$ 28.98 – $ 33.58
Main | |||
Part Number | LC1N40B5N | LC1N40CC5N | LC1N40E5N |
Product Series | Compact | Compact | Compact |
product type | Contactor | Contactor | Contactor |
product short name | LC1N | LC1N | LC1N |
Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
use category | AC-1 AC-4 AC-3 |
AC-4 AC-3 AC-1 |
AC-1 AC-4 AC-3 |
number of poles | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 50/60 Hz | Power circuit: <= 690 V AC 50/60 Hz | Power circuit: <= 690 V AC 50/60 Hz |
Rated operating current [Ie] | 40 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 18.5 A 60 °C) at < = 440 V AC AC-4 for power circuits |
40 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 18.5 A 60 °C) at < = 440 V AC AC-4 for power circuits |
40 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 18.5 A 60 °C) at < = 440 V AC AC-4 for power circuits |
[Uc] control circuit voltage | 24 V AC 50 Hz | 36V AC 50Hz | 48V AC 50Hz |
Additional information | |||
Motor power (kW) | 18.5 kW at 380/400 V AC 50/60 Hz 11 kW at 220/230 V AC 50/60 Hz 22 kW at 415/440 V AC 50/60 Hz 22 kW at 500 V AC 50/60 Hz 30 kW at 660/690 V AC 50/60 Hz |
18.5 kW at 380/400 V AC 50/60 Hz 11 kW at 220/230 V AC 50/60 Hz 22 kW at 415/440 V AC 50/60 Hz 22 kW at 500 V AC 50/60 Hz 30 kW at 660/690 V AC 50/60 Hz |
18.5 kW at 380/400 V AC 50/60 Hz 11 kW at 220/230 V AC 50/60 Hz 22 kW at 415/440 V AC 50/60 Hz 22 kW at 500 V AC 50/60 Hz 30 kW at 660/690 V AC 50/60 Hz |
Loop contact type | 3 NO | 3 NO | 3 NO |
Conventional thermal current [Ith] | 50 A at <60 °C for power circuits | 50 A at <60 °C for power circuits | 50 A at <60 °C for power circuits |
Rated making capacity [Irms] | 400 A at 440 V AC for power circuits according to IEC 60947-4-1 140 A AC for auxiliary contacts according to IEC 60947-5-1 |
400 A at 440 V AC for power circuits according to IEC 60947-4-1 140 A AC for auxiliary contacts according to IEC 60947-5-1 |
400 A at 440 V AC for power circuits according to IEC 60947-4-1 140 A AC for auxiliary contacts according to IEC 60947-5-1 |
Rated breaking capacity | 320 A at 440 V for power circuits conforming to IEC 60947 | 320 A at 440 V for power circuits conforming to IEC 60947 | 320 A at 440 V for power circuits conforming to IEC 60947 |
Rated short-time withstand current [Icw] | 320 A for power circuits at <40 °C – 10 s 165 A for power circuits at <40 °C – 60 s 72 A for power circuits at <40 °C – 600 s |
320 A for power circuits at <40 °C – 10 s 165 A for power circuits at <40 °C – 60 s 72 A for power circuits at <40 °C – 600 s |
320 A for power circuits at <40 °C – 10 s 165 A for power circuits at <40 °C – 60 s 72 A for power circuits at <40 °C – 600 s |
Fuses for use with relays | 10 A gG at <= 690 V with type 1 suitable control circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V with type 1 suitable power circuit |
10 A gG at <= 690 V with type 1 suitable control circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V with type 1 suitable power circuit |
10 A gG at <= 690 V with type 1 suitable control circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V with type 1 suitable power circuit |
average impedance | 1.5 mΩ – Ith 60 A 50 Hz for power circuits | 1.5 mΩ – Ith 60 A 50 Hz for power circuits | 1.5 mΩ – Ith 60 A 50 Hz for power circuits |
power consumption per pole | 2.4W AC-3 5.4W AC-1 |
2.4W AC-3 5.4W AC-1 |
2.4W AC-3 5.4W AC-1 |
Rated insulation voltage [Ui] | 690 V conforming to IEC 60947-4-1 | 690 V conforming to IEC 60947-4-1 | 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III | III | III |
pollution level | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV coil not connected to power circuit conforming to IEC 60947 | 6 kV coil not connected to power circuit conforming to IEC 60947 | 6 kV coil not connected to power circuit conforming to IEC 60947 |
