SICK 1040734 IME12-02BPSZW2S 2 mm PNP Inductive Sensor

USD 30.16

IME12-02BPSZW2S provides 2 mm nominal inductive sensing, flush M12 mounting, PNP normally open output, 2000 Hz switching and a 2 m PVC cable.

SKU SICK-1040734 Category
SICK IME

SICK IME12-02BPSZW2S PNP Normally Open Inductive Sensor

BrandSICK
Model IdentifierIME12-02BPSZW2S
Official Part Number1040734

Technical Overview

The SICK IME12-02BPSZW2S is an M12 ×1 inductive proximity sensor for flush installation in metal. It specifies 2 mm nominal sensing distance and 1.62 mm assured sensing distance, with a PNP normally open output in a DC three-wire arrangement. Switching frequency is 2,000 Hz, supply is 10–30 V DC and continuous output current is no more than 200 mA. The nickel-plated brass housing and PA66 sensing face have IP67 protection for −25 to +75 °C operation. A 2 m three-wire PVC cable connects the device, and two nickel-plated brass mounting nuts are supplied. Actual target material, gap and surrounding metal must match the documented reduction factors and installation clearances.

Flush M12 inductive sensor with 2 mm nominal range, PNP normally open output, 2,000 Hz switching and 2 m PVC cable.

Key Features

  • M12 ×1 inductive sensor for flush installation
  • Nominal sensing distance Sn 2 mm; assured sensing distance Sa 1.62 mm
  • PNP normally open output; DC three-wire wiring
  • 2,000 Hz switching frequency
  • 10–30 V DC; ≤200 mA continuous output current; ≤10 mA without load
  • ≤100 ms delay before availability; short-circuit and power-up pulse protection
  • 2 m three-wire PVC cable
  • Nickel-plated brass housing; PA66 sensing face
  • Two nickel-plated brass mounting nuts supplied; maximum tightening torque ≤12 Nm
  • IP67 to EN 60529; −25 to +75 °C operation

Detect a nearby metal target through flush inductive sensing and supply a PNP normally open state to compatible external control.

Technical Specification Matrix

ParameterValue
Functional principleInductive proximity sensing
Housing designStandard metric body
Housing threadM12 ×1; Ø12 mm
InstallationFlush
Nominal sensing distance Sn2 mm
Assured sensing distance Sa1.62 mm
Switching outputPNP, normally open
Electrical wiringDC three-wire
Switching frequency2,000 Hz
Connection2 m three-wire PVC cable
Power supply10–30 V DC
Ripple≤10%
Voltage drop≤2 V at maximum output current
Delay before availability≤100 ms
Hysteresis5–15%
Reproducibility≤2% of Sr at constant supply voltage and ambient temperature
Temperature drift±10% of Sr
Continuous output current≤200 mA
No-load current≤10 mA
Electrical protectionShort-circuit protection and power-up pulse protection
EMCEN 60947-5-2
Shock resistance30 g for 11 ms
Vibration resistance10–55 Hz, 1 mm
Operating temperature−25 to +75 °C
Housing materialNickel-plated brass
Sensing-face materialPA66 plastic
Housing length63 mm
Thread length48 mm
Maximum tightening torque≤12 Nm
Items suppliedTwo nickel-plated brass mounting nuts; width across flats 17
IP ratingIP67, EN 60529
UL fileNRKH.E181493
MTTFD1,735 years
Diagnostic coverageDCavg 0%
Reduction factorsReference values, may vary: St37 steel 1; V2A/304 stainless approx. 0.8; aluminum approx. 0.45; copper approx. 0.4; brass approx. 0.4
Installation clearancesB=24 mm; C=12 mm; D=12 mm; F=32 mm
Cable materialPVC
Conductor cross-section0.25 mm²
Cable diameter3.9 mm
Wire assignmentCD-001: BN=L+; BK=NO output; BU=M

Industrial Applications

1. Confirming a metal carriage at its stop

A machine carriage can present a metal feature inside the sensor’s commissioned inductive range and feed the PNP normally open state to external sequencing logic. The flush mounting arrangement follows the documented clearances around metal structure. Setup checks actual target material and gap against the assured sensing distance and reduction factors before using the condition as a process-position reference.

Problem Solved

A metal-carriage arrival condition helps external sequencing coordinate the next process step, using an installed target gap and mounting geometry checked for the actual material.

Carriage stop Flush installation PNP output

2. Counting separated metal components through a guide

A guide can move separated metal components past the inductive sensing face and send output transitions to external counting electronics. Commissioning establishes the target gap and checks the effect of actual metal composition using the documented reduction factors. Part transit time and gaps are tested against the 2,000 Hz switching specification, while the connected input respects the output-current limit.

Problem Solved

A discrete metal-part passage signal helps external counting electronics register separated components, using commissioned target geometry and switching conditions matched to the actual feed.

Metal-part count Inductive sensing Switching frequency

3. Deriving rotation rate from a metal cam

A rotating mechanism can present a metal cam or marker to the sensor once per known mechanical interval. External timing electronics derive rotation rate from the PNP output transitions and the actual number of markers per turn. Setup checks target material, clearances and gap, then verifies the pulse pattern at the required speed against the sensor’s switching frequency and startup availability.

Problem Solved

A recurring metal-marker signal helps external timing electronics derive rotation rate from discrete transitions, using the commissioned marker count and verified sensing geometry for the rotating mechanism.

Cam timing Rotation rate External calculation
Select your currency