1. Electrical Separation in High-Density Control Cabinets
This partition plate is ideal for control cabinets with mixed signal types (e.g., sensitive control signals and power circuits) mounted on DIN rails. Its compact 1.5mm width and electrical isolation capabilities are crucial for maintaining high wiring density without compromising safety or signal integrity.
Problem SolvedPrevents electrical interference (EMI/RFI) and ensures safe voltage separation between different terminal groups, complying with industrial safety standards in space-constrained enclosures.
EMI/RFI shieldingvoltage separationmixed signal wiringcontrol cabinetDIN railcompact designelectrical isolation
2. Safety-Critical Systems in Extreme Temperature Environments
For safety-related circuits in machinery or process control systems exposed to wide temperature variations, the ATP-UK partition plate maintains its insulation properties. Its robust operating temperature range of -60 °C to 110 °C and UL 94 V0 flammability rating ensure reliable performance.
Problem SolvedGuarantees consistent electrical separation and fire safety even under extreme thermal stress, mitigating the risk of electrical faults and ensuring operational reliability in demanding environments like outdoor enclosures or unheated industrial facilities.
Safety integrityharsh environmenttemperature resistance (-60°C to 110°C)UL 94 V0fire protectionelectrical fault prevention
3. Electrical Isolation in Rail Vehicle Control Systems
Due to its compliance with stringent fire protection standards for rail vehicles (DIN EN 45545-2 R22, R23, R24, R26; HL 1 - HL 3), this partition plate is perfectly suited for segmenting electrical circuits within rail vehicle applications.
Problem SolvedProvides robust electrical isolation and meets critical fire safety requirements (low smoke, low toxicity, low heat release) mandated by the rail industry, ensuring system reliability and passenger safety in a dynamic and temperature-varying environment.
Rail industryDIN EN 45545-2fire protectionelectrical isolationvibration resistancecontrol systemslow smokelow toxicity