EasyPact D3N – LC1N – 3 Poles (3NO) Contactor, 40A – Schneider Contactors & Reversing Contactors

USD $ 26.46USD $ 30.66

SKU: N/A

Specifications

Main
Part Number LC1N40B5N LC1N40CC5N LC1N40E5N
Product Series Compact Compact Compact
product type Contactor Contactor Contactor
product short name LC1N LC1N LC1N
Application field of contactor Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
use category AC-1
AC-4
AC-3
AC-4
AC-3
AC-1
AC-1
AC-4
AC-3
number of poles 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 690 V AC 50/60 Hz Power circuit: <= 690 V AC 50/60 Hz Power circuit: <= 690 V AC 50/60 Hz
Rated operating current [Ie] 40 A 60 °C) at <= 440 V AC AC-3 for power circuit
50 A 60 °C) at <= 440 V AC AC-1 for power circuit
18.5 A 60 °C) at < = 440 V AC AC-4 for power circuits
40 A 60 °C) at <= 440 V AC AC-3 for power circuit
50 A 60 °C) at <= 440 V AC AC-1 for power circuit
18.5 A 60 °C) at < = 440 V AC AC-4 for power circuits
40 A 60 °C) at <= 440 V AC AC-3 for power circuit
50 A 60 °C) at <= 440 V AC AC-1 for power circuit
18.5 A 60 °C) at < = 440 V AC AC-4 for power circuits
[Uc] control circuit voltage 24 V AC 50 Hz 36V AC 50Hz 48V AC 50Hz
Additional information
Motor power (kW) 18.5 kW at 380/400 V AC 50/60 Hz
11 kW at 220/230 V AC 50/60 Hz
22 kW at 415/440 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
30 kW at 660/690 V AC 50/60 Hz
18.5 kW at 380/400 V AC 50/60 Hz
11 kW at 220/230 V AC 50/60 Hz
22 kW at 415/440 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
30 kW at 660/690 V AC 50/60 Hz
18.5 kW at 380/400 V AC 50/60 Hz
11 kW at 220/230 V AC 50/60 Hz
22 kW at 415/440 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
30 kW at 660/690 V AC 50/60 Hz
Loop contact type 3 NO 3 NO 3 NO
Conventional thermal current [Ith] 50 A at <60 °C for power circuits 50 A at <60 °C for power circuits 50 A at <60 °C for power circuits
Rated making capacity [Irms] 400 A at 440 V AC for power circuits according to IEC 60947-4-1
140 A AC for auxiliary contacts according to IEC 60947-5-1
400 A at 440 V AC for power circuits according to IEC 60947-4-1
140 A AC for auxiliary contacts according to IEC 60947-5-1
400 A at 440 V AC for power circuits according to IEC 60947-4-1
140 A AC for auxiliary contacts according to IEC 60947-5-1
Rated breaking capacity 320 A at 440 V for power circuits conforming to IEC 60947 320 A at 440 V for power circuits conforming to IEC 60947 320 A at 440 V for power circuits conforming to IEC 60947
Rated short-time withstand current [Icw] 320 A for power circuits at <40 °C – 10 s
165 A for power circuits at <40 °C – 60 s
72 A for power circuits at <40 °C – 600 s
320 A for power circuits at <40 °C – 10 s
165 A for power circuits at <40 °C – 60 s
72 A for power circuits at <40 °C – 600 s
320 A for power circuits at <40 °C – 10 s
165 A for power circuits at <40 °C – 60 s
72 A for power circuits at <40 °C – 600 s
Fuses for use with relays 10 A gG at <= 690 V with type 1 suitable control circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V with type 1 suitable power circuit
10 A gG at <= 690 V with type 1 suitable control circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V with type 1 suitable power circuit
10 A gG at <= 690 V with type 1 suitable control circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V with type 1 suitable power circuit
average impedance 1.5 mΩ – Ith 60 A 50 Hz for power circuits 1.5 mΩ – Ith 60 A 50 Hz for power circuits 1.5 mΩ – Ith 60 A 50 Hz for power circuits
power consumption per pole 2.4W AC-3
5.4W AC-1
2.4W AC-3
5.4W AC-1
2.4W AC-3
5.4W AC-1
Rated insulation voltage [Ui] 690 V conforming to IEC 60947-4-1 690 V conforming to IEC 60947-4-1 690 V conforming to IEC 60947-4-1
Overvoltage category III III III
pollution level 3 3 3
