Please enable JavaScript to view this site.

IDS Software Suite 4.97

Digital input specifications

 

Min.

Max.

 

Level low

0

1

V

Level high

5

24

V

Trigger pulse width (edge)

10

-

µs

Trigger edge steepness

35

-

V/ms

Breakdown voltage

-

50

V

Input current

-

10

mA

For interpreting the trigger signal, either the rising or the falling edge can be used. The digital input is galvanically isolated using an optocoupler to protect the camera and the PC against surges. Only DC voltages may be applied to the digital input.

The signal source of the trigger must be able to carry a load of at least 20 mA.

Digital input wiring

Fig. 378: USB 3 uEye CP Rev. 2 - Wiring of the trigger connector

Fig. 378: USB 3 uEye CP Rev. 2 - Wiring of the trigger connector

Absolute maximum rating

 

Symbol

Max.

Unit

Voltage range

VCC

30

V