Skip to content

Contact Us:
sales@inosaki.com

SICK 1040140 DT20-N214B Laser Distance Sensor

SICK 1040140 DT20-N214B Laser Distance Sensor

USD 1,004.90

DT20-N214B measures 100–600 mm at 6–90% remission, with a Class 2 red laser, one NPN output, 4–20 mA feedback, LC display and M12 connection.

SKU: SICK-1040140 Category:
Laser Distance Sensors - SICK DT20 Hi

SICK DT20-N214B Laser Displacement Sensor

BrandSICK
Model IdentifierDT20-N214B
Official Part Number1040140

Technical Overview

The SICK DT20-N214B measures object distance over 100–600 mm at 6–90% remission using a visible red Class 2 laser. Separate outputs provide an NPN switching signal and 12-bit 4–20 mA distance feedback, with maximum analog load of 300 Ω. Fast, medium and slow averaging adapt operation to the process; teach-in and inversion apply to the digital and analog outputs. An LC display, two indicator LEDs and local keys support setup, while the multifunction input provides laser-off or external teaching. The 10–30 V DC device uses an IP65 zinc diecast housing, PMMA front window and turnable M12 five-pin connector, with operation from −20 to +55 °C specified at 24 V.

100–600 mm laser distance sensor at 6–90% remission, with Class 2 red laser, NPN switching, 4–20 mA output and LC display.

Key Features

  • 100–600 mm measuring range at 6–90% remission
  • Visible Class 2 red laser; typical spot 3 × 6 mm at 600 mm
  • Repeatability ≥0.5 mm; depends on averaging/sensitivity and regular application calibration
  • Linearity ±2 mm at 90% remission with regular application calibration
  • Separate NPN digital output, ≤100 mA, and 4–20 mA current output
  • 12-bit analog output; maximum receiver load ≤300 Ω
  • Response ≥2.5 ms, dependent on averaging/sensitivity; measuring frequency ≤400 Hz at 6–90% remission
  • Teach-in and inversion of digital and analog outputs; laser-off/external-teach multifunction input
  • LC display, two status LEDs, local keys, key lock and display deactivation
  • 10–30 V DC; ≤1.8 W without load; IP65 zinc diecast housing and turnable M12 five-pin connector

Combine a taught distance threshold with a separately scaled current signal to support external inspection and process control from one sensor.

Technical Specification Matrix

ParameterValue
Functional principleLaser distance/displacement measurement
Measuring range100–600 mm; 6–90% remission
Repeatability≥0.5 mm; 6–90% remission; depends on averaging or sensitivity; regular calibration in application
Linearity±2 mm; 90% remission, regular calibration in application
Response time≥2.5 ms, dependent on averaging/sensitivity
Measuring frequency≤400 Hz; 6–90% remission
Output time≥2.5 ms
Light sourceVisible red laser
Laser class2; IEC 60825-1:2014, EN 60825-1:2014
Light spot sizeTypically 3 × 6 mm at 600 mm
Digital outputOne NPN output; maximum ≤100 mA
Analog outputOne separate 4–20 mA current output; maximum load ≤300 Ω
Analog output resolution12 bit
Switching modeDistance to Object (DtO); digital output teach-in and inversion
AveragingFast / Medium / Slow
Multifunction inputOne input: laser-off, external teach-in or deactivated
DisplayLC display and two LEDs: power green, digital output orange
AdjustmentLocal keys; display deactivation and user-interface lock
Power supply10–30 V DC; reverse-polarity protected; short-circuit protected network, maximum 8 A
Power consumption≤1.8 W without load
Residual ripple≤5 Vpp; remain within supply voltage limits
Warm-up time≤10 min
ConnectionTurnable male M12 five-pin connector
Pin assignment1 BN=L+; 4 BK=Q NPN; 3 BU=M; 2 WH=QA current output; 5 GY=MF input
MountingØ4.5 mm fixing hole and slot
Housing materialZinc diecast metal
Window materialPMMA plastic
IP ratingIP65 (EN 60529)
Protection classII
Operating temperature−20 to +55 °C at supply 24 V
Storage temperature−20 to +60 °C
Temperature drift0.25 mm/K
Ambient light immunityArtificial light ≤3,000 lx; sunlight ≤10,000 lx
Vibration resistanceEN 60068-2-6, EN 60068-2-64
Shock resistanceEN 60068-2-27
MTTFD101 years
DCavg0%
Physical Weight (kg)0.135

Industrial Applications

1. Checking a seated part face in an assembly fixture

An assembly fixture can position a sufficiently reflecting part face within the 100–600 mm measuring range and teach a switching threshold around its expected distance. External sequence control evaluates the NPN output before the following assembly step. Actual face geometry, mounting orientation, regular application calibration and expected displacement are considered when setting a useful threshold for the fixture.

Problem Solved

A taught distance threshold gives external fixture control an electrical reference for the expected part-face position, helping identify a displaced component before the next assembly operation.

Fixture position NPN threshold Distance to Object

2. Following a feed-material loop with current feedback

A feed station can aim the sensor at a reflecting material loop and keep the surface inside the 100–600 mm measuring range. External feed control receives the separate 4–20 mA signal as the loop moves. The analog endpoints are taught to the useful working span, while averaging and actual surface returns are evaluated against the required control response.

Problem Solved

A scaled current signal supplies external feed control with changing loop-position feedback, helping it recognize movement toward a process limit without placing a mechanical follower on the material.

Loop position 4–20 mA Selectable averaging

3. Evaluating a deposited layer against a carrier reference

A coating or deposition station can present the top surface of a reflecting layer to the sensor at a known carrier reference. External inspection control evaluates the analog distance against the baseline to estimate deposited height. The 100–600 mm range, surface remission, regular application calibration and stated linearity determine whether the expected height differences can be resolved in the installed process.

Problem Solved

A surface-distance comparison against the carrier baseline provides an external deposited-height estimate, helping recognize a changed application result before the carrier moves to the next processing stage.

Layer height Baseline comparison Analog inspection