SICK 6030133 CQ28-10NNP-KW1 Capacitive Proximity Sensor

SICK 6030133 CQ28-10NNP-KW1 Capacitive Proximity Sensor

USD 156.52

CQ28-10NNP-KW1 offers capacitive sensing, NPN output with selectable NC or NO, local and external teach-in, 10 Hz switching and IP68 protection.

SKU: SICK-6030133 Category:
SICK CQ

SICK CQ28-10NNP-KW1 Capacitive Proximity Sensor

BrandSICK
Model IdentifierCQ28-10NNP-KW1
Official Part Number6030133

Technical Overview

The SICK CQ28-10NNP-KW1 is a rectangular capacitive proximity sensor with a NPN with selectable NC or NO function output. It detects changes in capacitance caused by nearby material, supporting qualified detection of metal and nonmetal targets. Its specified sensing range is 1–10 mm non-flush; actual reach depends on the material and installation. A teach-in button and external teach wire sets sensitivity for the application. The sensor operates from 10–30 V DC with 10 Hz switching and connects through a 2 m four-wire PVC cable. Its PBT housing provides IP68 protection according to EN 60529. Material reduction factors and an empty/full or target/background test guide commissioning.

Capacitive proximity sensor with NPN with selectable NC or NO function output, 1–10 mm non-flush sensing, teach-in button and external teach wire and 2 m four-wire PVC cable.

Key Features

  • Rectangular capacitive proximity sensing for qualified metal and nonmetal targets
  • 1–10 mm non-flush specified sensing range
  • NPN with selectable NC or NO function output
  • Teach-in button and external teach wire
  • 10–30 V DC operating supply
  • 10 Hz switching
  • 2 m four-wire pvc cable
  • IP68 according to EN 60529; PBT housing
  • Material-dependent sensing distance; reference reduction factors documented

Detect qualified metal or nonmetal material with adjustable capacitive sensing and a discrete switching signal for machine control.

Technical Specification Matrix

ParameterValue
Functional principleCapacitive proximity sensing
Housing designRectangular
Sensing range1–10 mm non-flush
Assured sensing distance7.2 mm
InstallationNon-flush
Material reduction factorsReference values, material dependent: metal 1; water 1; PVC approximately 0.4; oil approximately 0.25; glass 0.6; ceramics 0.5; alcohol 0.7; wood 0.2–0.7
AdjustmentTeach-in button and external teach wire
Switching outputNpn with selectable nc or no function
Electrical wiringDC, 4-wire
Switching frequency10 Hz
Power supply10–30 V DC
Residual ripple≤10%
Voltage drop≤2.5 V DC at maximum output current
Current consumption12 mA without load
Initialization time≤300 ms
Output current≤200 mA
Reproducibility≤5% of sensing range at constant supply voltage and ambient temperature
Temperature drift±10% of sensing range
Short-circuit protectionYes
Connection2 m four-wire pvc cable
Cable materialPVC; do not bend below 0 °C
Housing materialPBT plastic
Sensing face materialPlastic
IP ratingIP68 according to EN 60529
Operating temperature−20 to +85 °C
Shock resistance30 g for 11 ms
Vibration resistance10–55 Hz at 1 mm amplitude
EMCEN 60947-5-2
MTTFD1,112 years
Diagnostic coverage DCavg0%
Mission time20 years
UL fileNRKH.E191603
Storage temperature−40 to +85 °C
Housing height46 mm
Housing depth5.5 mm
Conductor cross-section0.14 mm²
Pin assignment1/BN: L+; 2/WH: Teach; 4/BK: Q; 3/BU: M
IndicatorsGreen and yellow LEDs
EMC integration noteConducted interference in the oscillator frequency range may change the output signal; observe manufacturer operating instructions

Industrial Applications

1. Checking a nonmetal part in an assembly fixture

An assembly fixture can place a qualified nonmetal part near the sensing face and use the NPN with selectable NC or NO function signal to confirm its local presence. The teach-in button and external teach wire adapts sensitivity to the actual target and surrounding fixture. Commissioning compares empty and occupied states at the installed spacing, taking the documented material reduction factors into account.

Problem Solved

A local presence signal helps the controller detect a missing part before the next assembly step, without requiring a metal target on the component or a contact actuator.

Part presence Nonmetal targets Capacitive sensing

2. Detecting a liquid at a point in a nonmetal vessel

A suitable nonmetal vessel can position the sensor outside its wall at the desired detection point. After testing the actual wall, liquid and spacing, the teach-in button and external teach wire sets a threshold between empty and filled conditions. The NPN with selectable NC or NO function output provides a discrete point-level event to a compatible controller; the specified range remains subject to the installed materials.

Problem Solved

A qualified external point-level signal helps the process controller identify liquid reaching the monitored height while avoiding a probe inside the vessel and preserving the vessel wall.

Point level External mounting Qualified vessel wall

3. Monitoring granulate at a feed inspection window

A granulate feeder can place the sensor beside a suitable nonmetal inspection window to check whether material occupies the monitored location. The teach-in button and external teach wire is set using the actual granulate, window and installation spacing. Empty and filled tests, including expected moisture and buildup conditions, qualify the discrete output before it is used to coordinate feeding.

Problem Solved

A local material-presence event helps the controller identify an empty feed location or arrival of replenishment material, supporting feed sequencing without placing a mechanical paddle in the granulate.

Granulate feed Material presence Threshold setup
Select your currency