Mechanical life | 5000000 times | 5000000 times | 5000000 times |
Electrical life | 350,000 AC-1 900,000 AC-3 200,000 AC-4 |
350,000 AC-1 900,000 AC-3 200,000 AC-4 |
350,000 AC-1 900,000 AC-3 200,000 AC-4 |
Control loop characteristics | AC at 50 Hz | AC at 50 Hz | AC at 50 Hz |
Control voltage limit | 0.85…1.1 Uc 55 °C run 50 Hz 0.3…0.6 Uc 55 °C release 50 Hz |
0.85…1.1 Uc 55 °C run 50 Hz 0.3…0.6 Uc 55 °C release 50 Hz |
0.85…1.1 Uc 55 °C run 50 Hz 0.3…0.6 Uc 55 °C release 50 Hz |
(~50Hz pickup) power consumption (VA) | 160VA 50Hz (0.75 20°C) | 160VA 50Hz (0.75 20°C) | 160VA 50Hz (0.75 20°C) |
(~50Hz hold) power consumption (VA) | 15VA 50Hz 0.3 20°C) | 15VA 50Hz 0.3 20°C) | 15VA 50Hz 0.3 20°C) |
heat dissipation | 6…10 W for control circuits | 6…10 W for control circuits | 6…10 W for control circuits |
action time | 20…26 ms off 8…12 ms on opening |
20…26 ms off 8…12 ms on opening |
20…26 ms off 8…12 ms on opening |
operating frequency | 1200 cycles/h at <55 °C | 1200 cycles/h at <55 °C | 1200 cycles/h at <55 °C |
Wiring capacity | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid wire without wire terminal Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminal Power circuit: Bolt fastened1 2.5…25 mm² Cable selection: Flexible wire with wire Terminals Power circuit: Bolt-on2 2.5…10 mm² Cable option: flexible with wire terminal Power circuit: Bolt-on1 2.5…25 mm² Cable option: Solid without wire terminal Power circuit: Bolt-on 2 2.5…16 mm² Cable option: solid without cable terminals |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid wire without wire terminal Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminal Power circuit: Bolt fastened1 2.5…25 mm² Cable selection: Flexible wire with wire Terminals Power circuit: Bolt-on2 2.5…10 mm² Cable option: flexible with wire terminal Power circuit: Bolt-on1 2.5…25 mm² Cable option: Solid without wire terminal Power circuit: Bolt-on 2 2.5…16 mm² Cable option: solid without cable terminals |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid wire without wire terminal Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminal Power circuit: Bolt fastened1 2.5…25 mm² Cable selection: Flexible wire with wire Terminals Power circuit: Bolt-on2 2.5…10 mm² Cable option: flexible with wire terminal Power circuit: Bolt-on1 2.5…25 mm² Cable option: Solid without wire terminal Power circuit: Bolt-on 2 2.5…16 mm² Cable option: solid without cable terminals |
Tightening torque | Control circuit: 1.2 Nm Power circuit: 5 Nm |
Control circuit: 1.2 Nm Power circuit: 5 Nm |
Control circuit: 1.2 Nm Power circuit: 5 Nm |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Minimum switching voltage | 17 V for control circuits | 17 V for control circuits | 17 V for control circuits |
Minimum switching current [Imin] | 5 mA for control loop | 5 mA for control loop | 5 mA for control loop |
Insulation resistance | > 10 MΩ for control loops | > 10 MΩ for control loops | > 10 MΩ for control loops |
non-overlapping time | 1.5 ms power-on to ensure NC and NO contact 1.5 ms power-off to ensure NC and NO contact |
1.5 ms power-on to ensure NC and NO contact 1.5 ms power-off to ensure NC and NO contact |
1.5 ms power-on to ensure NC and NO contact 1.5 ms power-off to ensure NC and NO contact |
installation method | Chassis mounting DIN rail mounting |
Chassis mounting DIN rail mounting |
Chassis mounting DIN rail mounting |
environment | |||
standard | EN 60947-4-1 GB 14048.4 IEC 60947-4-1 EN 60947-1 IEC 60947-1 |
EN 60947-1 IEC 60947-4-1 IEC 60947-1 EN 60947-4-1 GB 14048.4 |
GB 14048.4 IEC 60947-1 EN 60947-4-1 IEC 60947-4-1 EN 60947-1 |
