OD1-B035H15I25 Displacement Measurement Sensors – SICK Sensor
$ 1,313.18
SKU: SICK 6050504
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 6050504
Distance Sensor Model: OD1-B035H15I25
OEM Spec Ref
Mechanics/electronics
Supply voltage Vs | DC 12 V (–5 %) … DC 24 V (+10 %) |
Power consumption | ≤ 1.92 W 1) |
Warm-up time | ≤ 5 min |
Housing material | Stainless steel |
Window material | Plastic (PPSU) |
Connection type | Cable with male connector, M12, 5-pin, 30 cm |
Indication | 4-digit 7-segment display (plus 4 LEDs for status display) |
Control elements | 4 buttons |
Weight | 70 g |
Dimensions (W x H x D) | 17.8 mm x 44.4 mm x 31 mm |
Enclosure rating | IP67 |
Protection class | III |
- 1) Without load, with current output.
Performance
Measuring range | 20 mm … 50 mm |
Target | Natural objects |
Repeatability | 6 µm 1) 2) |
Linearity | ± 30 µm 3) |
Response time | ≥ 2 ms 4) |
Measuring frequency | ≤ 2 kHz |
Output time | ≥ 0.5 ms |
Light source | Laser, red visible red light |
Laser class | 1 (IEC 60825-1:2014, EN 60825-1:2014) 5) |
Typ. light spot size (distance) | 800 µm x 450 µm (35 mm) |
Additional function | Averaging 1 … 512x, automatic or manual sensitivity adjustment, Analog outputs can be taught in, digital outputs can be taught in, invertable digital output, switching mode: window (Wnd), switching mode: distance to object (DtO), switiching mode: object between sensor and background (ObSB), multifunctional input: laser-off / external teach-in / trigger |
- 1) Averaging function set to: 512.
- 2) Constant ambient conditions.
- 3) Measurement on 90 % remission (ceramic, white).
- 4) With fixed sensitivity adjustment and averaging setting = 1. With automatic sensitivity and measuring rate 500 µs: 2 … 7.5 ms response time/measuring rate 1,000 µs: 4 … 15 ms response time.
- 5) Wavelength: 655 nm, max. output: 390 µW (laser class 1) / < 1 mW (laser class 2).
Interfaces
|
|||||||||||
|
|||||||||||
Multifunctional input (MF) | 1 x 1) |
- 1) MF can be used as laser-off, trigger, external teach-in or deactivated.
Ambient data
Ambient temperature, operation | –10 °C … +50 °C |
Ambient temperature, storage | –20 °C … +60 °C |
Min. rel. humidity (not condensing) | 35 % |
Max. rel. humidity (not condensing) | 95 % |
Temperature drift | ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor) |
Typ. Ambient light immunity | Artificial light: ≤ 3,000 lx
Sunlight: ≤ 10,000 lx |
Vibration resistance | 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
Shock resistance | 50 G (x, y, z axis 3 times each) |