$ 165.37
Compact Phoenix Contact MINI MCR-2-RPSS-I-I-PT repeater power supply with 3-way isolation, HART transparency, and reliable transmitter support.
The Phoenix Contact MINI MCR-2-RPSS-I-I-PT repeater power supply is a compact and reliable solution for isolating and powering transmitters in process automation. Built in a slim 6.2 mm housing, it provides three-way galvanic isolation between input, output, and power supply, ensuring dependable performance even in noise-prone environments. Designed for handling 0(4)…20 mA signals with full HART transparency, it supports seamless integration into advanced control systems. With quick push-in wiring and high efficiency, this device addresses the challenge of maintaining safe, interference-free current loops while saving valuable space inside control cabinets.
The MINI MCR-2-RPSS-I-I-PT combines signal isolation, transmitter supply, and monitoring functions in one device. It enables bidirectional transfer of HART data, provides fault monitoring, and supports NFC configuration for simplified setup and diagnostics. Its fast response time and low transmission error guarantee precise measurements, while the ability to drive loads up to 600 ohms makes it versatile across industries. With certifications for use in hazardous areas and a wide operating temperature range, it ensures consistent performance in demanding conditions. By improving measurement reliability and minimizing downtime, this unit helps engineers increase efficiency and extend system life in industrial plants.
The Phoenix Contact MINI MCR-2-RPSS-I-I-PT stands out for its precision, compact design, and adaptability. It combines transmitter power supply, galvanic isolation, and HART transparency in one slim 6.2 mm module. Engineers choose it because it simplifies wiring, saves cabinet space, and delivers reliable signal integrity in even the harshest automation environments.
Industrial plants struggle with signal interference, inaccurate measurements, and limited cabinet space. The MINI MCR-2-RPSS-I-I-PT solves these issues by providing three-way isolation, reducing noise, and ensuring error-free current loop transmission. With built-in diagnostics and support for modern communication standards, it keeps processes stable, prevents costly downtime, and helps maintain long-term system efficiency.
Feature | Details | Benefit |
---|---|---|
Housing Width | 6.2 mm | Saves valuable DIN rail space in control cabinets |
Isolation | 3-way galvanic isolation | Protects devices from interference and improves safety |
Input/Output Signal | 0(4)–20 mA | Standardized signal compatibility for process automation |
HART Transparency | Yes, bidirectional | Ensures seamless integration with HART-enabled devices |
Response Time | <200 µs | Fast reaction for real-time control and monitoring |
Transmission Accuracy | ≤0.05% | High precision for reliable measurement results |
Load Capacity | Up to 600 Ω | Supports long cable runs and higher resistance loads |
Supply Voltage | 9.6…30 V DC | Flexible power range for global installations |
Connection Technology | Push-in terminals | Quick and secure wiring, reduces installation time |
Ambient Temperature | -40 °C to +70 °C | Reliable performance in extreme industrial environments |
Approvals | ATEX, IECEx, UL, CE | Certified for use in hazardous and global applications |
Download MINI MCR-2-RPSS-I-I-PT 2902015 Datasheet
Commercial Data | Details |
---|---|
GTIN Number | 4046356649544 |
Customs Tariff Number | 85437090 |
Weight | 88 g (excl. packaging) / 118 g (incl. packaging) |
Country of Origin | Germany |
Water treatment facilities rely on precise measurements of pH, turbidity, and chemical dosing levels. Sensors in these environments often sit far from control panels, and long cable runs are prone to electrical noise. The MINI MCR-2-RPSS-I-I-PT provides three-way isolation, shielding signals from interference and eliminating ground loop problems. With its ability to transmit HART data, operators can remotely calibrate instruments and review diagnostics. Its high load capability ensures stable transmission over extended distances, guaranteeing that control systems receive accurate and uninterrupted feedback. This helps maintain compliance with quality standards and ensures safe, clean water delivery to communities.
Offshore oil and gas platforms operate in hazardous areas where reliable instrumentation is vital for safety. Pressure and level transmitters must be isolated to prevent electrical faults from spreading across the system. The MINI MCR-2-RPSS-I-I-PT, with its certifications for hazardous environments, ensures safe operation while maintaining precise measurement loops. Its compact design fits easily into crowded control panels, while the device’s support for HART communication enables technicians to check sensor health remotely, minimizing exposure to hazardous zones. By ensuring accurate signal transfer and protection against interference, it supports safer and more efficient platform operations.
