SICK 6068448 UM30-21211B IO-Link Ultrasonic Sensor

SICK 6068448 UM30-21211B IO-Link Ultrasonic Sensor

USD 428.74

UM30-21211B offers 65–350 mm ultrasonic operation, IO-Link V1.1, one push-pull PNP/NPN output, 64 ms response and an IP65/IP67 M30 housing.

SKU: SICK-6068448 Category:
Ultrasonic Distance Sensors - SICK UM30

SICK UM30-21211B IO-Link Ultrasonic Sensor

BrandSICK
Model IdentifierUM30-21211B
Official Part Number6068448

Technical Overview

The SICK UM30-21211B uses ultrasonic echoes to detect reflecting objects over a 65–350 mm operating range, with a separate 600 mm limiting range. IO-Link V1.1 supports process data, diagnosis, parameterization and data storage; one push-pull PNP/NPN output provides the configured switching result. Local display controls support teach-in, while adjustable filters and switching-point, window and background modes adapt detection. Response is 64 ms, switching frequency 12 Hz and output time 16 ms. Internal temperature compensation reaches its optimum after approximately 30 minutes. MF synchronization and multiplexing support up to 50 interconnected sensors outside IO-Link mode. The M30 threaded housing has an M12 five-pin connector and IP65/IP67 protection.

65–350 mm ultrasonic sensor with IO-Link V1.1, one push-pull PNP/NPN output rated ≤100 mA, local display and M12 five-pin connection.

Key Features

  • 65–350 mm operating range; 600 mm limiting range
  • IO-Link V1.1: process data, diagnosis, parameterization and data storage
  • One push-pull PNP/NPN digital output; maximum current ≤100 mA
  • 64 ms response; 12 Hz switching; 16 ms output time
  • Switching-point, window and background modes; invertible output
  • Local numeric/teach-in settings; teach buttons can be deactivated
  • Temperature compensation; optimum after approximately 30 minutes
  • MF synchronization/multiplexing up to 50 sensors; unavailable in IO-Link mode
  • 9–30 V DC; ≤2.4 W without load; startup <300 ms
  • LED display and two status LEDs; M30 thread; M12 five-pin; IP65/IP67

Bring ultrasonic process data and parameter settings into IO-Link control while retaining local display adjustment.

Technical Specification Matrix

ParameterValue
Functional principleUltrasonic object/distance detection with IO-Link
Operating range65–350 mm
Limiting range600 mm; distinct from operating range
Detection areaDepends on reflection, size and target alignment; validate the actual target and mounting geometry
Resolution≥0.18 mm
Repeatability±0.15% of current measured value; minimum value ≥resolution
Measurement accuracy±1% of current measured value
Temperature compensationAvailable; can be disabled; optimum after approximately 30 min
Uncompensated temperature drift0.17%/K with temperature compensation disabled
Response time64 ms
Switching frequency12 Hz
Output time16 ms
Ultrasonic frequencyTypical 400 kHz; acoustic frequency
Digital output1 × push-pull PNP/NPN; maximum output current ≤100 mA
Switching modesSwitching point (DtO), window, object between sensor and background (ObSB)
Hysteresis5 mm; configurable using Connect+
AdjustmentLocal teach-in and numeric settings; output inversion, on delay and measurement filters; teach-button deactivation and factory reset
Synchronization and multiplexingNot available in IO-Link mode; otherwise via MF pin 5, up to 50 interconnected sensors; multiplexing requires distinct addresses
Multifunction input1 × MF
Multiple-sensor separationWithout synchronization/multiplexing: parallel >40 cm; opposite >250 cm
Power supply9–30 V DC; limit values; reverse-polarity protected
Supply network requirementShort-circuit protected network, maximum 8 A, Class 2
Power consumption≤2.4 W without load
Initialization time<300 ms
Indicators and controlsLED display, 2 status LEDs and T1/T2 controls; display can be deactivated
ConnectionM12 five-pin male connector
Pin assignment1 BN=L+; 3 BU=M/0 V; 4 BK=Q/inverted Q/C (IO-Link); 2 WH=not connected; 5 GY=Sync/Multi and Connect+ communication
Mounting threadM30 × 1.5
Mounting nuts36 mm across flats; maximum tightening torque 40 Nm
Sending axisStraight
Housing materialsNickel-plated brass and PBT; display TPU
Transducer materialsPolyurethane foam and glass epoxy resin
IP ratingIP65/IP67
Protection classIII
Operating temperature−25 to +70 °C
Storage temperature−40 to +85 °C
Physical Weight (kg)0.15
IO-LinkV1.1; process data, diagnosis, parameterization and data storage

Industrial Applications

1. Monitoring material level in a large vessel

A vessel can present a sufficiently reflecting material surface within the 65–350 mm operating range. The sensor is aligned to the surface, and its local controls teach the required distance condition. External level control evaluates the push-pull switching result after checking actual material echoes, temperature stabilization and the 64 ms response against the filling cycle.

Problem Solved

A taught surface-distance condition gives external filling control a repeatable process threshold, helping it recognize when the material surface reaches the selected level without contacting the material.

Material level Taught thresholds External filling control

2. Checking the position of a large load face

A handling station can present a reflecting load face within the 65–350 mm operating range and configure an acceptance window using the local display and controls. External sequence control interprets the selected push-pull output condition before the next transfer step. Actual target alignment, window boundaries and return strength are validated, and the configured measurement filters are matched to the presentation cycle.

Problem Solved

A distance window provides external handling control with a selected acceptance zone for a large load face, helping it recognize an object placed too near or too far before transfer.

Load face Acceptance window Local settings

3. Loading sensor settings for a changed process recipe

A machine with a compatible IO-Link master can use the sensor IO-Link V1.1 interface for parameterization, process data and diagnosis. External machine control selects the sensor configuration appropriate to the next reflecting target and validates the actual distance condition within the 65–350 mm operating range. Data storage supports the configuration workflow, while synchronization and multiplexing are excluded during IO-Link operation.

Problem Solved

Remote access to parameters and diagnostic information gives external machine control a practical way to manage sensor settings during process changes, helping reduce repeated local adjustment at the sensing position.

IO-Link V1.1 Recipe settings Diagnostic access
Select your currency