G6B-4[][]ND – Omron Terminal Relays
USD 37.03 – USD 91.78Price range: USD 37.03 through USD 91.78
List of Models
When your order, specify the rated voltage.
| Classification |
Contact form |
Mounting method |
Terminals |
Model |
Rated voltage |
Equipped with
operation
indicator and
diode to absorb
coil surge |
4PST (standard) |
DIN Track or screw
mounting |
Phillips screw
terminal |
G6B-4BND |
5 VDC
12 VDC
24 VDC |
| 4PST (long-life) |
DIN Track or screw
mounting |
Phillips screw
terminal |
G6B-47BND |
5 VDC
12 VDC
24 VDC |
| 4PST (high reliability) |
DIN Track or screw
mounting |
Phillips screw
terminal |
G6B-48BND |
5 VDC
12 VDC
24 VDC |
| 4PST (standard) |
Screw mounting |
Flat-bladed screw
terminal |
G6B-4FB1ND |
5 VDC
12 VDC
24 VDC |
| 4PST (standard) |
Screw mounting |
Connector |
G6B-4FPND |
5 VDC
12 VDC
24 VDC |
Note: 1. For replacement relays, use relays with the same voltage specifications as the relays provided with the Terminal
when it was purchased.
Longer operating life can be achieved by replacing the G6B-4[][]ND with the G6B-1174P-FD-US-P6B.
2. Standard models and long-life models are also available without relays mounted to the sockets
3. SSR-equipped G3S4 models are also available. Refer to information on the G3S4 (Data Sheet).
Ratings
Coil Ratings (per G6B Relay)
| Rated voltage |
5 VDC |
12 VDC |
24 VDC |
| Rated current |
35.5 mA (43.4) |
19.1 mA |
10.7 mA (10.3) |
| Coil resistance |
125 Ω |
720 Ω |
2,880 Ω |
| Must operate voltage |
80% max. of rated voltage |
| Must release voltage |
10% min. of rated voltage |
| Max. voltage |
130% of rated voltage |
| Power consumption |
Approx. 200 mW |
Note: 1. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics were measured at a coil temperature of 23°C.
3. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating
power supply. There is no continuous allowance.
4. Diodes to absorb coil surge are equivalent to S5688J (reverse voltage resistance: 600 V; forward current: 1 A).
5. The values in parentheses are for the G6B-4FB1ND and G6B-4FPND.
6. The rated current includes the LED current.
Contact Ratings
| Classification |
G6B-4BND (standard), G6B-47BND (long-life) |
G6B-48BND (high-reliability) |
| Load |
Resistive load
(cosφ = 1) |
Inductive load
(cosφ = 0.4, L/R = 7 ms) |
Resistive load
(cosφ = 1) |
Inductive load
(cosφ = 0.4, L/R = 7 ms) |
| Rated load |
5 A at 250 VAC,
5 A at 30 VDC |
2 A at 250 VAC,
2 A at 30 VDC |
2 A at 250 VAC,
2 A at 30 VDC |
0.5 A at 250 VAC,
0.5 A at 30 VDC |
| Rated carry current |
5 A |
2 A |
| Max. switching voltage |
380 VAC, 125 VDC |
| Max. switching current |
5 A |
2 A |
2 A |
0.5 A |
| Max. switching power |
1,250 VA, 150 W |
500 VA, 60 W |
500 VA, 60 W |
125 VA, 15 W |
Error rate (reference
value) (see note) |
10 mA at 5 VDC |
1 mA at 1 VDC |
Note: This value fulfills the P reference value of opening/closing at a rate of 120 times per min (ambient operating
environment and determination criteria according to JIS C5442).
Characteristics
Contact resistance
(see note 2) |
100 mΩ max. |
| Operate time |
10 ms max. (approx. 3 ms) |
| Release time |
15 ms max. (approx. 4 ms) |
| Insulation resistance |
1,000 MΩ min. (at 500 VDC) |
| Dielectric strength |
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
250 VAC, 50/60 Hz for 1 min between coils of different polarity |
| Vibration resistance |
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
| Shock resistance |
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G) |
| Endurance |
Mechanical: 50,000,000 operations min. (at 18,000 operations/hr)
Electrical:
100,000 operations min. (at 1,800 operations/hr, rated load)
500,000 operations min. for long-life at 2 A
100,000 operations min for long-life at 5 A |
| Ambient temperature |
Operating: -25°C to 55°C (with no icing or condensation)
Storage: -25°C to 55°C (with no icing or condensation) |
| Ambient humidity |
Operating: 35% to 85% |
| Weight |
Approx. 75 g |
Note: 1. The above values are initial values.
2. Measurement condition: 1 A at 5 VDC