Power plants depend on continuous monitoring of oxygen and gas levels to manage combustion processes. These signals can easily be distorted by electrical noise from motors and high-voltage equipment. The MINI MCR-2-RPSS-I-I-PT addresses this with fast response time and minimal transmission error, allowing critical feedback to be delivered with precision. Its isolation properties protect sensitive measurement equipment from surges and disturbances. Quick push-in wiring and a slim 6.2 mm profile make it simple to integrate into existing panels. By ensuring stable and accurate signal handling, it supports more efficient fuel usage, reduced emissions, and safer boiler operation.
Remote pumping stations often operate in damp, vibration-prone conditions where power supplies can be unstable. Level probes and flow sensors need stable current loops to send accurate data to supervisory systems. The MINI MCR-2-RPSS-I-I-PT, with its wide input voltage range and rugged reliability, ensures dependable operation even under fluctuating supply conditions. Its ability to maintain signal accuracy over long distances reduces the risk of false alarms and unnecessary maintenance visits. With HART transparency, technicians can diagnose and adjust sensors without on-site intervention, saving time and costs. This ensures smoother wastewater management and improved long-term infrastructure performance.
Category | Product | Article Number | Function / Benefit |
---|---|---|---|
DIN Rail Bus Connectors | ME 6,2 TBUS-2 1,5/5-ST-3,81 GY | 2695439 | 5-position bus connector for bridging supply voltage across modules |
ME 6,2 TBUS-2 1,5/5-ST-3,81 GN | 2869728 | Universal TBUS connector with gold-plated contacts for MINI Analog Pro | |
Communication Modules | GW HART USB MODEM | 1003824 | USB modem cable for communication between PC and HART devices |
MINI MCR-2-V8-MOD-RTU | 2905634 | Connects up to 8 MINI Analog Pro devices to Modbus/RTU networks | |
MINI MCR-2-V8-MOD-TCP | 2905635 | Adapter for Modbus/TCP communication with multiple signal conditioners | |
MINI MCR-2-V8-PB-DP | 2905636 | PROFIBUS DP module for integrating multiple devices | |
MINI MCR-2-V8-PN | 2905637 | PROFINET adapter for network connectivity of MINI Analog Pro modules | |
Module Carriers & Adapters | TC-D37SUB-AIO16-MP-PS-UNI | 2906640 | Termination carrier for 16 signal conditioners with HART multiplexer |
TC-D37SUB-ADIO16-MP-P-UNI | 2906639 | Universal termination carrier with D-SUB connector | |
MINI MCR-2-V8-FLK 16 | 2901993 | System adapter for connecting up to 8 signal conditioners with minimal cabling | |
Power & Monitoring | MINI MCR-2-PTB | 2902066 | Power terminal block with screw connection for supply monitoring |
MINI MCR-2-PTB-PT | 2902067 | Power terminal block with push-in connection | |
MINI MCR-2-FM-RC | 2904504 | Fault monitoring module with screw connection | |
MINI MCR-2-FM-RC-PT | 2904508 | Fault monitoring module with push-in connection | |
QUINT4-SYS-PS/1AC/24DC/2.5/SC | 2904614 | Primary switched-mode power supply, 24 V DC / 2.5 A | |
Connector Sets | FASTCON PRO-SET | 2906227 | Connector set with screw connection for MINI Analog Pro modules |
FASTCON PRO-SET-PT | 2906228 | Connector set with push-in connection | |
Marking Accessories | UCT-EM, UC-EMLP, US-EMLP Markers | Various | Labeling accessories for clear identification of terminals and modules |
Tools | SZS 0,6X3,5 Screwdriver | 1205053 | Insulated screwdriver for terminal actuation and secure wiring |
For expert guidance before placing your order.
Warranty – 1-year warranty for your peace of mind.
Global Shipping – We ship worldwide with secure packaging and reliable delivery.
Technical Support – Contact us for professional after-sales technical assistance.