CM30-25NNP-EW1 Capacitive Proximity Sensors – SICK Sensor

$ 110.44

SKU: SICK 6058158

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6058158
Capacitive Proximity Sensor Model: CM30-25NNP-EW1
OEM Spec Ref 

Features

Housing Cylindrical thread design
Thread size M30 x 1.5
Diameter Ø 30 mm
Sensing range Sn 4 mm … 25 mm
Safe sensing range Sa 19.13 mm 1)
Installation type Non-flush
Switching frequency 50 Hz
Connection type Cable, 4-wire, 2 m 2)
Switching output NPN
Output function Complementary
Output characteristic Wire configurable
Electrical wiring DC 4-wire
Adjustment Potentiometer (Sensitivity)
Enclosure rating IP68, IP69K 3)
Authorizations Ecolab 4)

CE-conformity

cULus

  • 1) For flush mounting in electrically conductive materials Sa = 0.8 x Sr at temperatures <0 °C and >60 °C.
  • 2) Do not bend below 0 °C.
  • 3) 1 m water depth / 60 min.
  • 4) P3-topax 19, P3-topax 56, P3-topax 66, P3-topactive DES.

 

Mechanics/electronics

Supply voltage 10 V DC … 36 V DC
Ripple ≤ 10 % 1)
Voltage drop ≤ 2 V DC 2)
Current consumption 12 mA 3)
Time delay before availability ≤ 200 ms
Hysteresis 3 % … 20 %
Reproducibility ≤ 5 % 4) 5)
Temperature drift (of Sr) ± 10 %
EMC According to EN 60947-5-2
Continuous current Ia ≤ 200 mA
Cable material PVC
Conductor size 0.34 mm²
Cable diameter Ø 5.2 mm
Short-circuit protection
Reverse polarity protection
Power-up pulse protection
Shock and vibration resistance According to EN 60068
Ambient operating temperature –30 °C … +85 °C 6)
Ambient temperature, storage –40 °C … +85 °C
Housing material Plastic, PBT
Housing length 81 mm
Thread length 45.5 mm
Tightening torque, max. ≤ 7.5 Nm
Items supplied Mounting nut, PA12 plastic (2x)

Screwdriver for potentiometer adjustment (1 x)

UL File No. NRKH.E191603
  • 1) Of Ub.
  • 2) At Ia max.
  • 3) Without load.
  • 4) Of Sr.
  • 5) Ub and Ta constant.
  • 6) +120 °C short time, at the front of the sensor.

 

Safety-related parameters

MTTFD 919 years
DCavg 0 %
TM (mission time) 20 years

Reduction factors

Note The values are reference values which may vary
Metal 1
Water 1
PVC Approx. 0.4
Oil Approx. 0.25
Glass 0.6
Ceramics 0.5
Alcohol 0.7
Wood 0.2 … 0.7