OD1-B035C15I25 Displacement Measurement Sensors – SICK Sensor

$ 1,407.56

SKU: SICK 6050524

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6050524
Distance Sensor Model: OD1-B035C15I25
OEM Spec Ref 

Mechanics/electronics

Supply voltage Vs DC 12 V (–5 %) … DC 24 V (+10 %)
Power consumption ≤ 1.92 W 1)
Warm-up time ≤ 5 min
Housing material Metal (Aluminum)
Window material Plastic (PPSU)
Connection type Cable with male connector, M12, 5-pin, 30 cm
Indication 4-digit 7-segment display (plus 4 LEDs for status display)
Control elements 4 buttons
Weight 40 g
Dimensions (W x H x D) 17.8 mm x 44.4 mm x 31 mm
Enclosure rating IP67
Protection class III
  • 1) Without load, with current output.

 

Performance

Measuring range 20 mm … 50 mm
Target Natural objects
Repeatability 6 µm 1) 2)
Linearity ± 30 µm 3)
Response time ≥ 2 ms 4)
Measuring frequency ≤ 2 kHz
Output time ≥ 0.5 ms
Light source Laser, red
visible red light
Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014) 5)
Typ. light spot size (distance) 800 µm x 450 µm (35 mm)
Additional function Averaging 1 … 512x, automatic or manual sensitivity adjustment, Analog outputs can be taught in, digital outputs can be taught in, invertable digital output, switching mode: window (Wnd), switching mode: distance to object (DtO), switiching mode: object between sensor and background (ObSB), multifunctional input: laser-off / external teach-in / trigger
  • 1) Averaging function set to: 512.
  • 2) Constant ambient conditions.
  • 3) Measurement on 90 % remission (ceramic, white).
  • 4) With fixed sensitivity adjustment and averaging setting = 1. With automatic sensitivity and measuring rate 500 µs: 2 … 7.5 ms response time/measuring rate 1,000 µs: 4 … 15 ms response time.
  • 5) Wavelength: 655 nm, max. output: 390 µW (laser class 1) / < 1 mW (laser class 2).

 

Interfaces

Digital output
Number 1
Type PNP/NPN, selectable
Analog output
Number 1
Type Current output
Current 4 mA … 20 mA, ≤ 300 Ω
Resolution 13.4 bit
Multifunctional input (MF) 1 x 1)
  • 1) MF can be used as laser-off, trigger, external teach-in or deactivated.

 

Ambient data

Ambient temperature, operation –10 °C … +50 °C
Ambient temperature, storage –20 °C … +60 °C
Min. rel. humidity (not condensing) 35 %
Max. rel. humidity (not condensing) 95 %
Temperature drift ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor)
Typ. Ambient light immunity Artificial light: ≤ 3,000 lx

Sunlight: ≤ 10,000 lx

Vibration resistance 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
Shock resistance 50 G (x, y, z axis 3 times each)