Technical Overview
The SICK DT50-P2123 measures distance to natural objects using a class 1 visible-red time-of-flight laser. Its range is 200–13,000 mm at 90% remission, 200–5,800 mm at 18% and 200–3,400 mm at 6%. One PNP output provides a switching condition and one 4–20 mA output provides a distance-related signal with 16-bit output resolution. Teaching, scaling and inversion apply to both outputs. Fast, medium and slow averaging give 15, 30 or 80 ms lateral-entry response, while continuous distance change has output time ≥2 ms. The IP65 zinc die-cast sensor has an LC display, two LEDs, a five-pin M12 connector and warm-up time up to 15 minutes.
Class 1 red laser distance sensor with target-dependent 200–13,000 mm range, one PNP output, one 4–20 mA output and fast/medium/slow averaging.
Key Features
- 200–13,000 mm at 90% remission; 200–5,800 mm at 18%; 200–3,400 mm at 6%
- 658 nm class 1 visible red laser; typical 15 × 15 mm spot at 10 m
- One PNP switching output, ≤100 mA, short-circuit protected
- One 4–20 mA analog output; load ≤300 Ω; 16-bit output resolution
- Teach-in, scaling and inversion of digital and analog outputs
- Fast / medium / slow averaging; 15 / 30 / 80 ms lateral-entry response
- Output time ≥2 ms for continuous distance change
- Distance-to-object switching; 10–1,000 mm hysteresis; multifunction laser-off/external-teach input
- 10–30 V DC; ≤2.1 W without load; M12 five-pin connection
- IP65 zinc die-cast housing; PMMA window; LC display and two LEDs
Transmit a distance-related current signal and a taught switching condition to external control, checking target remission, timing and analog load.
Technical Specification Matrix
| Parameter | Value |
| Functional principle | Time-of-flight laser distance measurement to natural objects |
| Measuring range | 200–13,000 mm at 90% remission; 200–5,800 mm at 18%; 200–3,400 mm at 6% |
| Resolution | 1,000 µm |
| Repeatability | ≥1 mm, equivalent to 1σ; 6–90% remission; depends on averaging setting |
| Measurement accuracy | ±7 mm at 90% remission |
| Averaging | Fast / medium / slow |
| Response time | 15 / 30 / 80 ms according to averaging; lateral object entry |
| Output time | ≥2 ms for continuous distance change within measuring range |
| Light source | Visible red laser; 658 nm |
| Laser class | 1; IEC 60825-1:2014 and EN 60825-1:2014 |
| Laser pulse figures | Maximum output 120 mW; pulse duration 2.5 ns; duty cycle 1/400 |
| Typical light spot | 15 × 15 mm at 10 m |
| Average laser service life | 100,000 h at +25 °C |
| Digital output | One PNP output; ≤100 mA; Q short-circuit protected |
| Signal voltage HIGH/LOW | PNP: Vs−(<2.5 V) / 0 V |
| Analog output | One 4–20 mA current output; load ≤300 Ω; 16-bit output resolution |
| Output adjustment | Teach-in, scaling and inversion of digital and analog outputs |
| Switching mode | Distance to object, DtO |
| Hysteresis | 10–1,000 mm |
| Multifunction input | Laser off / external teach / deactivated; input response ≤15 ms; HIGH=Vs, LOW≤2.5 V |
| Other functions | Switch off display; reset to factory default; lock user interface |
| Power supply | 10–30 V DC, limit values; reverse-polarity protected; short-circuit-protected network maximum 8 A |
| Power consumption | ≤2.1 W without load |
| Ripple | ≤5 Vpp; remain within supply tolerances |
| Initialization time | ≤250 ms |
| Warm-up time | ≤15 min |
| Display and indicators | LC display; two LEDs; orange Q1 indicator and green supply-active indicator |
| Connection | M12 five-pin male connector |
| Pin assignment | 1 BN=L+; 2 WH=QA analog; 3 BU=M; 4 BK=Q digital; 5 GY=MF |
| Housing material | Zinc die-cast metal |
| Window material | PMMA plastic |
| Mounting holes | Ø4.5 mm |
| IP rating | IP65 |
| Protection class | III |
| Operating temperature | −30 to +65 °C normally; −30 to +80 °C with two cooling plates; −30 to +140 °C with two cooling plates and protection filter |
| Storage temperature | −40 to +75 °C |
| Relative humidity | ≤95%, noncondensing |
| Typical ambient-light immunity | 40,000 lx |
| Vibration resistance | EN 60068-2-6 and EN 60068-2-64 |
| Shock resistance | EN 60068-2-27 |
| MTTFD | 101 years |
| DCavg | 0% |
| Physical Weight (kg) | 0.2 |
| Dimensions L x W x H (cm) | 5.77 × 3.61 × 7.27 |
Industrial Applications
1. Following a material-loop distance
A material loop can present a suitable surface within the laser’s target-dependent measuring range. The 4–20 mA output supplies a distance-related signal to an external controller, which determines how the measured position affects feed motion. Setup establishes output scale, verifies target remission and spot placement, and selects averaging to match the required response and acceptable reading variation.
Problem Solved
A continuous distance reference helps external feed-control logic monitor a material loop, with scaling and averaging chosen for the actual target and process dynamics.
Material loop
Analog distance
External feed control
2. Checking a presented load against a distance threshold
An inspection station can present a load surface within the verified measuring range and teach a PNP switching threshold for the expected position. External logic samples the output during the presentation window. Commissioning checks actual surface remission, distance accuracy, hysteresis and selected averaging so variations in the load and its presentation remain compatible with the required decision margin.
Problem Solved
A taught distance condition helps external inspection logic check a load position, supporting an ordinary process decision after target variation and measurement uncertainty are assessed.
Load position
PNP threshold
Distance inspection
3. Teaching a distance signal after a format change
A machine can present reference positions for a changed format and use the available teach-in, scaling and inversion functions to configure its analog and digital distance signals. External setup logic may use the multifunction input for teaching or laser-off behavior. Commissioning verifies the resulting output scale, switching condition and selected response mode before returning to ordinary production.
Problem Solved
Teach-in and output adjustment help commissioning staff establish distance signals for a changed format, reducing dependence on settings that were chosen for a different target position.
Format setup
Output teaching
Multifunction input