certified product | CCC | CCC | CCC |
IP protection class | IP20 conforming to IEC 60529 | IP20 conforming to IEC 60529 | IP20 conforming to IEC 60529 |
Protective measures | TH (pollution degree 3) conforming to IEC 60068 | TH (pollution degree 3) conforming to IEC 60068 | TH (pollution degree 3) conforming to IEC 60068 |
ambient air temperature | -20…70 °C (allowed at Uc) -60…80 °C storage -5…55 °C operation |
-20…70 °C (allowed at Uc) -60…80 °C storage -5…55 °C operation |
-20…70 °C (allowed at Uc) -60…80 °C storage -5…55 °C operation |
working altitude | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-1 | 850 °C conforming to IEC 60695-2-1 | 850 °C conforming to IEC 60695-2-1 |
Shock and vibration resistance | Shock resistance with contacts open (1.5 gn (5…300 Hz)) shock resistance with contacts closed (3 gn (5…300 Hz)) shock resistance with contacts open (6 gn (11ms)) shock resistance Performance Contact closed state (7 gn (11ms)) |
Shock resistance with contacts open (1.5 gn (5…300 Hz)) shock resistance with contacts closed (3 gn (5…300 Hz)) shock resistance with contacts open (6 gn (11ms)) shock resistance Performance Contact closed state (7 gn (11ms)) |
Shock resistance with contacts open (1.5 gn (5…300 Hz)) shock resistance with contacts closed (3 gn (5…300 Hz)) shock resistance with contacts open (6 gn (11ms)) shock resistance Performance Contact closed state (7 gn (11ms)) |
high | 127mm | 127mm | 127mm |
width | 75 mm | 75 mm | 75 mm |
depth | 114 mm | 114 mm | 114 mm |
Product Weight | 0.98kg | 0.98kg | 0.98kg |
packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 7.5cm | 7.5cm | 7.5cm |
Package 1 Width | 12.7cm | 12.7cm | 12.7cm |
Package 1 Length | 11.4 cm | 11.4 cm | 11.4 cm |
Package 1 Weight | 981g | 981g | 981g |
contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Main | |||
Part Number | LC1N40F5N | LC1N40M5N | LC1N40Q5N |
Product Series | Compact | Compact | Compact |
product type | Contactor | Contactor | Contactor |
product short name | LC1N | LC1N | LC1N |
Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
use category | AC-1 AC-3 AC-4 |
AC-3 AC-4 AC-1 |
AC-1 AC-4 AC-3 |
number of poles | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 50/60 Hz | Power circuit: <= 690 V AC 50/60 Hz | Power circuit: <= 690 V AC 50/60 Hz |
Rated operating current [Ie] | 40 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 18.5 A 60 °C) at < = 440 V AC AC-4 for power circuits |
40 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 18.5 A 60 °C) at < = 440 V AC AC-4 for power circuits |
40 A 60 °C) at <= 440 V AC AC-3 for power circuit 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 18.5 A 60 °C) at < = 440 V AC AC-4 for power circuits |
[Uc] control circuit voltage | 110V AC 50Hz | 230V AC 50Hz | 380V AC 50Hz |
Additional information | |||
Motor power (kW) | 18.5 kW at 380/400 V AC 50/60 Hz 11 kW at 220/230 V AC 50/60 Hz 22 kW at 415/440 V AC 50/60 Hz 22 kW at 500 V AC 50/60 Hz 30 kW at 660/690 V AC 50/60 Hz |
18.5 kW at 380/400 V AC 50/60 Hz 11 kW at 220/230 V AC 50/60 Hz 22 kW at 415/440 V AC 50/60 Hz 22 kW at 500 V AC 50/60 Hz 30 kW at 660/690 V AC 50/60 Hz |
18.5 kW at 380/400 V AC 50/60 Hz 11 kW at 220/230 V AC 50/60 Hz 22 kW at 415/440 V AC 50/60 Hz 22 kW at 500 V AC 50/60 Hz 30 kW at 660/690 V AC 50/60 Hz |
Loop contact type | 3 NO | 3 NO | 3 NO |
Conventional thermal current [Ith] | 50 A at <60 °C for power circuits | 50 A at <60 °C for power circuits | 50 A at <60 °C for power circuits |
Rated making capacity [Irms] | 400 A at 440 V AC for power circuits according to IEC 60947-4-1 140 A AC for auxiliary contacts according to IEC 60947-5-1 |