Rated impulse withstand voltage [Uimp] 6 kV coil not connected to power circuit conforming to IEC 60947 6 kV coil not connected to power circuit conforming to IEC 60947 6 kV coil not connected to power circuit conforming to IEC 60947
Mechanical life 5000000 times 5000000 times 5000000 times
Electrical life 350,000 AC-1
900,000 AC-3
200,000 AC-4
350,000 AC-1
900,000 AC-3
200,000 AC-4
350,000 AC-1
900,000 AC-3
200,000 AC-4
Control loop characteristics AC at 50 Hz AC at 50 Hz AC at 50 Hz
Control voltage limit 0.85…1.1 Uc 55 °C run 50 Hz
0.3…0.6 Uc 55 °C release 50 Hz
0.85…1.1 Uc 55 °C run 50 Hz
0.3…0.6 Uc 55 °C release 50 Hz
0.85…1.1 Uc 55 °C run 50 Hz
0.3…0.6 Uc 55 °C release 50 Hz
(~50Hz pickup) power consumption (VA) 160VA 50Hz (0.75 20°C) 160VA 50Hz (0.75 20°C) 160VA 50Hz (0.75 20°C)
(~50Hz hold) power consumption (VA) 15VA 50Hz 0.3 20°C) 15VA 50Hz 0.3 20°C) 15VA 50Hz 0.3 20°C)
heat dissipation 6…10 W for control circuits 6…10 W for control circuits 6…10 W for control circuits
action time 20…26 ms off
8…12 ms on opening
20…26 ms off
8…12 ms on opening
20…26 ms off
8…12 ms on opening
operating frequency 1200 cycles/h at <55 °C 1200 cycles/h at <55 °C 1200 cycles/h at <55 °C
Wiring capacity Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals
control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal
control circuit: screw-on2 1…4 mm² cable option Type: Solid wire without wire terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Power circuit: Bolt fastened1 2.5…25 mm² Cable selection: Flexible wire with wire Terminals
Power circuit: Bolt-on2 2.5…10 mm² Cable option: flexible with wire terminal
Power circuit: Bolt-on1 2.5…25 mm² Cable option: Solid without wire terminal
Power circuit: Bolt-on 2 2.5…16 mm² Cable option: solid without cable terminals
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals
control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal
control circuit: screw-on2 1…4 mm² cable option Type: Solid wire without wire terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Power circuit: Bolt fastened1 2.5…25 mm² Cable selection: Flexible wire with wire Terminals
Power circuit: Bolt-on2 2.5…10 mm² Cable option: flexible with wire terminal
Power circuit: Bolt-on1 2.5…25 mm² Cable option: Solid without wire terminal
Power circuit: Bolt-on 2 2.5…16 mm² Cable option: solid without cable terminals
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals
control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal
control circuit: screw-on2 1…4 mm² cable option Type: Solid wire without wire terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Power circuit: Bolt fastened1 2.5…25 mm² Cable selection: Flexible wire with wire Terminals
Power circuit: Bolt-on2 2.5…10 mm² Cable option: flexible with wire terminal
Power circuit: Bolt-on1 2.5…25 mm² Cable option: Solid without wire terminal
Power circuit: Bolt-on 2 2.5…16 mm² Cable option: solid without cable terminals
Tightening torque Control circuit: 1.2 Nm
Power circuit: 5 Nm
Control circuit: 1.2 Nm
Power circuit: 5 Nm
Control circuit: 1.2 Nm
Power circuit: 5 Nm
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Minimum switching voltage 17 V for control circuits 17 V for control circuits 17 V for control circuits
Minimum switching current [Imin] 5 mA for control loop 5 mA for control loop 5 mA for control loop
Insulation resistance > 10 MΩ for control loops > 10 MΩ for control loops > 10 MΩ for control loops
non-overlapping time 1.5 ms power-on to ensure NC and NO contact
1.5 ms power-off to ensure NC and NO contact
1.5 ms power-on to ensure NC and NO contact
1.5 ms power-off to ensure NC and NO contact
1.5 ms power-on to ensure NC and NO contact
1.5 ms power-off to ensure NC and NO contact
installation method Chassis mounting
DIN rail mounting
Chassis mounting
DIN rail mounting
Chassis mounting
DIN rail mounting
