SIRIUS – 3RV6021 – 3 Poles Circuit Breaker – Siemens Circuit Breakers

$ 32.34$ 80.96

SKU: N/A

Specifications

Part number 3RV6021-4AA10 3RV6021-4BA10 3RV6021-4CA10 3RV6021-4DA10
product brand name  SIRIUS  SIRIUS  SIRIUS  SIRIUS
product designation Circuit breaker Circuit breaker Circuit breaker Circuit breaker
design of the product for motor protection for motor protection for motor protection for motor protection
product type designation 3RV6 3RV6 3RV6 3RV6
General technical data
size of the circuit-breaker S0 S0 S0 S0
power loss [W] total typical 7 W 8 W 8 W 8 W
insulation voltage with degree of pollution 3 at AC rated value 690 V 690 V 690 V 690 V
surge voltage resistance rated value 6 kV 6 kV 6 kV 6 kV
shock resistance according to IEC 60068-2-27 25g / 11 ms 25g / 11 ms 25g / 11 ms 25g / 11 ms
Substance Prohibitance (Date) 5/1/2012 5/1/2012 5/1/2012 5/1/2012
Ambient conditions
installation altitude at height above sea level maximum 2 000 m 2 000 m 2 000 m 2 000 m
ambient temperature
? during operation -20 … +60 °C -20 … +60 °C -20 … +60 °C -20 … +60 °C
? during transport -50 … +80 °C -50 … +80 °C -50 … +80 °C -50 … +80 °C
relative humidity during operation 10 … 95 % 10 … 95 % 10 … 95 % 10 … 95 %
Main circuit
number of poles for main current circuit 3 3 3 3
adjustable current response value current of the current-dependent overload release 10 … 16 A 13 … 20 A 16 … 22 A 18 … 25 A
operating voltage
rated value 690 V 690 V 690 V 690 V
at AC-3 rated value maximum 690 V 690 V 690 V 690 V
operating frequency rated value 50 … 60 Hz 50 … 60 Hz 50 … 60 Hz 50 … 60 Hz
operational current rated value 25 A 16 A 20 A 22 A 25 A
operational current at AC-3 at 400 V rated value 16 A 20 A 22 A 25 A
operating frequency at AC-3 maximum 15 1/h 15 1/h 15 1/h 15 1/h
Protective and monitoring functions
trip class CLASS 10 CLASS 10 CLASS 10 CLASS 10
design of the overload release thermal thermal thermal thermal
maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value 55 kA 55 kA 55 kA 55 kA
operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value 25 kA 25 kA 25 kA 25 kA
response value current of instantaneous short-circuit trip unit 208 A 260 A 286 A 325 A
Short-circuit protection
product function short circuit protection Yes Yes Yes Yes
design of the short-circuit trip magnetic magnetic magnetic magnetic
Installation/ mounting/ dimensions
mounting position any any any any
fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715
height 97 mm 97 mm 97 mm 97 mm
width 45 mm 45 mm 45 mm 45 mm
depth 96 mm 96 mm 96 mm 96 mm
required spacing for grounded parts
forwards 0 mm 0 mm 0 mm 0 mm
backwards 0 mm 0 mm 0 mm 0 mm
upwards 50 mm 50 mm 50 mm 50 mm
at the side 30 mm 30 mm 30 mm 30 mm
downwards 50 mm 50 mm 50 mm 50 mm
Connections/ Terminals
type of electrical connection
for main current circuit screw-type terminals screw-type terminals screw-type terminals screw-type terminals
arrangement of electrical connectors for main current circuit Top and bottom Top and bottom Top and bottom Top and bottom
type of connectable conductor cross-sections
for main contacts
— solid or stranded 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²)
— finely stranded with core end processing 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm²
at AWG cables for main contacts 2x (16 … 12), 2x (14 … 8) 2x (16 … 12), 2x (14 … 8) 2x (16 … 12), 2x (14 … 8) 2x (16 … 12), 2x (14 … 8)
tightening torque
for main contacts with screw-type terminals 2 … 2.5 N·m 2 … 2.5 N·m 2 … 2.5 N·m 2 … 2.5 N·m
Safety related data
protection class IP on the front according to IEC 60529 IP20 IP20 IP20 IP20
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front finger-safe, for vertical contact from the front finger-safe, for vertical contact from the front finger-safe, for vertical contact from the front