400 A at 440 V AC for power circuits according to IEC 60947-4-1 140 A AC for auxiliary contacts according to IEC 60947-5-1 |
400 A at 440 V AC for power circuits according to IEC 60947-4-1 140 A AC for auxiliary contacts according to IEC 60947-5-1 |
Rated breaking capacity | 320 A at 440 V for power circuits conforming to IEC 60947 | 320 A at 440 V for power circuits conforming to IEC 60947 | 320 A at 440 V for power circuits conforming to IEC 60947 |
Rated short-time withstand current [Icw] | 320 A for power circuits at <40 °C – 10 s 165 A for power circuits at <40 °C – 60 s 72 A for power circuits at <40 °C – 600 s |
320 A for power circuits at <40 °C – 10 s 165 A for power circuits at <40 °C – 60 s 72 A for power circuits at <40 °C – 600 s |
320 A for power circuits at <40 °C – 10 s 165 A for power circuits at <40 °C – 60 s 72 A for power circuits at <40 °C – 600 s |
Fuses for use with relays | 10 A gG at <= 690 V with type 1 suitable control circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V with type 1 suitable power circuit |
10 A gG at <= 690 V with type 1 suitable control circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V with type 1 suitable power circuit |
10 A gG at <= 690 V with type 1 suitable control circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V with type 1 suitable power circuit |
average impedance | 1.5 mΩ – Ith 60 A 50 Hz for power circuits | 1.5 mΩ – Ith 60 A 50 Hz for power circuits | 1.5 mΩ – Ith 60 A 50 Hz for power circuits |
power consumption per pole | 2.4W AC-3 5.4W AC-1 |
2.4W AC-3 5.4W AC-1 |
2.4W AC-3 5.4W AC-1 |
Rated insulation voltage [Ui] | 690 V conforming to IEC 60947-4-1 | 690 V conforming to IEC 60947-4-1 | 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III | III | III |
pollution level | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV coil not connected to power circuit conforming to IEC 60947 | 6 kV coil not connected to power circuit conforming to IEC 60947 | 6 kV coil not connected to power circuit conforming to IEC 60947 |
Mechanical life | 5000000 times | 5000000 times | 5000000 times |
Electrical life | 350,000 AC-1 900,000 AC-3 200,000 AC-4 |
350,000 AC-1 900,000 AC-3 200,000 AC-4 |
350,000 AC-1 900,000 AC-3 200,000 AC-4 |
Control loop characteristics | AC at 50 Hz | AC at 50 Hz | AC at 50 Hz |
Control voltage limit | 0.85…1.1 Uc 55 °C run 50 Hz 0.3…0.6 Uc 55 °C release 50 Hz |
0.85…1.1 Uc 55 °C run 50 Hz 0.3…0.6 Uc 55 °C release 50 Hz |
0.85…1.1 Uc 55 °C run 50 Hz 0.3…0.6 Uc 55 °C release 50 Hz |
(~50Hz pickup) power consumption (VA) | 160VA 50Hz (0.75 20°C) | 160VA 50Hz (0.75 20°C) | 160VA 50Hz (0.75 20°C) |
(~50Hz hold) power consumption (VA) | 15VA 50Hz 0.3 20°C) | 15VA 50Hz 0.3 20°C) | 15VA 50Hz 0.3 20°C) |
heat dissipation | 6…10 W for control circuits | 6…10 W for control circuits | 6…10 W for control circuits |
action time | 20…26 ms off 8…12 ms on opening |
20…26 ms off 8…12 ms on opening |
20…26 ms off 8…12 ms on opening |
operating frequency | 1200 cycles/h at <55 °C | 1200 cycles/h at <55 °C | 1200 cycles/h at <55 °C |
Wiring capacity | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid wire without wire terminal Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminal Power circuit: Bolt fastened1 2.5…25 mm² Cable selection: Flexible wire with wire Terminals Power circuit: Bolt-on2 2.5…10 mm² Cable option: flexible with wire terminal Power circuit: Bolt-on1 2.5…25 mm² Cable option: Solid without wire terminal Power circuit: Bolt-on 2 2.5…16 mm² Cable option: solid without cable terminals |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid wire without wire terminal Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminal Power circuit: Bolt fastened1 2.5…25 mm² Cable selection: Flexible wire with wire Terminals