Domestic TeSys Deca GV2 – GV2PM – Thermal Magnetic Motor Circuit Breakers – Schneider Circuit Breakers

$ 33.60$ 42.72

SKU: N/A

Specifications

Main information
Part Number GV2PM07C GV2PM10C GV2PM16C GV2PM20C
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
product name TeSys GV2 TeSys GV2 TeSys GV2 TeSys GV2
product short name GV2PM GV2PM GV2PM GV2PM
product type Breaker Breaker Breaker Breaker
Applications Motor protection Motor protection Motor protection Motor protection
number of poles 3P 3P 3P 3P
Additional information
Grid type AC AC AC AC
Network frequency 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2
control type Knob Knob Knob Knob
installation method Rail installation Rail installation Rail installation Rail installation
installation location Vertical Vertical Vertical Vertical
horizontal direction horizontal direction horizontal direction horizontal direction
Motor power (kW) 0.37 kW at 230 V AC 50/60 Hz 1.1 kW at 230 V AC 50/60 Hz 3 kW at 230 V AC 50/60 Hz 4 kW at 230 V AC 50/60 Hz
0.75 kW at 400 V 2.2 kW at 400 V 5.5 kW at 400 V 7.5 kW at 400 V
0.75 kW at 415 V 2.2 kW at 415 V 5.5 kW at 415 V 9 kW at 415 V
1.1 kW at 440 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 7.5 kW at 440 V AC 50/60 Hz 9 kW at 440 V AC 50/60 Hz
Rated current [In] 2.5A 6.3A 14A 18A
Trip unit type Thermomagnetic Thermomagnetic Thermomagnetic Thermomagnetic
Electromagnetic trip current 33.5A 78A 170A 223A
Thermal overload protection setting range 1.6…2.5 A 4…6.3A 9…14A 13…18A
isolation function Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6
Mechanical shock resistance 0.5 J IK04 0.5 J IK04 0.5 J IK04 0.5 J IK04
phase loss sensitivity Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2
use category Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2
AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1
Rated working voltage [Ue] 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui] 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2
600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508
600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14
Conventional thermal current [Ith] 2.5 A conforming to IEC 60947-4-1 6.3 A conforming to IEC 60947-4-1 13 A conforming to IEC 60947-4-1 17 A conforming to IEC 60947-4-1
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 947-2 6 kV according to IEC 947-2 6 kV according to IEC 947-2 6 kV according to IEC 947-2
power consumption per pole 2.5W 2.5W 2.5W 2.5W
Mechanical life 100000 times 100000 times 100000 times 100000 times
Electrical life 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In
100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2
maximum conversions 25 cyc/h 25 cyc/h 25 cyc/h 25 cyc/h
specified load Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1
Wiring capacity Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit:
Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals
Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals
Tightening torque 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm²
1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm²
1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm²
Breaking capacity Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 8 kA at… at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 8 kA at… at 440 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 6 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 6 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 3 kA at 690 V AC 50/ 60 Hz conforming to IEC 60947-2 Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947- 2 Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947- 2
Rated operating short-circuit breaking capacity [Ics] 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
high 89 mm 89 mm 89 mm 89mm
width 44.5 mm 44.5 mm 44.5 mm 44.5 mm
depth 91 mm 91 mm 91 mm 91 mm
product weight 0.26kg 0.26kg 0.26kg 0.26kg
Environment
Standards compliant GB 14048.4 GB 14048.4 GB 14048.4 GB 14048.4
IEC 60947-1 IEC 60947-1 IEC 60947-1 IEC 60947-1
IEC 60947-2 IEC 60947-2 IEC 60947-2 IEC 60947-2
IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1
certified product CCC CCC CCC CCC
UKCA UKCA UKCA UKCA
CE CE CE CE
Protective measures TH TH TH TH
IP protection class IP20 complies with screwed (body) IP20 complies with screwed (body) IP20 complies with screwed (body) IP20 complies with screwed (body)
Shock and vibration resistance Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27
Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6
ambient temperature -20…40 °C In cabinet -20…40 °C In cabinet -20…40 °C In cabinet -20…40 °C In cabinet
-20…60 °C Body -20…60 °C Body -20…60 °C Body -20…60 °C Body
storage environment temperature -40…80°C -40…80°C -40…80°C -40…80°C
Fire resistance and abnormal high temperature resistance 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1
working altitude <= 2000m <= 2000m <= 2000m <= 2000m
Packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 5.6cm 5.218 cm 4.79cm 5.6cm
Package 1 Width 9.4 cm 9.3 cm 9.09 cm 9.8 cm
Package 1 Length 9.9 cm 9.685 cm 9.61 cm 10.2 cm
Package 1 Weight 284.3g 298.0g 305.25g 312.0g
Unit Type of Package 2 S02 S02 S02 S02
Number of Units in Package 2 20 20 20 20
Package 2 Height 15.0cm 15.0cm 15.0cm 15.0cm
Package 2 Width 30.0cm 30.0cm 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm 40.0cm 40.0cm
Package 2 Weight 6.078 kg 6.369 kg 6.497 kg 6.636 kg
Unit Type of Package 3 P06 P06 P06 P06
Number of Units in Package 3 400 400 400 400
Package 3 Height 90.0cm 90.0cm 90.0cm 90.0cm
Package 3 Width 60.0cm 60.0cm 60.0cm 60.0cm
Package 3 Length 80.0cm 80.0cm 80.0cm 80.0cm
Package 3 Weight 131.56kg 137.38kg 139.94kg 142.72kg
Contract warranty
Warranty 18 months 18 months 18 months 18 months

