Siemens SIPART PS2 Analog Output Module 4-20mA Feedback

USD 542.29

Analog Output Module for SIPART PS2. Provides 4-20mA position feedback for valve control with high accuracy.

SKU Siemens-6DR4004-8J Category
Top Brands > Siemens > Siemens Positioner

Siemens SIPART PS2 Analog Output Module 4-20mA Feedback

Model Identifier Analog Output Module (AOM)
Official Part Number 6DR4004-8J
GTIN Standard 4019169840743

Technical Overview

Analog Output Module for SIPART PS2. Provides 4-20mA position feedback for valve control with high accuracy.

Key Features

  • Plug-in accessory for SIPART PS2 electropneumatic positioner.
  • Provides analog current output signal for position feedback (4-20 mA).
  • 2-wire connection.
  • Short-circuit-proof.
  • Operating voltage: +12 to +35 V DC.
  • Non-explosion-proof version.
  • High accuracy with transmission error ≤0.3%.
  • Electrical isolation from the basic unit/control circuit.
  • Wide operating temperature range of -30°C to +80°C (inherent to SIPART PS2 housing).
  • IP66 rated (inherent to SIPART PS2 housing).

Analog position feedback via 4-20 mA current output for remote valve monitoring.

Technical Specification Matrix

ParameterValue
Signal Output4-20 mA analog current
Nominal Signal Range4-20 mA
Maximum Operating Range3.6-20.5 mA
Power Supply (non-Ex)+12 to +35 V DC
Connection Type2-wire
Short-circuit ProtectionYes
Transmission Error≤0.3%
Temperature Influence≤0.1% per 10 K
Resolution≤0.1%
Residual Ripple≤1%
Internal Capacitance11 nF
Explosion ProtectionNo (non-Ex version)
Electrical IsolationFull isolation from control circuit
Operating Temperature Range-30°C to +80°C
IP RatingIP66
Physical Weight (kg)0.05
Dimensions L x W x H (cm)12.1 x 7.5 x 3.4

Industrial Applications

1. Process Control Valve Monitoring in Chemical Plants

In chemical processing, precise control of fluid flow through valves is critical. This module, when integrated with a SIPART PS2 positioner, provides highly accurate (≤0.3% error) and continuous 4-20 mA analog feedback of valve stem or rotary position. This allows the Distributed Control System (DCS) to precisely monitor and log the actual valve opening, ensuring process stability and safety. The wide operating temperature range (-30°C to +80°C) and IP66 rating ensure reliability in harsh plant environments.

Problem Solved

Ensures accurate, real-time feedback of valve position in critical chemical processes, enabling precise control, fault detection (via fault current 3.6 mA), and compliance with operational parameters, even in demanding industrial conditions.

4-20 mAposition feedbackprocess controlvalve actuationDCS integrationIP66-30°C to +80°Chigh accuracychemical processing

2. Remote Valve Status Indication in Water Treatment Facilities

Water and wastewater treatment plants often have numerous valves spread across large areas. The 6DR4004-8J, with its 2-wire, 4-20 mA output and electrical isolation, is ideal for providing remote and reliable valve position feedback to a central SCADA system. Its non-explosion-proof nature is suitable for non-hazardous areas typical of many water treatment processes, and the robust IP66 protection protects against water jets and dust.

Problem Solved

Enables cost-effective, real-time remote monitoring of valve positions across a geographically dispersed water treatment plant, improving operational efficiency, rapid fault identification, and preventing costly spills or disruptions.

SCADAremote monitoring4-20 mA outputwater treatmentvalve position2-wireelectrical isolationIP66

3. HVAC System Damper Position Feedback in Large Industrial Buildings

In large industrial HVAC systems, pneumatic actuators often control air dampers. The 6DR4004-8J module, coupled with a SIPART PS2 positioner, can provide precise analog feedback of damper position (4-20 mA) to a Building Management System (BMS). This allows for optimized airflow control, energy efficiency, and detailed diagnostics of the HVAC system's performance. The +12 to +35 V DC power supply is common in control systems.

Problem Solved

Provides accurate and continuous feedback of HVAC damper positions, allowing a BMS to achieve optimal climate control, improve energy efficiency, and proactively identify malfunctioning dampers for maintenance.

HVACdamper controlBuilding Management System (BMS)4-20 mAanalog feedbackenergy efficiencypneumatic actuation+12 to +35 V DC