Skip to content

Contact Us:
sales@inosaki.com

SICK 6069277 IMR18-08BPSTC0S Inductive Proximity Sensor

SICK 6069277 IMR18-08BPSTC0S Inductive Proximity Sensor

USD 139.10

Flush M18 inductive sensor with 8 mm nominal range, factor-1 metal detection, magnetic-field resistance, PNP NO output, 1,500 Hz switching and IP68.

SKU: SICK-6069277 Category:
SICK IMR

SICK IMR18-08BPSTC0S Inductive Proximity Sensor

BrandSICK
Model IdentifierIMR18-08BPSTC0S
Official Part Number6069277

Technical Overview

The SICK IMR18-08BPSTC0S is a flush-mount M18 inductive proximity sensor for welding areas and difficult application conditions. It has an 8 mm nominal sensing range and 6.4 mm assured sensing range, with reduction factor 1 specified for stainless steel V2A/304, aluminum, copper and brass as reference values that may vary. Magnetic-field resistance is specified up to 100 mT. The PNP normally-open output uses DC three-wire wiring through an M12 four-pin connector, with 1,500 Hz switching. A PTFE-coated brass housing, PTFE-coated plastic sensing face, IP68 protection and −30 to +85 °C operating range support installation, powered from 10–30 V DC.

Flush M18 inductive sensor with 8 mm nominal range, factor-1 metal detection, magnetic-field resistance, 1,500 Hz PNP NO output and M12 connector.

Key Features

  • M18 × 1 metric thread; flush installation
  • 8 mm nominal range; 6.4 mm assured sensing range
  • Reduction factor 1 for listed stainless steel, aluminum, copper and brass targets
  • Magnetic-field-resistant; specified field strength ≤100 mT
  • PNP normally-open output; DC three-wire; 1,500 Hz switching
  • 10–30 V DC supply; continuous output current ≤200 mA
  • M12 four-pin male connector; pin 4 NO; pin 2 unconnected
  • PTFE-coated brass housing and PTFE-coated plastic sensing face
  • IP68; −30 to +85 °C operation
  • Two PTFE-coated brass mounting nuts and two toothed washers supplied

Use factor-1 metal detection and magnetic-field resistance to monitor qualified metal targets in welding-area machine fixtures.

Technical Specification Matrix

ParameterValue
Functional principleInductive metal proximity detection
Housing formMetric cylindrical, standard design
Housing threadM18 × 1
Body diameter18 mm
Sensing range Sn8 mm nominal
Assured sensing range Sa6.4 mm
InstallationFlush
Switching frequency1,500 Hz
Switching outputPNP
Output functionNormally open (NO)
Electrical wiringDC three-wire
ConnectionM12 four-pin male connector
Pin assignment1/BN: L+; 4/BK: NO; 3/BU: M; 2: not connected
Special featuresReduction factor 1; magnetic-field-resistant
Specified application environmentWelding areas and difficult application conditions
Power supply10–30 V DC
Residual ripple≤10%
Voltage drop≤1.8 V at maximum output current Ia
Hysteresis3–15%
Reproducibility≤2% of Sr at constant supply voltage and ambient temperature
Continuous output current≤200 mA
No-load current≤15 mA
Off-state current≤0.1 mA
Circuit protectionShort-circuit protection
Magnetic field strength≤100 mT
Shock resistance30 g, 11 ms
Vibration resistance10–55 Hz, 1 mm
Operating temperature−30 to +85 °C
Housing materialPTFE-coated brass
Sensing face materialPTFE-coated plastic
Housing length52 mm
Thread length36 mm
Nut width across flats24 mm
Protection classII; reference voltage 50 V DC
UL fileE191603
MTTFD139 years
Diagnostic coverage DCavg0%
Mission time20 years
Target-material reduction factorsReference values, may vary: stainless steel V2A/304=1; aluminum=1; copper=1; brass=1
Mounting clearancesA=18 mm; B=18 mm; C=18 mm; D=24 mm; E=0 mm; F=48 mm; G=54 mm; follow manufacturer installation diagram
Items suppliedTwo PTFE-coated brass mounting nuts; two PTFE-coated brass washers with locking teeth
IndicatorYellow output-state LED

Industrial Applications

1. Confirming a welding fixture clamp position

A welding fixture can present a qualified metal clamp feature to the sensor at its designated end position. The magnetic-field-resistant design is specified for welding areas, with a field-strength limit of 100 mT. The PNP normally-open output reports the local clamp position to the machine controller, subject to the required flush mounting and installation clearances.

Problem Solved

A noncontact clamp-position input helps the machine controller coordinate its fixture sequence in the specified magnetic-field environment, without a mechanical contact switch at the monitored clamp point.

Welding fixture 100 mT PNP NO

2. Checking component presence across different metal batches

An assembly station can present qualified components from stainless steel V2A/304, aluminum, copper or brass batches at the same inspection location. The listed material reduction factors are all 1 as reference values that may vary. The 8 mm nominal range and 6.4 mm assured range guide placement, while the PNP signal reports presence rather than identifying the alloy.

Problem Solved

The presence signal supports missing-component checks across the listed metal batches, reducing the need to select a different reduction factor for each listed target material during initial sensor selection.

Mixed-metal batches Factor 1 Presence

3. Indexing a metal tool carrier

A metal tool carrier can move a qualified reference feature past the sensing face at a machine station. The external controller reads one output transition as the carrier reference. The 1,500 Hz switching frequency, 3–15% hysteresis and specified reproducibility define switching limits, while the M12 connector links the DC three-wire output to compatible controls.

Problem Solved

A local tool-carrier reference event helps coordinate station timing without a mechanical cam switch, leaving counting, dwell control and subsequent machine actions to the external controller.

Tool-carrier index 1,500 Hz M12 connection