The SignalMultiplierValue defines the number of internal signals that are generated within the period of the reference signal. The Reference Signal is defined in SignalMultiplierSource.

Name

SignalMultiplierValue[SignalMultiplierSelector]

Category

SignalMultiplierControl

Interface

Integer

Access

Read/Write

Unit

-

Visibility

Expert

Values

1 ... 128

Standard

IDS

Availability uEye+

icon-gev

Availability uEye

-

Code example

C++

// Determine the current SignalMultiplierValue
int64_t value = nodeMapRemoteDevice->FindNode<peak::core::nodes::IntegerNode>("SignalMultiplierValue")->Value();
// Set SignalMultiplierValue to 1
nodeMapRemoteDevice->FindNode<peak::core::nodes::IntegerNode>("SignalMultiplierValue")->SetValue(1);

C#

// Determine the current SignalMultiplierValue
long value = nodeMapRemoteDevice.FindNode<peak.core.nodes.IntegerNode>("SignalMultiplierValue").Value();
// Set SignalMultiplierValue to 1
nodeMapRemoteDevice.FindNode<peak.core.nodes.IntegerNode>("SignalMultiplierValue").SetValue(1);

Python

# Determine the current SignalMultiplierValue (int)
value = nodeMapRemoteDevice.FindNode("SignalMultiplierValue").Value()
# Set SignalMultiplierValue to 1 (int)
nodeMapRemoteDevice.FindNode("SignalMultiplierValue").SetValue(1)