resistance 40 gn for 11 ms conforming to IEC 60068-2-27 40 gn for 11 ms conforming to IEC 60068-2-27 40 gn for 11 ms conforming to IEC 60068-2-27
Anti-vibration 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP protection class IP67 conforms to screwed IP67 conforms to screwed IP67 conforms to screwed
IP66 conforms to screwed IP66 conforms to screwed IP66 conforms to screwed
IK protection class IK05 conforms to EN 50102 IK05 conforms to EN 50102 IK05 conforms to EN 50102
Electric Shock Protection Level Class II conforms to IEC 61140 Class II conforms to IEC 61140 Class II conforms to IEC 61140
Class II conforms to NF C 20-030 Class II conforms to NF C 20-030 Class II conforms to NF C 20-030
Type of overvoltage Class II conforms to IEC 61140 Class II conforms to IEC 61140 Class II conforms to IEC 61140
Class II conforms to NF C 20-030 Class II conforms to NF C 20-030 Class II conforms to NF C 20-030
operating temperature -25…70°C -25…70°C -25…70°C
storage environment temperature -40…70°C -40…70°C -40…70°C
Protective treatment TC TC TC
certified product CCC UL CCC
UL CSA CSA
CSA CCC UL
Standards compliant EN 60204-1 UL 508 UL 508
CSA C22.2 No 14 IEC 60204-1 EN 60947-5-1
IEC 60947-5-1 EN 60947-5-1 CSA C22.2 No 14
EN 60947-5-1 IEC 60947-5-1 EN 60204-1
UL 508 CENELEC EN 50041 CENELEC EN 50041
IEC 60204-1 EN 60204-1 IEC 60947-5-1
CENELEC EN 50041 CSA C22.2 No 14 IEC 60204-1
Packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 4.2 cm 4.100 cm 4.2 cm
Package 1 Width 9.4 cm 9.600 cm 5.8cm
Package 1 Length 12.8 cm 13.200 cm 20.8 cm
Package 1 Weight 176.0g 186.000g 184.0g
Unit Type of Package 2 S02 S02 S02
Number of Units in Package 2 Twenty two Twenty two 18
Package 2 Height 15.0cm 15.000 cm 15.0cm
Package 2 Width 30.0cm 30.000 cm 30.0cm
Package 2 Length 40.0cm 40.000 cm 40.0cm
Package 2 Weight 4.39kg 4.626 kg 3.825 kg
Contract warranty
Warranty 18 months 18 months 18 months
Weight 0.180 kg
Dimensions 6.50 × 5.0 × 18.80 cm
Model

, , , , , ,