environment
standard EN 60947-4-1
GB 14048.4
IEC 60947-4-1
EN 60947-1
IEC 60947-1
EN 60947-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
GB 14048.4
GB 14048.4
IEC 60947-1
EN 60947-4-1
IEC 60947-4-1
EN 60947-1
certified product CCC CCC CCC
IP protection class IP20 conforming to IEC 60529 IP20 conforming to IEC 60529 IP20 conforming to IEC 60529
Protective measures TH (pollution degree 3) conforming to IEC 60068 TH (pollution degree 3) conforming to IEC 60068 TH (pollution degree 3) conforming to IEC 60068
ambient air temperature -20…70 °C (allowed at Uc)
-60…80 °C storage
-5…55 °C operation
-20…70 °C (allowed at Uc)
-60…80 °C storage
-5…55 °C operation
-20…70 °C (allowed at Uc)
-60…80 °C storage
-5…55 °C operation
working altitude 3000 m None 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-1 850 °C conforming to IEC 60695-2-1 850 °C conforming to IEC 60695-2-1
Shock and vibration resistance Shock resistance with contacts open (1.5 gn (5…300 Hz))
shock resistance with contacts closed (3 gn (5…300 Hz))
shock resistance with contacts open (6 gn (11ms))
shock resistance Performance Contact closed state (7 gn (11ms))
Shock resistance with contacts open (1.5 gn (5…300 Hz))
shock resistance with contacts closed (3 gn (5…300 Hz))
shock resistance with contacts open (6 gn (11ms))
shock resistance Performance Contact closed state (7 gn (11ms))
Shock resistance with contacts open (1.5 gn (5…300 Hz))
shock resistance with contacts closed (3 gn (5…300 Hz))
shock resistance with contacts open (6 gn (11ms))
shock resistance Performance Contact closed state (7 gn (11ms))
high 127mm 127mm 127mm
width 75 mm 75 mm 75 mm
depth 114 mm 114 mm 114 mm
Product Weight 0.98kg 0.98kg 0.98kg
packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 7.5cm 7.5cm 7.5cm
Package 1 Width 12.7cm 12.7cm 12.7cm
Package 1 Length 11.4 cm 11.4 cm 11.4 cm
Package 1 Weight 981g 981g 981g
contract warranty
Warranty 18 months 18 months 18 months

 

Main
Part Number LC1N40F5N LC1N40M5N LC1N40Q5N
Product Series Compact Compact Compact
product type Contactor Contactor Contactor
product short name LC1N LC1N LC1N
Application field of contactor Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
use category AC-1
AC-3
AC-4
AC-3
AC-4
AC-1
AC-1
AC-4
AC-3
number of poles 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 690 V AC 50/60 Hz Power circuit: <= 690 V AC 50/60 Hz Power circuit: <= 690 V AC 50/60 Hz
Rated operating current [Ie] 40 A 60 °C) at <= 440 V AC AC-3 for power circuit
50 A 60 °C) at <= 440 V AC AC-1 for power circuit
18.5 A 60 °C) at < = 440 V AC AC-4 for power circuits
40 A 60 °C) at <= 440 V AC AC-3 for power circuit
50 A 60 °C) at <= 440 V AC AC-1 for power circuit
18.5 A 60 °C) at < = 440 V AC AC-4 for power circuits
40 A 60 °C) at <= 440 V AC AC-3 for power circuit
50 A 60 °C) at <= 440 V AC AC-1 for power circuit
18.5 A 60 °C) at < = 440 V AC AC-4 for power circuits
[Uc] control circuit voltage 110V AC 50Hz 230V AC 50Hz 380V AC 50Hz
Additional information
Motor power (kW) 18.5 kW at 380/400 V AC 50/60 Hz
11 kW at 220/230 V AC 50/60 Hz
22 kW at 415/440 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
30 kW at 660/690 V AC 50/60 Hz
18.5 kW at 380/400 V AC 50/60 Hz
11 kW at 220/230 V AC 50/60 Hz
22 kW at 415/440 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
30 kW at 660/690 V AC 50/60 Hz
18.5 kW at 380/400 V AC 50/60 Hz
11 kW at 220/230 V AC 50/60 Hz
22 kW at 415/440 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
30 kW at 660/690 V AC 50/60 Hz
Loop contact type 3 NO 3 NO 3 NO
Conventional thermal current [Ith] 50 A at <60 °C for power circuits 50 A at <60 °C for power circuits 50 A at <60 °C for power circuits
Rated making capacity [Irms] 400 A at 440 V AC for power circuits according to IEC 60947-4-1
140 A AC for auxiliary contacts according to IEC 60947-5-1