Part number 3RV6021-4EA10 3RV6021-4FA10 3RV6021-4NA10 3RV6021-4PA10
product brand name  SIRIUS  SIRIUS  SIRIUS  SIRIUS
product designation Circuit breaker Circuit breaker Circuit breaker Circuit breaker
design of the product for motor protection for motor protection for motor protection for motor protection
product type designation 3RV6 3RV6 3RV6 3RV6
General technical data
size of the circuit-breaker S0 S0 S0 S0
power loss [W] total typical 11 W 14 W 11 W 14 W
insulation voltage with degree of pollution 3 at AC rated value 690 V 690 V 690 V 690 V
surge voltage resistance rated value 6 kV 6 kV 6 kV 6 kV
shock resistance according to IEC 60068-2-27 25g / 11 ms 25g / 11 ms 25g / 11 ms 25g / 11 ms
Substance Prohibitance (Date) 5/1/2012 5/1/2012 5/1/2012 5/1/2012
Ambient conditions
installation altitude at height above sea level maximum 2 000 m 2 000 m 2 000 m 2 000 m
ambient temperature
? during operation -20 … +60 °C -20 … +40 °C -20 … +60 °C -20 … +40 °C
? during transport -50 … +80 °C -50 … +80 °C -50 … +80 °C -50 … +80 °C
relative humidity during operation 10 … 95 % 10 … 95 % 10 … 95 % 10 … 95 %
Main circuit
number of poles for main current circuit 3 3 3 3
adjustable current response value current of the current-dependent overload release 27 … 32 A 34 … 40 A 23 … 28 A 30 … 36 A
operating voltage
rated value 690 V 690 V 690 V 690 V
at AC-3 rated value maximum 690 V 690 V 690 V 690 V
operating frequency rated value 50 … 60 Hz 50 … 60 Hz 50 … 60 Hz 50 … 60 Hz
operational current rated value 25 A 32 A 40 A 28 A 36 A
operational current at AC-3 at 400 V rated value 32 A 40 A 28 A 36 A
operating frequency at AC-3 maximum 15 1/h 15 1/h 15 1/h 15 1/h
Protective and monitoring functions
trip class CLASS 10 CLASS 10 CLASS 10 CLASS 10
design of the overload release thermal thermal thermal thermal
maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value 55 kA 20 kA 55 kA 20 kA
operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value 25 kA 10 kA 25 kA 10 kA
response value current of instantaneous short-circuit trip unit 400 A 480 A 364 A 432 A
Short-circuit protection
product function short circuit protection Yes Yes Yes Yes
design of the short-circuit trip magnetic magnetic magnetic magnetic
Installation/ mounting/ dimensions
mounting position any any any any
fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715 screw and snap-on mounting onto 35 mm DIN rail according to DIN EN60715
height 97 mm 97 mm 97 mm 97 mm
width 45 mm 45 mm 45 mm 45 mm
depth 96 mm 96 mm 96 mm 96 mm
required spacing for grounded parts
forwards 0 mm 0 mm 0 mm 0 mm
backwards 0 mm 0 mm 0 mm 0 mm
upwards 50 mm 70 mm 50 mm 70 mm
at the side 30 mm 30 mm 30 mm 30 mm
downwards 50 mm 70 mm 50 mm 70 mm
Connections/ Terminals
type of electrical connection
for main current circuit screw-type terminals screw-type terminals screw-type terminals screw-type terminals
arrangement of electrical connectors for main current circuit Top and bottom Top and bottom Top and bottom Top and bottom
type of connectable conductor cross-sections
for main contacts
— solid or stranded 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²)
— finely stranded with core end processing 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm²
at AWG cables for main contacts 2x (16 … 12), 2x (14 … 8) 2x (16 … 12), 2x (14 … 8) 2x (16 … 12), 2x (14 … 8) 2x (16 … 12), 2x (14 … 8)
tightening torque
for main contacts with screw-type terminals 2 … 2.5 N·m 2 … 2.5 N·m 2 … 2.5 N·m 2 … 2.5 N·m
Safety related data
protection class IP on the front according to IEC 60529 IP20 IP20 IP20 IP20
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front finger-safe, for vertical contact from the front finger-safe, for vertical contact from the front finger-safe, for vertical contact from the front
Weight N/A
Dimensions N/A