Power circuit: Bolt-on2 2.5…10 mm² Cable option: flexible with wire terminal Power circuit: Bolt-on1 2.5…25 mm² Cable option: Solid without wire terminal Power circuit: Bolt-on 2 2.5…16 mm² Cable option: solid without cable terminals |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid wire without wire terminal Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminal Power circuit: Bolt fastened1 2.5…25 mm² Cable selection: Flexible wire with wire Terminals Power circuit: Bolt-on2 2.5…10 mm² Cable option: flexible with wire terminal Power circuit: Bolt-on1 2.5…25 mm² Cable option: Solid without wire terminal Power circuit: Bolt-on 2 2.5…16 mm² Cable option: solid without cable terminals |
Tightening torque | Control circuit: 1.2 Nm Power circuit: 5 Nm |
Control circuit: 1.2 Nm Power circuit: 5 Nm |
Control circuit: 1.2 Nm Power circuit: 5 Nm |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Minimum switching voltage | 17 V for control circuits | 17 V for control circuits | 17 V for control circuits |
Minimum switching current [Imin] | 5 mA for control loop | 5 mA for control loop | 5 mA for control loop |
Insulation resistance | > 10 MΩ for control loops | > 10 MΩ for control loops | > 10 MΩ for control loops |
non-overlapping time | 1.5 ms power-on to ensure NC and NO contact 1.5 ms power-off to ensure NC and NO contact |
1.5 ms power-on to ensure NC and NO contact 1.5 ms power-off to ensure NC and NO contact |
1.5 ms power-on to ensure NC and NO contact 1.5 ms power-off to ensure NC and NO contact |
installation method | Chassis mounting DIN rail mounting |
Chassis mounting DIN rail mounting |
Chassis mounting DIN rail mounting |
environment | |||
standard | IEC 60947-1 IEC 60947-4-1 EN 60947-4-1 GB 14048.4 EN 60947-1 |
GB 14048.4 EN 60947-1 EN 60947-4-1 IEC 60947-4-1 IEC 60947-1 |
IEC 60947-4-1 IEC 60947-1 EN 60947-4-1 EN 60947-1 GB 14048.4 |
certified product | CCC | CCC | CCC |
IP protection class | IP20 conforming to IEC 60529 | IP20 conforming to IEC 60529 | IP20 conforming to IEC 60529 |
Protective measures | TH (pollution degree 3) conforming to IEC 60068 | TH (pollution degree 3) conforming to IEC 60068 | TH (pollution degree 3) conforming to IEC 60068 |
ambient air temperature | -20…70 °C (allowed at Uc) -60…80 °C storage -5…55 °C operation |
-20…70 °C (allowed at Uc) -60…80 °C storage -5…55 °C operation |
-20…70 °C (allowed at Uc) -60…80 °C storage -5…55 °C operation |
working altitude | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-1 | 850 °C conforming to IEC 60695-2-1 | 850 °C conforming to IEC 60695-2-1 |
Shock and vibration resistance | Shock resistance with contacts open (1.5 gn (5…300 Hz)) shock resistance with contacts closed (3 gn (5…300 Hz)) shock resistance with contacts open (6 gn (11ms)) shock resistance Performance Contact closed state (7 gn (11ms)) |
Shock resistance with contacts open (1.5 gn (5…300 Hz)) shock resistance with contacts closed (3 gn (5…300 Hz)) shock resistance with contacts open (6 gn (11ms)) shock resistance Performance Contact closed state (7 gn (11ms)) |
Shock resistance with contacts open (1.5 gn (5…300 Hz)) shock resistance with contacts closed (3 gn (5…300 Hz)) shock resistance with contacts open (6 gn (11ms)) shock resistance Performance Contact closed state (7 gn (11ms)) |
high | 127mm | 127mm | 127mm |
width | 75 mm | 75 mm | 75 mm |
depth | 114 mm | 114 mm | 114 mm |
Product Weight | 0.98kg | 0.98kg | 0.98kg |
packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 7.5cm | 8.309 cm | 7.5cm |
Package 1 Width | 12.7cm | 12.365 cm | 12.7cm |
Package 1 Length | 11.4 cm | 13.151 cm | 11.4 cm |
Package 1 Weight | 981g | 981g | 981g |
contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,