DT500-A111 Long Range Distance Sensors – SICK Sensor

USD $ 2,487.66

SKU: N/A

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1026515
Distance Sensor Model:DT500-A111
OEM Spec Ref 

Mechanics/electronics

Supply voltage Vs DC 10 V … 30 V, reverse polarity protected

UV ≥ DC 24 V for devices with heating

Ripple 5 Vpp 1)
Power consumption Typ. 3 W
Initialization time 500 ms
Housing material Metal (Aluminum die cast)
Window material Glass
Connection type Male connector, M12, 5-pin
Weight 1,000 g
Dimensions (W x H x D) 69 mm x 50 mm x 153 mm
Enclosure rating IP65
Protection class II 2)
  • 1) May not fall short of or exceed VS tolerances.
  • 2) Reference voltage DC 32 V.

Performance

Measuring range 0.2 m … 30 m, 90 % remission 1) 2)

0.8 m … 15 m, 6 % remission 1) 2)

Target Natural objects
Resolution 12 bit
Repeatability 1 mm 3) 4)
Accuracy ± 3 mm
Response time 250 ms
Output time 250 ms
Light source Laser, red 5)
visible red light
Laser class 2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014)
Typ. light spot size (distance) 10 mm (at 7 m)

45 mm (at 30 m)

100 mm (at 70 m)

  • 1) In ambient light, max. 1 klx of constant light.
  • 2) Unique up to 150 m.
  • 3) 6 % … 90 % remission.
  • 4) Statistical error 1 σ.
  • 5) Average service life of 50,000 h at TA = +25 °C.

Interfaces

Analog output
Number 1
Type Current output
Current 0 mA … 20 mA 1)
Multifunctional input (MF) > 12 V 2)
Laser-off input > 12 V
  • 1) Can be configured to the device: 0 mA … 20 mA / 4 mA … 20 mA (max. load resistance = Uv-2 V / 0.0205 A).
  • 2) Refer to function MF input.

Ambient data

Electromagnetic compatibility (EMC) EN 61000-6-2, EN 55011

EN 60947-5-7: 2003-9

Ambient temperature, operation –10 °C … +45 °C

–10 °C … +75 °C, operation with cooling case

Ambient temperature, storage –25 °C … +75 °C
Temperature drift Typ. 0.05 mm/K
Typ. Ambient light immunity ≤ 3,000 lx
Mechanical load Shock: (EN 600 68-2-27 / –2-29)

Sine: (EN 600 68-2-6)

Noise: (EN 600 68-2-64)