| Functional principle | Laser triangulation distance/displacement measurement |
| Measuring range | 100–1,000 mm; 6–90% remission |
| Resolution | <1 mm; 6–90% remission |
| Repeatability | ≥2.5 mm; 6–90% remission; depends on averaging or sensitivity; regular calibration in application |
| Repeatability by averaging | 10/5/2.5 mm for Fast/Medium/Slow; 6–90% remission, regular calibration in application |
| Linearity | ±6 mm; 90% remission, regular calibration in application |
| Response time | Datasheet lower bound ≥2.5 ms, dependent on averaging/sensitivity; 2.5/10/40 ms for Fast/Medium/Slow with continuous distance changes; lateral target entry ≤22 ms |
| Measuring frequency | ≤400 Hz; 6–90% remission |
| Output time | Datasheet ≥2.5 ms; operating manual specifies <2.8 ms |
| Light source | Visible red laser |
| Laser class | 2; IEC 60825-1:2014, EN 60825-1:2014 |
| Light spot size | Typically 6 × 12 mm at 1,000 mm |
| Digital output | One PNP output; maximum ≤100 mA; HIGH=Vs−(<2 V), LOW=<2 V |
| Analog output | One separate 4–20 mA current output; maximum load ≤300 Ω |
| Analog output resolution | 12 bit |
| Analog span | Teach-in or manual adjustment of 4 mA and 20 mA distance limits; minimum span >1/64 of measuring range; inversion through automatic teach-in |
| Switching mode | Distance to Object (DtO); taught or manually adjusted switching threshold; invertible output |
| Switching hysteresis | 1/16 of measuring range; not adjustable |
| Averaging | Fast / Medium / Slow |
| Multifunction input | One PNP input; HIGH=Vs, LOW≤2 V; laser off, external teach-in or deactivated |
| External teach timing | MF active: >70 and <130 ms for 4 mA; >160 and <230 ms for 20 mA; >260 and <330 ms for Q; >360 and <430 ms for inverted Q |
| Display | LC display and two LEDs: power green, digital output orange; measured distance or menu; NoDist outside measuring range |
| Adjustment | Local keys; display off, reset and user-interface lock |
| Power supply | 10–30 V DC; reverse-polarity protected; short-circuit protected network, maximum 8 A |
| Power consumption | ≤1.8 W without load |
| Residual ripple | ≤5 Vpp; remain within supply voltage limits |
| Initialization time | ≤650 ms |
| Warm-up time | ≤10 min |
| Connection | Turnable male M12 five-pin connector |
| Pin assignment | 1 BN=L+; 4 BK=Q PNP; 3 BU=M; 2 WH=QA current output; 5 GY=MF input |
| Mounting | Ø4.5 mm fixing hole and slot; preferred orientation as shown in manufacturer mounting guide |
| Housing material | Zinc diecast metal |
| Window material | PMMA plastic |
| IP rating | IP65 (EN 60529) |
| Protection class | II |
| Operating temperature | −20 to +55 °C at supply 24 V |
| Storage temperature | −20 to +60 °C |
| Temperature drift | 0.25 mm/K; 0.5 mm/K for distances >600 mm |
| Ambient light immunity | Artificial light ≤3,000 lx; sunlight ≤10,000 lx |
| Vibration resistance | EN 60068-2-6, EN 60068-2-64 |
| Shock resistance | EN 60068-2-27 |
| Physical Weight (kg) | 0.135 |
| Performance below 600 mm | Meets the 100–600 mm model specifications at distances <600 mm: resolution <0.5 mm, repeatability 2/1/0.5 mm (Fast/Medium/Slow), linearity ±2 mm at 90% remission; regular calibration required |
| MTTFD | 101 years |
| DCavg | 0% |