1. Confirming a welding fixture clamp position
A welding fixture can present a qualified metal clamp feature to the sensor at its designated end position. The magnetic-field-resistant design is specified for welding areas, with a field-strength limit of 100 mT. The PNP normally-open output reports the local clamp position to the machine controller, subject to the required flush mounting and installation clearances.
Problem Solved
A noncontact clamp-position input helps the machine controller coordinate its fixture sequence in the specified magnetic-field environment, without a mechanical contact switch at the monitored clamp point.
Welding fixture
100 mT
PNP NO
2. Checking component presence across different metal batches
An assembly station can present qualified components from stainless steel V2A/304, aluminum, copper or brass batches at the same inspection location. The listed material reduction factors are all 1 as reference values that may vary. The 8 mm nominal range and 6.4 mm assured range guide placement, while the PNP signal reports presence rather than identifying the alloy.
Problem Solved
The presence signal supports missing-component checks across the listed metal batches, reducing the need to select a different reduction factor for each listed target material during initial sensor selection.
Mixed-metal batches
Factor 1
Presence
3. Indexing a metal tool carrier
A metal tool carrier can move a qualified reference feature past the sensing face at a machine station. The external controller reads one output transition as the carrier reference. The 1,500 Hz switching frequency, 3–15% hysteresis and specified reproducibility define switching limits, while the M12 connector links the DC three-wire output to compatible controls.
Problem Solved
A local tool-carrier reference event helps coordinate station timing without a mechanical cam switch, leaving counting, dwell control and subsequent machine actions to the external controller.
Tool-carrier index
1,500 Hz
M12 connection