SICK 6050138 IMP14-03BPOVC0S PNP NC Inductive Sensor

SICK 6050138 IMP14-03BPOVC0S PNP NC Inductive Sensor

USD 287.82

M14 flush inductive sensor with 3 mm nominal range, PNP NC output, pressure resistance to 500 bar, 500 Hz switching and M12 four-pin connector.

SKU: SICK-6050138 Category:
SICK IMP

SICK IMP14-03BPOVC0S Pressure-Resistant Inductive Sensor

BrandSICK
Model IdentifierIMP14-03BPOVC0S
Official Part Number6050138

Technical Overview

The SICK IMP14-03BPOVC0S is a flush M14 inductive proximity sensor designed for hydraulic applications with pressure resistance up to 500 bar. Its PNP normally-closed output detects qualified metal targets at a nominal range of 3 mm and an assured range of 2.4 mm. Target material matters: the listed reduction factors are approximately zero for aluminum and copper. The sensor operates from 10–30 V DC, switches at 500 Hz and becomes available within 50 ms. A stainless-steel 316L housing, zirconium-dioxide ceramic sensing face and NBR sealing ring support pressure-side integration. The sensing face carries the IP68 rating. Connection uses an M12 four-pin male connector, with the NC output on pin 2.

Pressure-resistant M14 flush inductive sensor with 3/2.4 mm nominal/assured ranges, PNP NC output, 500 Hz switching and M12 four-pin connector.

Key Features

  • M14 ×1.5 threaded housing; flush installation
  • 3 mm nominal sensing range; 2.4 mm assured range
  • Pressure resistance ≤500 bar for hydraulic applications
  • PNP normally-closed output on pin2; DC three-wire circuit
  • 10–30 V DC supply; continuous output current ≤200 mA
  • 500 Hz switching; availability ≤50 ms
  • Stainless steel316L housing; zirconium-dioxide ceramic sensing face
  • NBR sealing ring;11.5 ×2.0 mm large sealing ring
  • IP68 at sensing face; −25 to +80 °C operation
  • M12 four-pin male connector; short-circuit protection

Monitor qualified metal targets in hydraulic equipment with pressure resistance up to 500 bar and a PNP normally-closed signal.

Technical Specification Matrix

ParameterValue
Functional principleInductive metal proximity detection
Housing formMetric cylindrical
Housing threadM14 ×1.5
Body diameter14 mm
Pressure resistance≤500 bar
Sensing range Sn3 mm nominal
Assured sensing range Sa2.4 mm
InstallationFlush
Switching outputPNP
Output functionNormally-closed (NC)
Electrical wiringDC three-wire
Switching frequency500 Hz
ConnectionM12 four-pin male connector
Pin assignment1/BN=L+; 3/BU=M; 2/WH=NC output; 4/BK=not connected; CD-008
Power supply10–30 V DC
Ripple≤20% of supply voltage
Voltage drop≤2 V with output current200 mA
Time delay before availability≤50 ms
Hysteresis1–15%; typical8%
Reproducibility≤4% at supply20–30 V DC and ambient23 °C ±5 °C
Temperature drift15% of Sr
EMCEN60947-5-2; IEC61000-4-4 test1 kV
Continuous current≤200 mA
Vacuum resistance10⁻⁸ Torr at front
Large sealing ring11.5 ×2.0 mm
Short-circuit protectionProvided
Shock resistance30 g,11 ms
Vibration resistance10–55 Hz,1 mm
Operating temperature−25 to +80 °C
Housing materialStainless steel V4A,DIN1.4404/AISI316L
Sensing face materialZirconium dioxide ceramic,ZrO2
Sealing ring materialNBR
Housing length65 mm
Thread length11 mm
Maximum tightening torque≤70 Nm
IP ratingIP68 at sensing face
Wrench width across flats19 mm
MTTFD156 years
Diagnostic coverage DCavg0%
Mission time20 years
Target-material reduction factorsReference values that may vary: St37 steel=1; V2A/304≈0.85; aluminum≈0; copper≈0; brass≈0.15
Mounting clearancesB=12 mm; C=14 mm; D=9 mm; F=20 mm; follow exact manufacturer installation drawing

Industrial Applications

1. Monitoring a steel piston feature in hydraulic equipment

A hydraulic assembly can present a qualified steel piston feature to the pressure-side sensing face at a defined travel position. The 3 mm nominal and 2.4 mm assured ranges guide target placement with flush mounting. The external controller evaluates the PNP normally-closed output, while the mechanical installation remains within the documented pressure and sealing requirements.

Problem Solved

A noncontact steel-position condition supplies the external hydraulic sequence with a local travel reference without requiring a mechanical sensing lever to contact the monitored piston feature during repeated motion.

Hydraulic position ≤500 bar PNP NC

2. Checking a steel component in a pressure fixture

A pressure fixture can bring a qualified steel component into the local detection zone before its external control sequence advances. The normally-closed PNP output provides a presence condition. The stainless-steel housing, ceramic sensing face and NBR sealing ring support integration at the monitored pressure boundary, subject to the exact installation drawing and pressure limit.

Problem Solved

A local steel-presence condition helps external sequence control identify an empty monitored fixture position without an optical surface mark or a contact probe pressing against the component.

Steel presence Pressure fixture Ceramic face

3. Counting separated steel trigger features

A mechanism can move separated qualified steel trigger features through the sensing zone and route PNP switching transitions to compatible external counting equipment. Feature spacing and event rate remain within the 500 Hz switching frequency. The connected input operates from the specified DC supply and within the 200 mA continuous-current limit.

Problem Solved

A qualified steel-feature passage event supports cycle or throughput tracking without a mechanical counting arm, while external equipment performs the count and coordinates the monitored mechanism.

Steel-feature counting 500 Hz PNP output
Select your currency