400 A at 440 V AC for power circuits according to IEC 60947-4-1
140 A AC for auxiliary contacts according to IEC 60947-5-1
400 A at 440 V AC for power circuits according to IEC 60947-4-1
140 A AC for auxiliary contacts according to IEC 60947-5-1
Rated breaking capacity 320 A at 440 V for power circuits conforming to IEC 60947 320 A at 440 V for power circuits conforming to IEC 60947 320 A at 440 V for power circuits conforming to IEC 60947
Rated short-time withstand current [Icw] 320 A for power circuits at <40 °C – 10 s
165 A for power circuits at <40 °C – 60 s
72 A for power circuits at <40 °C – 600 s
320 A for power circuits at <40 °C – 10 s
165 A for power circuits at <40 °C – 60 s
72 A for power circuits at <40 °C – 600 s
320 A for power circuits at <40 °C – 10 s
165 A for power circuits at <40 °C – 60 s
72 A for power circuits at <40 °C – 600 s
Fuses for use with relays 10 A gG at <= 690 V with type 1 suitable control circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V with type 1 suitable power circuit
10 A gG at <= 690 V with type 1 suitable control circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V with type 1 suitable power circuit
10 A gG at <= 690 V with type 1 suitable control circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V with type 1 suitable power circuit
average impedance 1.5 mΩ – Ith 60 A 50 Hz for power circuits 1.5 mΩ – Ith 60 A 50 Hz for power circuits 1.5 mΩ – Ith 60 A 50 Hz for power circuits
power consumption per pole 2.4W AC-3
5.4W AC-1
2.4W AC-3
5.4W AC-1
2.4W AC-3
5.4W AC-1
Rated insulation voltage [Ui] 690 V conforming to IEC 60947-4-1 690 V conforming to IEC 60947-4-1 690 V conforming to IEC 60947-4-1
Overvoltage category III III III
pollution level 3 3 3
Rated impulse withstand voltage [Uimp] 6 kV coil not connected to power circuit conforming to IEC 60947 6 kV coil not connected to power circuit conforming to IEC 60947 6 kV coil not connected to power circuit conforming to IEC 60947
Mechanical life 5000000 times 5000000 times 5000000 times
Electrical life 350,000 AC-1
900,000 AC-3
200,000 AC-4
350,000 AC-1
900,000 AC-3
200,000 AC-4
350,000 AC-1
900,000 AC-3
200,000 AC-4
Control loop characteristics AC at 50 Hz AC at 50 Hz AC at 50 Hz
Control voltage limit 0.85…1.1 Uc 55 °C run 50 Hz
0.3…0.6 Uc 55 °C release 50 Hz
0.85…1.1 Uc 55 °C run 50 Hz
0.3…0.6 Uc 55 °C release 50 Hz
0.85…1.1 Uc 55 °C run 50 Hz
0.3…0.6 Uc 55 °C release 50 Hz
(~50Hz pickup) power consumption (VA) 160VA 50Hz (0.75 20°C) 160VA 50Hz (0.75 20°C) 160VA 50Hz (0.75 20°C)
(~50Hz hold) power consumption (VA) 15VA 50Hz 0.3 20°C) 15VA 50Hz 0.3 20°C) 15VA 50Hz 0.3 20°C)
heat dissipation 6…10 W for control circuits 6…10 W for control circuits 6…10 W for control circuits
action time 20…26 ms off
8…12 ms on opening
20…26 ms off
8…12 ms on opening
20…26 ms off
8…12 ms on opening
operating frequency 1200 cycles/h at <55 °C 1200 cycles/h at <55 °C 1200 cycles/h at <55 °C
Wiring capacity Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals
control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal
control circuit: screw-on2 1…4 mm² cable option Type: Solid wire without wire terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Power circuit: Bolt fastened1 2.5…25 mm² Cable selection: Flexible wire with wire Terminals
Power circuit: Bolt-on2 2.5…10 mm² Cable option: flexible with wire terminal
Power circuit: Bolt-on1 2.5…25 mm² Cable option: Solid without wire terminal
Power circuit: Bolt-on 2 2.5…16 mm² Cable option: solid without cable terminals
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals
control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal
control circuit: screw-on2 1…4 mm² cable option Type: Solid wire without wire terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Power circuit: Bolt fastened1 2.5…25 mm² Cable selection: Flexible wire with wire Terminals
