Festo SFAH-0.1U-Q4S-PNLK Air Flow Sensor

USD 266.42

Thermal mass flow transmitter measuring 0.002 to 0.1 L/min. Features a high-visibility multi-color LCD, IO-Link connectivity, and IP40 reinforced PA housing.

SKU Festo-8058462 Category
Top Brands > Festo > Festo Flow Sensors

Festo SFAH-0.1U-Q4S-PNLK Air Flow Sensor

Model Identifier SFAH-0.1U-Q4S-PNLK-PNVBA-M8
Official Part Number 8058462
GTIN Standard 4052568295448

Technical Overview

Thermal mass flow transmitter measuring 0.002 to 0.1 L/min. Features a high-visibility multi-color LCD, IO-Link connectivity, and IP40 reinforced PA housing.

Key Features

  • Thermal measuring principle utilizing heat transfer for accurate mass and volumetric flow rate detection
  • Ultra-low measuring range of 0.002 to 0.1 L/min with unidirectional flow direction
  • Dual programmable digital outputs (PNP/NPN) and one analog output (0-10V / 1-5V / 4-20mA)
  • Built-in IO-Link communication interface for advanced diagnostic and parametrization capabilities
  • Multi-color illuminated LCD display provides immediate visual feedback of flow conditions
  • Compact reinforced polyamide (PA) housing rated to IP40 protection standards
  • Convenient 4 mm push-in pneumatic connections with a standard 4-pin M8 A-coded electrical plug

IO-Link Capable with Multi-Color LCD and Thermal Measurement

Technical Specification Matrix

ParameterValue
Measured VariableMass / Volumetric flow rate
Flow Measuring Range0.002 to 0.1 L/min
Operating Pressure Range-0.9 to 10 bar
Operating Voltage24 VDC nominal (22 to 25.9 VDC)
Output Signals2x Digital (PNP/NPN) + 1x Analog (0-10V / 4-20mA)
Communication InterfaceIO-Link
Pneumatic ConnectionPush-in connector 4 mm (Q4)
Electrical Connection4-pin M8x1 A-coded plug
Medium Temperature0°C to 50°C
Degree of ProtectionIP40
Housing MaterialReinforced Polyamide (PA)
Physical Weight (kg)0.06
Dimensions L x W x H (cm)7 x 2 x 0

Industrial Applications

1. Precise Pick & Place Vacuum Monitoring

Used in conjunction with vacuum grippers handling miniature electronic components, providing micro-flow verification.

Problem Solved

Eliminates false positives by precisely verifying micro-flow blockages (0.002 L/min) indicating a tiny object is firmly secured, rather than relying strictly on macro-level pressure switches.

Vacuum GripperMicro-flow MonitoringObject DetectionPick and Place

2. Micro-Leakage Detection in Assembly Verification

Deployed at the end of manufacturing lines to check micro-leaks in sealed medical devices, pneumatic valves, or cylinders.

Problem Solved

The highly sensitive thermal heat transfer measurement identifies minute air escapes (down to 0.002 L/min) to determine if seals pass stringent quality assurance tests.

Leakage DetectionQuality AssurancePneumatic TestingThermal Heat Transfer

3. Medical & Inert Gas Dosage Control

Real-time verification of trace gas flows for precise mixing or dosing applications within automated laboratory environments.

Problem Solved

The low volumetric range exactly measures ultra-low gas volumes to prevent under-dosing or overdosing in critical protective gas environments.

Gas MixingDosage ControlVolumetric Flow RateInert Gas