DS50-P1112 Mid Range Distance Sensors – SICK Sensor
$ 455.84
SKU: SICK 1047402
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1047402
Distance Sensor Model: DS50-P1112
OEM Spec Ref
Mechanics/electronics
Supply voltage Vs | DC 10 V … 30 V 1) |
Ripple | ≤ 5 Vpp 2) |
Power consumption | ≤ 1.85 W 3) |
Initialization time | ≤ 350 ms |
Warm-up time | ≤ 15 min |
Housing material | Metal (zinc diecast) |
Window material | Plastic (PMMA) |
Connection type | Male connector, M12, 5-pin |
Indication | LC display, 2 x LED |
Weight | 200 g |
Dimensions (W x H x D) | 36.1 mm x 62.7 mm x 57.7 mm |
Enclosure rating | IP65 |
Protection class | III |
- 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
- 2) May not fall short of or exceed VS tolerances.
- 3) Without load.
Performance
Measuring range | 200 mm … 10,000 mm, 90 % remission
200 mm … 6,000 mm, 18 % remission 200 mm … 4,000 mm, 6 % remission |
Target | Natural objects |
Resolution | 1 mm 1) |
Repeatability | ≥ 2.5 mm 2) 3) 4) |
Accuracy | ± 10 mm 1) 5) |
Response time | 10 ms … 50 ms, 10 ms / 50 ms 4) |
Switching frequency | 50 Hz / 10 Hz 4) |
Light source | Laser, red visible red light |
Laser class | 2 (IEC 60825-1:2014, EN 60825-1:2014) 6) |
Typ. light spot size (distance) | 15 mm x 15 mm (10 m) |
Additional function | Set moving average: fast/slow, adjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in, scaling and inversion of digital output, set hysteresis, Multifunctional input: laser off / external teach / deactivated, Unique measurement value, crosstalk safety, switch-off display, reset to factory default, lock user interface |
Average laser service life (at 25 °C) | 100,000 h |
- 1) Related to distance value on the display.
- 2) Equivalent to 1 σ.
- 3) 6 % … 90 % remission.
- 4) Dependent on the averaging setting: fast/slow.
- 5) 90 % remission.
- 6) Wavelength: 658 nm; max. output: 180 mW; pulse duration: 5 ns; duty cycle: 1/200.
Interfaces
|
|||||||||
Multifunctional input (MF) | 1 x 3) 4) | ||||||||
Hysteresis | 1 mm … 9,999 mm |
- 1) Output Q short-circuit protected.
- 2) PNP: HIGH = VS – (< 2.5 V) / LOW = 0 V.
- 3) Response time ≤ 60 ms.
- 4) PNP: HIGH = VS / LOW = ≤ 2.5 V.
Ambient data
Ambient temperature, operation | –30 °C … +65 °C
–30 °C … +80 °C, operation with 2 cooling plates –30 °C … +140 °C, operation with 2 cooling plates and protection filter |
Ambient temperature, storage | –40 °C … +75 °C |
Max. rel. humidity (not condensing) | ≤ 95 % |
Typ. Ambient light immunity | 40,000 lx |
Vibration resistance | EN 60068-2-6, EN 60068-2-64 |