 

 

Main information
Part Number GV2PM21C GV2PM22C GV2PM32C
Product Series TeSys Deca TeSys Deca TeSys Deca
product name TeSys GV2 TeSys GV2 TeSys GV2
product short name GV2PM GV2PM GV2PM
product type Breaker Breaker Breaker
Applications Motor protection Motor protection Motor protection
number of poles 3P 3P 3P
Additional information
Grid type AC AC AC
Network frequency 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2
control type Knob Knob Knob
installation type Fixed
installation method Rail installation Rail installation Rail installation
installation location Vertical horizontal Vertical
horizontal direction Vertical horizontal direction
Motor power (kW) 5.5 kW at 230 V AC 50/60 Hz 5.5 kW at 230 V AC 50/60 Hz 7.5 kW at 230 V AC 50/60 Hz
11 kW at 400 V 11 kW at 400 V 15 kW at 400 V
11 kW at 415 V 11 kW at 415 V 15 kW at 415 V
11 kW at 440 V AC 50/60 Hz 11 kW at 440 V AC 50/60 Hz 15 kW at 440 V AC 50/60 Hz
Rated current [In] 23A 25A 32A
Trip unit type Thermomagnetic Thermomagnetic Thermomagnetic
Electromagnetic trip current 327A 327A 416A
Thermal overload protection setting range 17…23A 20…25A 24…32A
isolation function Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6
Mechanical shock resistance 0.5 J IK04 0.5 J IK04 0.5 J IK04
phase loss sensitivity Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2
use category Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2
AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1
Rated working voltage [Ue] 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui] 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2
600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508
600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14
Conventional thermal current [Ith] 21 A conforming to IEC 60947-4-1 23 A conforming to IEC 60947-4-1 24 A conforming to IEC 60947-4-1
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 947-2 6 kV according to IEC 947-2 6 kV according to IEC 947-2
power consumption per pole 2.5W 2.5W 2.5W
Mechanical life 100000 times 100000 times 100000 times
Electrical life 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In
100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2
maximum conversions 25 cyc/h 25 cyc/h 25 cyc/h
specified load Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1
Wiring capacity Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit:
Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals
Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals
Tightening torque 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm²
1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm²
1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm²
Breaking capacity Icu: 50 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 50 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 50 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 10 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 6 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 6 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 6 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 4 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 4 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 4 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operating short-circuit breaking capacity [Ics] 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
40 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 40 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
high 89mm 89 mm 89 mm
width 44.5 mm 44.5 mm 44.5 mm
depth 91 mm 91 mm 91 mm
product weight 0.26kg 0.26kg 0.26kg
Environment
Standards compliant GB 14048.4 GB 14048.4 GB 14048.4
IEC 60947-1 IEC 60947-1 IEC 60947-1
IEC 60947-2 IEC 60947-2 IEC 60947-2
IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1
certified product CCC CCC CCC
UKCA UKCA UKCA
CE CE CE
Protective measures TH TH TH
IP protection class IP20 complies with screwed (body) IP20 complies with screwed (body) IP20 complies with screwed (body)
Shock and vibration resistance Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27
Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6
ambient temperature -20…40 °C In cabinet -20…40 °C In cabinet -20…40 °C In cabinet
-20…60 °C Body -20…60 °C Body -20…60 °C Body
storage environment temperature -40…80°C -40…80°C -40…80°C
Fire resistance and abnormal high temperature resistance 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1
working altitude <= 2000m <= 2000m <= 2000m
Packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 5.152 cm 9.03 cm 9.05cm
Package 1 Width 9.038 cm 9.35cm 9.34 cm
Package 1 Length 9.331 cm 4.88cm 4.78cm
Package 1 Weight 314.5g 308.65g 305.85 g
Unit Type of Package 2 S02 S02 S02
Number of Units in Package 2 20 20 20
Package 2 Height 15.0cm 15.0cm 15.0cm
Package 2 Width 30.0cm 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm 40.0cm
Package 2 Weight 6.63kg 6.565kg 6.509kg
Unit Type of Package 3 P06 P06 P06
Number of Units in Package 3 400 400 400
Package 3 Height 90.0cm 90.0cm 90.0cm
Package 3 Width 60.0cm 60.0cm 60.0cm
Package 3 Length 80.0cm 80.0cm 80.0cm
Package 3 Weight 142.6 kg 141.3kg 140.18kg
Contract warranty
Warranty 18 months 18 months 18 months
Weight N/A
Dimensions N/A
Amp a

14, 18, 2.5, 23, 25, 32, 6.3