Power circuit: Bolt-on2 2.5…10 mm² Cable option: flexible with wire terminal
Power circuit: Bolt-on1 2.5…25 mm² Cable option: Solid without wire terminal
Power circuit: Bolt-on 2 2.5…16 mm² Cable option: solid without cable terminals
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals
control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal
control circuit: screw-on2 1…4 mm² cable option Type: Solid wire without wire terminal
Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminal
Power circuit: Bolt fastened1 2.5…25 mm² Cable selection: Flexible wire with wire Terminals
Power circuit: Bolt-on2 2.5…10 mm² Cable option: flexible with wire terminal
Power circuit: Bolt-on1 2.5…25 mm² Cable option: Solid without wire terminal
Power circuit: Bolt-on 2 2.5…16 mm² Cable option: solid without cable terminals
Tightening torque Control circuit: 1.2 Nm
Power circuit: 5 Nm
Control circuit: 1.2 Nm
Power circuit: 5 Nm
Control circuit: 1.2 Nm
Power circuit: 5 Nm
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Minimum switching voltage 17 V for control circuits 17 V for control circuits 17 V for control circuits
Minimum switching current [Imin] 5 mA for control loop 5 mA for control loop 5 mA for control loop
Insulation resistance > 10 MΩ for control loops > 10 MΩ for control loops > 10 MΩ for control loops
non-overlapping time 1.5 ms power-on to ensure NC and NO contact
1.5 ms power-off to ensure NC and NO contact
1.5 ms power-on to ensure NC and NO contact
1.5 ms power-off to ensure NC and NO contact
1.5 ms power-on to ensure NC and NO contact
1.5 ms power-off to ensure NC and NO contact
installation method Chassis mounting
DIN rail mounting
Chassis mounting
DIN rail mounting
Chassis mounting
DIN rail mounting
environment
standard IEC 60947-1
IEC 60947-4-1
EN 60947-4-1
GB 14048.4
EN 60947-1
GB 14048.4
EN 60947-1
EN 60947-4-1
IEC 60947-4-1
IEC 60947-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
EN 60947-1
GB 14048.4
certified product CCC CCC CCC
IP protection class IP20 conforming to IEC 60529 IP20 conforming to IEC 60529 IP20 conforming to IEC 60529
Protective measures TH (pollution degree 3) conforming to IEC 60068 TH (pollution degree 3) conforming to IEC 60068 TH (pollution degree 3) conforming to IEC 60068
ambient air temperature -20…70 °C (allowed at Uc)
-60…80 °C storage
-5…55 °C operation
-20…70 °C (allowed at Uc)
-60…80 °C storage
-5…55 °C operation
-20…70 °C (allowed at Uc)
-60…80 °C storage
-5…55 °C operation
working altitude 3000 m None 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-1 850 °C conforming to IEC 60695-2-1 850 °C conforming to IEC 60695-2-1
Shock and vibration resistance Shock resistance with contacts open (1.5 gn (5…300 Hz))
shock resistance with contacts closed (3 gn (5…300 Hz))
shock resistance with contacts open (6 gn (11ms))
shock resistance Performance Contact closed state (7 gn (11ms))
Shock resistance with contacts open (1.5 gn (5…300 Hz))
shock resistance with contacts closed (3 gn (5…300 Hz))
shock resistance with contacts open (6 gn (11ms))
shock resistance Performance Contact closed state (7 gn (11ms))
Shock resistance with contacts open (1.5 gn (5…300 Hz))
shock resistance with contacts closed (3 gn (5…300 Hz))
shock resistance with contacts open (6 gn (11ms))
shock resistance Performance Contact closed state (7 gn (11ms))
high 127mm 127mm 127mm
width 75 mm 75 mm 75 mm
depth 114 mm 114 mm 114 mm
Product Weight 0.98kg 0.98kg 0.98kg
packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 7.5cm 8.309 cm 7.5cm
Package 1 Width 12.7cm 12.365 cm 12.7cm
Package 1 Length 11.4 cm 13.151 cm 11.4 cm
Package 1 Weight 981g 981g 981g
contract warranty
Warranty 18 months 18 months 18 months

 

Weight N/A
Dimensions N/A