Please enable JavaScript to view this site.

IDS peak 2.15.0 / uEye+ firmware 3.54

Returns the maximum number of data blocks that can be stored in the block queue.

Name

TransferQueueMaxBlockCount

Category

TransferControl

Interface

Integer

Access

Read

Unit

-

Visibility

Expert

Values

> 0

Standard

SFNC

Availability uEye+

icon-gev icon-u3v

Availability uEye

-

Code example

C++

// Determine the current TransferQueueMaxBlockCount
int64_t value = nodeMapRemoteDevice->FindNode<peak::core::nodes::IntegerNode>("TransferQueueMaxBlockCount")->Value();

C#

// Determine the current TransferQueueMaxBlockCount
long value = nodeMapRemoteDevice.FindNode<peak.core.nodes.IntegerNode>("TransferQueueMaxBlockCount").Value();

Python

# Determine the current TransferQueueMaxBlockCount (int)
value = nodeMapRemoteDevice.FindNode("TransferQueueMaxBlockCount").Value()