SICK 6041792 IMA12-06BE3ZC0K Analog Inductive Sensor

SICK 6041792 IMA12-06BE3ZC0K Analog Inductive Sensor

USD 172.64

M12 quasi-flush analog inductive sensor with 0–6 mm sensing range, 0–10 V output, 1000 Hz bandwidth, 15–30 V DC supply and IP67 protection.

SKU: SICK-6041792 Category:
SICK IMA

SICK IMA12-06BE3ZC0K Analog Inductive Sensor

BrandSICK
Model IdentifierIMA12-06BE3ZC0K
Official Part Number6041792

Technical Overview

The SICK IMA12-06BE3ZC0K is an M12 quasi-flush analog inductive sensor for monitoring the position of a qualified metal target over a 0–6 mm sensing range. Its QA1 output supplies a 0–10 V signal. External analog equipment can evaluate the signal against a calibrated target-distance relationship. The sensor has a 1000 Hz bandwidth at −3 dB with the target at 3 mm and becomes available within 50 ms. A M12 four-pin male connector supports electrical integration. The chromium-plated brass housing has a plastic sensing face and IP67 protection. Supply voltage is 15–30 V DC; operation is specified from −25 to +70 °C.

M12 quasi-flush analog inductive sensor with 0–6 mm range, 0–10 V QA1 output, 1000 Hz bandwidth and M12 four-pin male connector.

Key Features

  • M12 ×1 metric housing; quasi-flush installation
  • 0–6 mm sensing range
  • 0–10 V analog voltage output QA1
  • 1000 Hz bandwidth at −3 dB and 3 mm target distance
  • Availability ≤50 ms; 15–30 V DC supply
  • ±0.01 mm repeatability at constant ambient temperature
  • Resolution ≤1 µm
  • M12 four-pin male connector
  • Chromium-plated brass housing; plastic sensing face; IP67
  • Short-circuit protection; two chromium-plated brass mounting nuts supplied

Provide an analog metal-target position signal over 0–6 mm for external monitoring and calibrated machine control.

Technical Specification Matrix

ParameterValue
Functional principleAnalog inductive metal-target position sensing
Housing formMetric cylindrical
Housing threadM12 ×1
Body diameter12 mm
Sensing range0–6 mm
InstallationQuasi-flush
Output functionAnalog
Analog voltage output QA10–10 V
ConnectionM12 four-pin male connector
Power supply15–30 V DC
Ripple≤20% of supply voltage
Time delay before availability≤50 ms
Repeatability at constant temperature±0.01 mm
Repeatability with varying temperature0.3 mm per IEC 60947-5-2; supply20–30 V DC; ambient23 °C ±5 °C
Bandwidth1000 Hz at −3 dB, target distance 3 mm
No-load current≤12 mA without load
Short-circuit protectionProvided
Housing materialChromium-plated brass
Sensing face materialPlastic
Housing length45 mm
Thread length29 mm
IP ratingIP67 per EN60529:2000-09
MTTFD88 years
Diagnostic coverage DCavg0%
Mission time20 years
Mounting clearancesA=6 mm; B=18 mm; C=12 mm; D=18 mm; E=2 mm; F=60 mm; follow manufacturer installation instructions
Nut width across flats17 mm
Items suppliedTwo chromium-plated brass mounting nuts and two stainless-steel toothed washers
Resolution≤1 µm
QA1 reference pointsAt23 °C: s=0 mm,0 V (−0/+0.4 V); s=3 mm,5.2 V ±0.4 V; s=6 mm,10 V ±0.4 V
Operating temperature−25 to +70 °C
Temperature drift±5% of Sr at0 to+70 °C; ±10% of Sr at−25 to0 °C
QA1 load current±10 mA at voltage output
Pin assignment1/BN=L+; 3/BU=M; 4/BK=QA1 voltage; CD-021; remaining pin not assigned in sheet
Target-material reduction factorsApproximate reference values that may vary: V2A/304=0.47; aluminum=0.28; copper=0.2; brass=0.35

Industrial Applications

1. Monitoring a metal strip gap at a guide

A metal-strip guide can use the analog voltage signal to monitor a qualified strip surface within the specified sensing range. External analog equipment converts the signal through a calibrated relationship for the actual metal and geometry, then compares the result with the permitted guide-gap band. The noncontact arrangement follows local displacement without a sensing roller touching the monitored surface.

Problem Solved

An analog gap signal exposes local strip-position variation to the external controller, supporting guide adjustment without requiring a contact measurement follower against the moving qualified metal surface.

Analog gap signal 0–10 V Noncontact monitoring

2. Monitoring shaft runout at a metal reference surface

A rotating shaft or metal reference collar can present a qualified target surface to the sensor while external equipment samples the analog voltage. Changes in the calibrated distance relationship reveal local radial movement over a revolution. The acquisition rate and shaft event frequency are selected within the documented sensor bandwidth at its stated reference distance.

Problem Solved

A sampled analog displacement signal lets external analysis distinguish changing radial position over successive revolutions, supporting condition monitoring without a mechanical probe riding on the rotating target surface.

Runout monitoring 1000 Hz bandwidth Analog acquisition

3. Tracking a metal fixture slide through its local stroke

A fixture slide can carry a qualified metal reference feature through the 0–6 mm sensing region near a defined clamping position. The external controller evaluates the analog voltage against calibrated position windows rather than a single presence state. Constant-temperature repeatability provides a documented reference for repeated local position measurements under controlled ambient conditions.

Problem Solved

An analog position window helps external sequence logic distinguish a slide approaching its intended position from one remaining partially displaced, without adding a contact switch at every monitored local position.

Fixture displacement Analog position windows Repeatability